BS EN 50131-8-2009 Alarm systems — Intrusion and hold-up systems — Part 8 Security fog devicesystems.pdf
《BS EN 50131-8-2009 Alarm systems — Intrusion and hold-up systems — Part 8 Security fog devicesystems.pdf》由会员分享,可在线阅读,更多相关《BS EN 50131-8-2009 Alarm systems — Intrusion and hold-up systems — Part 8 Security fog devicesystems.pdf(28页珍藏版)》请在三一文库上搜索。
1、raising standards worldwide NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW BSI British Standards Alarm systems Intrusion and hold-up systems Part 8: Security fog device/systems BS EN 50131-8:2009 National foreword This British Standard is the UK implementation of EN 50131-8:2
2、009. It supersedes BS 7939:1999 which is withdrawn. The UK participation in its preparation was entrusted to Technical Committee GW/1, Electronic security systems. A list of organizations represented on this committee can be obtained on request to its secretary. This publication does not purport to
3、include all the necessary provisions of a contract. Users are responsible for its correct application. BSI 2009 ISBN 978 0 580 54903 8 ICS 13.320 Compliance with a British Standard cannot confer immunity from legal obligations. This British Standard was published under the authority of the Standards
4、 Policy and Strategy Committee on 31 July 2009 Amendments issued since publication Amd. No. Date Text affected BRITISH STANDARDBS EN 50131-8:2009 EUROPEAN STANDARD EN 50131-8 NORME EUROPENNE EUROPISCHE NORM May 2009 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Nor
5、malisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: avenue Marnix 17, B - 1000 Brussels 2009 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 50131-8:2009 E ICS 13.320 English version A
6、larm systems - Intrusion and hold-up systems - Part 8: Security fog device/systems Systmes dalarme - Systmes dalarme contre l intrusion et les hold-up - Partie 8: Systmes/dispositifs gnrateurs de fume Alarmanlagen - Einbruch- und berfallmeldeanlagen - Teil 8: Nebelgerte/Nebelsysteme fr Sicherungsanw
7、endungen This European Standard was approved by CENELEC on 2009-04-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliog
8、raphical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility
9、of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece,
10、Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS EN 50131-8:2009 EN 50131-8:2009 2 Foreword This European Standard was prepared by the Technical Commit
11、tee CENELEC TC 79, Alarm systems. The text of the draft was submitted to the formal vote and was approved by CENELEC as EN 50131-8 on 2009-04-01. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by
12、 endorsement (dop) 2010-04-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2012-04-01 The series EN/TS 50131 will consist of the following parts, under the general title “ Alarm systems Intrusion and hold-up systems” : Part 1 System requirements Part
13、 2-2 Intrusion detectors Passive infrared detectors Part 2-3 Requirements for microwave detectors Part 2-4 Requirements for combined passive infrared and microwave detectors Part 2-5 Requirements for combined passive infrared and ultrasonic detectors Part 2-6 Opening contacts (magnetic) Part 2-7-1 I
14、ntrusion detectors Glass break detectors (acoustic) Part 2-7-2 Intrusion detectors Glass break detectors (passive) Part 2-7-3 Intrusion detectors Glass break detectors (active) Part 3 Control and indicating equipment Part 4 Warning devices Part 5-3 Requirements for interconnections equipment using r
15、adio frequency techniques Part 6 Power supplies Part 7 Application guidelines Part 8 Security fog devices/systems _ BS EN 50131-8:2009 ? 3 EN 50131-8:2009 Contents Introduction.5 1Scope .6 2Normative references.6 3Definitions and abbreviations .6 3.1Definitions 6 3.2Abbreviations .7 4Environmental 7
16、 4.1 Environmental classification .7 4.2 Environmental tests .7 5Access levels 8 6Regulation requirements .8 6.1 General 8 6.2 Electrical safety 8 6.3 Safety data sheets .8 6.4 EMC requirements .8 6.5 Warning signs 8 6.6 Pressure vessels 8 7Device/system parameters 9 7.1 Performance .9 7.2 Battery b
17、ackup requirement .9 7.3 IP/IK rating .9 7.4 Wire free interconnections .9 8General requirements 9 8.1 Tamper .9 8.2 Fog neutralisation.9 8.3 Discharge nozzle10 8.4 Fog eject limiter 10 8.5 Heating unit 10 8.6 Overheating 10 8.7 Accidental triggering 10 8.8 Isolation of the security fog system 10 8.
18、9 Fixings 10 9Operational requirements .10 9.1 Communication 10 9.2 Fault monitoring .11 9.3 Power failure 11 9.4 Efficacy .11 9.5 Non-toxicity 12 9.6 Residue 12 BS EN 50131-8:2009 ? EN 50131-8:2009 4 10Consumables 12 10.1 Replenishment .12 10.2 Formulation 12 10.3 Traceability .12 11Marking 12 12Do
19、cumentation .12 13Design, installation, operation and maintenance (informative) 12 Annex A (normative) Performance tests 13 Annex B (normative) Security fog system warning sign 20 Annex C (informative) Guidance on design, installation, operation and maintenance of the security fog system 22 Bibliogr
20、aphy 24 Figures Figure A.1 Test chamber 17 Figure A.2 Target 18 Figure A.3 Partial target 19 Figure B.1 Security fog system warning sign . 20 Tables Table A.1 . 15 Table A.2 . 16 Table B.1 How to calculate the size of sign you need 21 BS EN 50131-8:2009 ? 5 EN 50131-8:2009 Introduction This European
21、 Standard applies to a security fog system that is part of an Intruder and Hold-up Alarm System (I b) Clause 10: cold test operational; c) Clause 14: damp heat, cyclic operational; d) Clause 17: sulphur dioxide (SO2) (endurance); e) Clause 20: impact operational; f) Clause 22: vibration sinusoidal (
22、operational); g) Clause 23: vibration sinusoidal (endurance); h) Clause 27: electromagnetic compatibility, immunity (operational). 5 Access levels The access levels used in this standard shall be as stated in EN 50131-1:2006, 8.3.1, except for access level 2. Access level 2 “ user” shall not be able
23、 to access the security fog system. 6 Regulation requirements 6.1 General The security fog system shall operate to the following minimum relevant European regulations. 6.2 Electrical safety The electrical (safety) construction of the security fog system shall be to EN 60065. 6.3 Safety data sheets T
24、he transport, storage and handling of consumables, shall comply with the requirements stated on the safety data sheets. 6.4 EMC requirements The security fog system shall meet the EMC conditions and the severity levels defined in EN 61000-6-3 and EN 50130-4. 6.5 Warning signs As a minimum security f
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS EN 50131-8-2009 Alarm systems Intrusion and hold-up Part Security fog devicesystems 50131 2009 hold
链接地址:https://www.31doc.com/p-3644438.html