1、- - This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 January 2010 - - EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 1822-4 November 2009 ICS 13.040.40 Supersedes EN 1822-4:2000 English Version High efficiency air filters (EPA, HEPA a
2、nd ULPA) - Part 4: Determining leakage of filter elements (scan method) Filtres air haute efficacit (EPA, HEPA et ULPA) - Partie 4: Essais dtanchit de llment filtrant (mthode dexploration) Schwebstofffilter (EPA, HEPA und ULPA) - Teil 4: Leckprfung des Filterelementes (Scan-Verfahren) This European
3、Standard was approved by CEN on 17 October 2009. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concer
4、ning such national standards may be obtained on application to the CEN Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own
5、 language and notified to the CEN Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuan
6、ia, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2009 CEN
7、 All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 1822-4:2009: E - - EN 1822-4:2009 (E) 2 Contents Page Foreword 4 Introduction 5 1Scope .6 2Normative references .6 3Terms and definitions 6 4Description of the procedure 7 5Test filter 8
8、 6Test apparatus 8 6.1Set-up of the test apparatus 8 6.2Test duct . 11 6.2.1Test air conditioning . 11 6.2.2Adjustment of the volume flow rate . 11 6.2.3Measurement of the volume flow rate . 11 6.2.4Aerosol mixing duct 11 6.2.5Test filter mounting assembly 11 6.2.6Measuring points for the pressure d
9、ifference 11 6.2.7Sampling, upstream 11 6.2.8Screening . 12 6.3Scanning assembly . 12 6.3.1General . 12 6.3.2Sampling, downstream . 12 6.3.3Probe arm . 13 6.3.4Aerosol transport lines . 13 6.3.5Provisions to move the probe 13 6.4Aerosol generation and measurement techniques 13 6.4.1General . 13 6.4.
10、2Set-up for testing with a monodisperse test aerosol . 14 6.4.3Set-up for testing with a polydisperse test aerosol . 14 7Test air 14 8Test procedure . 15 8.1General . 15 8.2Preparatory checks . 15 8.3Starting up the aerosol generator 16 8.4Preparing the test filter . 16 8.4.1Installing the test filt
11、er 16 8.4.2Flushing the test filter . 16 8.5Testing 16 8.5.1Measuring the pressure drop . 16 8.5.2Testing with monodisperse test aerosol . 17 8.5.3Testing with polydisperse test aerosol . 17 8.5.4Leak testing (local penetration) . 17 8.5.5Determining the mean efficiency of the filter element . 17 9E
12、valuation . 18 9.1Calculating the penetration and the efficiency . 18 9.2Local penetration . 19 9.3Mean efficiency 20 - - EN 1822-4:2009 (E) 3 9.4Classification 20 10Test report . 20 11Maintenance and inspection of the test apparatus . 21 Annex A (normative) Oil Thread Leak Test . 23 Annex B (normat
13、ive) Determining the test parameters . 24 B.1General 24 B.2Boundary conditions 24 B.3Test filter data . 24 B.4Data for the apparatus . 25 B.4.1Particle counters 25 B.4.2Downstream sampling probes 25 B.4.3Loss factor 26 B.5Sequence of calculation steps 26 B.6Checking the isokinetic sampling 27 B.7Cho
14、osing the probe speed 28 B.8Minimum aerosol concentration . 29 B.9Maximum aerosol concentration 30 B.10Leak signal 31 B.10.1 Effective value 31 B.10.2 Signal difference . 32 Annex C (informative) Example of an application with evaluation . 34 Annex D (informative) Leak Test with solid PSL Aerosol 37
15、 D.1Background . 37 D.2General Remarks 37 D.3Test Procedure . 37 D.4Test Protocol . 39 Annex E (informative) 0,3 m 0,5 m Particle Efficiency Leak Test 40 Bibliography . 42 - - EN 1822-4:2009 (E) 4 Foreword This document (EN 1822-4:2009) has been prepared by Technical Committee CEN/TC 195 “Air filter
16、s for general air cleaning”, the secretariat of which is held by UNI. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by May 2010, and conflicting national standards shall be withdrawn at the latest
17、by May 2010. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 1822-4:2000. It contains requirements, fundam
18、ental principles of testing and the marking for efficient particulate air filters (EPA), high efficiency particulate air filters (HEPA) and ultra low penetration air filters (ULPA). The complete European Standard EN 1822, High efficiency air filters (EPA, HEPA and ULPA) will consist of the following
19、 parts: Part 1: Classification, performance testing, marking Part 2: Aerosol production, measuring equipment, particle counting statistics Part 3: Testing flat sheet filter media Part 4: Determining leakage of filter elements (scan method) Part 5 : Determining the efficiency of filter elements Accor
20、ding to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvi
21、a, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. - - EN 1822-4:2009 (E) 5 Introduction As decided by CEN/TC 195, this European Standard is based on particle counting methods which actually cover mo
22、st needs of different applications. The difference between this European Standard and previous national standards lies in the technique used for the determination of the integral efficiency. Instead of mass relationships, this technique is based on particle counting at the most penetrating particle
23、size (MPPS), which is for micro-glass filter mediums usually in the range of 0,12 m to 0,25 m. This method also allows to test ultra low penetration air filters, which was not possible with the previous test methods because of their inadequate sensitivity. For Membrane and synthetic filter media, se