Solaris10与EMCCX310c实现FCSAN实施手册V2.doc
《Solaris10与EMCCX310c实现FCSAN实施手册V2.doc》由会员分享,可在线阅读,更多相关《Solaris10与EMCCX310c实现FCSAN实施手册V2.doc(26页珍藏版)》请在三一文库上搜索。
1、Solaris 10与EMC CX3-10c实现FC-SAN实施手册现场背景:服务器3台,2台Sun Fire V490,1台Sun Fire V250。存储为DELL|EMC CX3-10c,配备8TB硬盘,一台Brocade SW200E光纤交换机。目的:实现FC-SAN构架。拓扑图:实施步骤:1、 先完成Dell|EMC CX3-10c初始化,配置两个管理IP,分别为:XX.XX.XX.XX。2、 建立服务器、光纤交换机、存储之间的链路。3、 初始化光纤交换机,配置管理地址:XX.XX.XX.XX4、 在Navisphere Manager管理界面发现链路。5、 在服务器端安装Navis
2、phere agent注册,安装PowerPath多链路管理软件。具体安装操作如下:l Navisphere agent的安装与配置先将光盘mount上后,再执行下面的命令:pkgadd -d NAVIAGNT.pkg会出现下述提示信息,按照提示信息选择安装即可。Select the packages that you want to install by doing one of thefollowing:? Enter 1 (to install the host agent)or? Enter 2 (to install CLI) or Enter All (to install bot
3、h the host agentand CLI)Enter y and y to begin the installation.The installation program looks for any agent configuration filesyou may already have on your system. If the program doesnot find any agent configuration files, then you have finishedinstalling the agent; go to step 10q. If the program d
4、oes find anyexisting configuration files, it displays a message like the following:At Least 1 saved config file exists for NavisphereAgent.Please select 1 of the following:1Restore/etc/Navisphere/.Naviagent-config.000120:10592Restore/etc/Navisphere/.Naviagent-config.000121:14083 QuitSelect number 1
5、- 3.修改agent.config配置文件,主要方法如下:修改/etc/Navisphere/agent.configVi /etc/Navisphere/agent.config 修改内容为:# Navisphere agent.config# -# This file is used by Navisphere Agent to configure# site specific values.# All entries in this file have this form:# object value-list# Where object tells what sort of info
6、rmation is to# be configured, and value-list is a# whitespace-separated list of values to be configured.# Samples, which should be edited, appear below for all# permissible types of objects.# White space (tabs, space, line-feeds,# carriage-returns) and blank lines are ignored;# To continue a line on
7、to the next line, use as the# last character of that line. The is dropped when# the next line is concatenated to the continued line.# Description specification# -# The clarDescr object takes arbitrary text values# intended to describe the agent and its location.#clarDescr Navisphere Agent# The clarC
8、ontact object takes arbitrary text values# intended to describe who is responsible for the# configured agent, and how to reach them.#clarContact John Smith, 800-555-1212# Device specification.# -# The format of device objects for CLARiiON devices# is:# devicedevice-specname description# where the de
9、vice-specification is the device name to# open to access the CLARiiON device. It can be a# SCSI-2 file name. If this is auto, all attached# arrays with bound LUNs will be automatically# configured. (Currently, dummy arguments are required# for name and description, when using# auto-configuration.) T
10、his can NOT be defaulted.# The name is the per CLARiiON name that can be used to# identify each CLARiiON to the manager application.# The name is REQUIRED and cannot contain spaces (even# if surrounded by quotes). This can NOT be defaulted.# The description is a quoted string that contains a# brief
11、description of the CLARiiON chassis being# managed. It defaults to if not specified, and to# the device name for auto-configuration.# SAMPLES:# device c0t0d0 NAVISPHERE-1 NAVISPHERE-1# automatically detect manageable devicesdevice auto auto# User Specification.# -# The format of user objects is# use
12、r localUserId# OR# user userIdhostname在此处添加存储系统SPA和SPB管理地址即可user systemXX.XX.XX.XX user systemXX.XX.XX.XX# These build a list of users who are allowed to perform# WRITE operations to the CLARiiON devices managed by# this agent. By default, as specified below, only root# on this machine has WRITE acc
13、ess. Others can be# granted access by including their login name and host# which they can access from. A null list prevents# anyone, including admin, from having write access. In# order to get write access, this file would have to be# modified and the Agent stopped and restarted to# re-read the conf
14、iguration file, or an appropriate# remote configuration file would have to be sent to the# agent from an already-priviledged user.user root # only on this machine#user sbluepicasso # individual user sblue on# host picasso#user lgreenhannibal # individual user lgreen on# host hannibal# Poll specifica
15、tion# -# The poll object takes a numerical count of seconds.# This specifies how often the agent solicits# information from the array, rather than using cached# information. The minimum is 10.#poll 60# Eventlog specification# -# The eventlog object takes a numerical count of log# entries.# This defi
16、nes the maximum number of SP log events# received by the agent on startup, and received by# clients per poll. A value of 0 causes the devices# entire log to be read at startup. A minimum of 100# events will be read on serial, and 2048 on fibre,# overriding any lower value configured below.#eventlog
17、100# Baud Rate specification# -# If the agent is using a serial port to manage a# device, the next entry can specify either 9600 baud# or 19200 baud.#baud 9600# end of configuration file#保存配置文件,然后可以启动/停止agent服务。命令如下:bash3.00#/etc/init.d/agent stopbash3.00#/etc/init.d/agent start如果安装配置正常,启动agent服务后在N
18、avisphere Manager管理界面中的Connective中会看到链路状态register为yes。如register显示为no,可以考虑重启服务器或者重启agent服务,或者在Navisphere Manager界面中进行手动注册也可以。注册完成后会在链路状态中显示主机名称等信息。l PowerPath的安装与注册PowerPath的安装1、Mount CDROM2、bash3.00# mkdir /unload3、bash3.00#cd /unload4、bash3.00#cp /. 从光盘将安装文件拷贝到新建的目录下面。5、bash3.00# gunzip 解压缩文件6、bash
19、3.00# tar -xvf 解压缩文件7、bash3.00#pkgadd d . 安装PowerPath按照下述提示操作:SPARC host:The following packages are available:EMCpower EMC PowerPath(sparc) 5.2.x_bxxxSelect package(s) you wish to process (or all toprocess all packages). (default: all) ?,?,q:x86 (i386) host:The following packages are available:EMCpo
- 配套讲稿: