BS EN 13126-8-2006 建筑五金.窗户和门上窗的要求和试验方法.倾斜和旋转、先倾斜和只旋转的五金.pdf
《BS EN 13126-8-2006 建筑五金.窗户和门上窗的要求和试验方法.倾斜和旋转、先倾斜和只旋转的五金.pdf》由会员分享,可在线阅读,更多相关《BS EN 13126-8-2006 建筑五金.窗户和门上窗的要求和试验方法.倾斜和旋转、先倾斜和只旋转的五金.pdf(26页珍藏版)》请在三一文库上搜索。
1、BRITISH STANDARD BS EN 13126-8:2006 Building hardware Requirements and test methods for windows and doors height windows Part 8: Tilt present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep UK interests informed; monitor rela
2、ted international and European developments and promulgate them in the UK. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 22, an inside back cover and a back cover. The BSI copyright notice displayed in this document indicates when the do
3、cument was last issued. Amendments issued since publication Amd. No. DateComments EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM February 2006 ICS 91.190Supersedes CEN/TS 13126-8:2004 English Version Building hardware - Requirements and test methods for windows and doors height windows - Part 8:
4、Tilt grade 5: 25 000. 4.4 Mass (3 third digit) The following grades shall be established in accordance with 4.4 of EN 13126-1:2006: 050, 060, 070, 080, 090, 100, 110, 120, 130, 140, 150, 160, 170, 180, 190 and 200 4.5 Fire resistance (4 fourth digit) One grade shall be identified in accordance with
5、4.5 of EN 13126-1:2006: grade 0 : no requirements. 4.6 Safety in use (5 fifth digit) One grade shall be identified in accordance with 4.6 of EN 13126-1:2006: grade 1: The hardware shall conform to the requirements of parts 1 and 8 from this standard. 4.7 Corrosion resistance (6 sixth digit) Hardware
6、 shall conform in accordance with 5.7 of this European Standard and 4.7 of EN 13126-1:2006 to the grades listed in EN 1670, whereby grade 3 is the minimum requirement. 4.8 Security (7 seventh digit) No marking is required for the category of security in accordance with 4.8 of EN 13126-1:2006. EN 131
7、26-8:2006 (E) 7 4.9 Applicable part (8 eighth digit) The eighth digit shows “8” indicating the part of the standard which was used for testing the Tilt 1 550 mm wide x 1 400 mm high (window mass 130 kg); 900 mm wide x 2 300 mm high (balcony door size). The stated sizes are test sizes only. They do n
8、ot relate to the maximum sizes to which a window may be fabricated. The manufacturer shall ensure, in accordance with the appropriate documentation, that for larger than recommended test-specimens the forces on the hardware do not exceed the test specimen forces. 4.11 Example of classification for T
9、ilt grade 5: 25 000 cycles (+ 1 %) (Turn-Only hardware). 5.4 Admissible tolerances 5.4.1 Sash operation tolerance The horizontal force in the vicinity of the sash support-component shall not exceed 120 N in order to close the sash from the turn-position. 5.4.2 Handle operation tolerance In conjuncti
10、on with a counteracting force of 20 1 0 N per locking point: maximum torque applied to the handle shall not exceed 10 Nm; maximum force applied to the handle shall not exceed 100 N. EN 13126-8:2006 (E) 12 5.4.3 Locking point variable tolerance Before and after the durability test, the distance “X” b
11、etween the frame surface and the sash-overlap-begin shall be measured in conjunction with a counteracting force of 20 1 0 N per locking point. The results shall not differ by more than 1 mm (see Figure 3). Key 1 frame 2 sash X measurement Figure 3 Measurement of locking point variable tolerance 5.5
12、Resistance to additional loading During and after the additional loading test, the sash shall remain on its hinges. NOTE It is not necessary for the sash to operate during and after the additional loading test. 5.6 Minimum closing device resistance The closing device shall withstand a minimum of 25
13、Nm. Upon completion of this exerted torque, the closing device shall operate. 5.7 Corrosion resistance Hardware shall conform to the grades listed in EN 1670, whereby grade 3 is the minimum requirement. For zinc galvanized surfaces on iron or steel the specified thickness of 12 m (class 3) or 16 m (
14、class 4) is not necessary if other surface protection methods are used to conform to the requirements (minimum time to formation of white corrosion products) of ISO 4520:1981 ( m = micrometre). Unless a test report can be provided by the manufacturer, the hardware shall be tested in accordance with
15、EN 1670. NOTE The evaluation of the corrosion resistance is limited to the essential areas (as a rule, the visible surfaces of the installed hardware). Exempt from the corrosion resistance evaluation are: - rivet locations; - locations of later processing (for example: cleaved surfaces that result f
16、rom cropping the hardware components, millings etc.); - non surface-treated parts/surfaces, provided they are not in the visible vicinity of the hardware (for example: screw guide-holes made of zinc die-cast etc.); - welding joints and their immediate surroundings. EN 13126-8:2006 (E) 13 5.8 Resista
17、nce to other additional tests After the additional reveal- and rebate-hindrance test the sash shall not drop. The hinges (scissor stay with stay bearing and corner pivot rest with sash hinge) shall still demonstrate a connection between the sash and the frame. NOTE It is not necessary for the sash t
18、o operate. 6 Test equipment The Tilt sample B corrosion tests (hardware set); sample C retained for reference control (hardware set). NOTE 1 Sample B should only be necessary if no test report can be supplied from the manufacturer regarding the testing of the hardware component or set in accordance
19、with EN 1670. NOTE 2 Sample C should be retained by the test institute for the duration of the validity of the test report. 7.2 Stability of hinge The results of the tests shall be submitted by the hardware manufacturer by a self declaration with supporting documentation to the test house in accorda
20、nce with 5.2.2. 7.3 Durability test Tilt 15 000 times Lock; 15 000 times Turn (100 mm); 15 000 times Lock. For both Tilt sash movement into the tilt position (or turn position 100 mm); sash movement back to the closed position, hardware to be locked; sash movement into the turn position 100 mm (or t
21、ilt position); sash movement back into the closed position, hardware to be locked. The durability tests shall be performed at a rate of 250 25 0 cycles/h in accordance with 8.2 of EN 13126-1:2006, except in the case of a manufacturer choosing the option of specifying a lower testing speed, e.g. to a
22、void any friction-material overheating. In this case the test report shall specify the testing- speed and the reasons for using the lower speed. During the durability test, the test specimen shall be operated by use of a window-handle. The connection of the manipulator-rig (see Figure A.1 Annex A) t
23、o the window-handle is to be set up in such a way, that only torque during closing, and tractive force during opening occur, which correspond to the strain in practice. 7.3.2.2 Tilt position The sash is moved into the scissors-stay final-position (stopped by the stay arm/s allowing normal vibration
24、to occur) through the test rig with a velocity of 0,50 m/s ( 10 %), which shall be 5 mm before reaching the final tilted position. A spring-revert of the sash in the tilted position shall be possible e.g. before the test sash reaches its maximum tilt position the pneumatic cylinder is released (valv