BS EN 15267-1-2009 Air quality — Certification of automated measuring systems Part 1 General principles.pdf
《BS EN 15267-1-2009 Air quality — Certification of automated measuring systems Part 1 General principles.pdf》由会员分享,可在线阅读,更多相关《BS EN 15267-1-2009 Air quality — Certification of automated measuring systems Part 1 General principles.pdf(20页珍藏版)》请在三一文库上搜索。
1、? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? BS EN 15267-1:2009BS EN 15267-1:2009 EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 15267-1 March 2009 ICS 13.040.99 English Version Air quality - Certification of automated measuring systems - Part 1: General principles Qualit de l
2、air - Certification des systmes de mesurage automatiss - Partie 1 : Principes gnraux Luftbeschaffenheit - Zertifizierung von automatischen Messeinrichtungen - Teil 1: Grundlagen This European Standard was approved by CEN on 14 February 2009. CEN members are bound to comply with the CEN/CENELEC Inter
3、nal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN Management Centre or to any CEN memb
4、er. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the official versions. CEN membe
5、rs are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, S
6、witzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2009 CENAll rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. N
7、o. EN 15267-1:2009: E BS EN 15267-1:2009BS EN 15267-1:2009 EN 15267-1:2009 (E) 2 Contents Page Foreword 3 Introduction .4 1Scope 5 2Normative references 5 3Terms and definitions .6 4Abbreviations .7 5Principles 7 5.1Performance testing of the automated measuring system .7 5.2Initial assessment of th
8、e AMS manufacturers quality management system .8 5.3Certification 8 5.4Surveillance 8 6Roles and responsibilities 9 6.1General 9 6.2Roles and responsibilities of the manufacturer .9 6.3Roles and responsibilities of the test laboratory .9 6.4Roles and responsibilities of the relevant body 10 7Certifi
9、cation procedure 11 7.1General . 11 7.2Performance testing of the automated measuring system 11 7.3Initial assessment of the manufacturers quality management system . 11 7.4Certification . 11 7.5Surveillance . 12 7.6Review of certifications 13 Annex A (informative) Application and assessment process
10、es 14 Annex B (informative) Example certificate template . 15 Bibliography . 17 ? BS EN 15267-1:2009BS EN 15267-1:2009 EN 15267-1:2009 (E) 3 Foreword This document (EN 15267-1:2009) has been prepared by Technical Committee CEN/TC 264 “Air quality”, the secretariat of which is held by DIN. This Europ
11、ean Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by September 2009, and conflicting national standards shall be withdrawn at the latest by September 2009. Attention is drawn to the possibility that some of the
12、elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document is Part 1 of a series of European Standards: EN 15267-1, Air quality Certification of automated measuring systems Part 1: Gener
13、al principles EN 15267-2, Air quality Certification of automated measuring systems Part 2: Initial assessment of the AMS manufacturers quality management system and post certification surveillance for the manufacturing process EN 15267-3, Air quality Certification of automated measuring systems Part
14、 3: Performance criteria and test procedures for automated measuring systems for monitoring emissions from stationary sources According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Bel
15、gium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. ? BS EN 15267-1:2
16、009BS EN 15267-1:2009 EN 15267-1:2009 (E) 4 Introduction The certification of automated measuring systems (AMS) supports the requirements of certain Directives of the European Union (EU), which require, either directly or indirectly, that AMS comply with performance criteria, maximum permissible mea
17、surement uncertainties and testing requirements. These Directives include the Directive on the limitation of emissions of certain pollutants into the air from large combustion plants 1, the Directive on the incineration of waste 2 and the Framework Directive on ambient air quality assessment and man
18、agement 3 and the associated daughter directives 4, 5, 6 and 7. The responsibility for approving AMS for monitoring ambient air quality under Directive 96/62/EC lies with the national competent authority or a body designated by the EU member state. No explicit requirement for approving AMS for monit
19、oring emissions from stationary sources is defined in the relevant EU Directives, although the competent authorities in some EU member states have such arrangements in place. In some EU member states the competent authority delegates the responsibility for approval of AMS to a certification body acc
20、redited to EN 45011 by national accreditation bodies. In some EU member states the competent authority cannot be accredited by external bodies, in others they may be. These approaches have built up over many years and reflect the different administrative and legal arrangements that exist in the EU m
21、ember states. In order to recognize these different approaches, this European Standard uses the collective term “relevant body” when referring to competent authority or certification body. The terms “competent authority” and “certification body” are only used where it is necessary to be specific for
22、 the purpose of clarity in the way in which a requirement applies under the different approaches. The European Standard EN 45011 specifies general criteria that a certification body operating product certification shall follow if it is to be recognized at a national or European level as competent an
23、d reliable in the operation of a product certification system, irrespective of the sector involved. It is intended for the use of accreditation bodies concerned with recognizing the competence of certification bodies. EN 45011 is identical to ISO/IEC Guide 65. The document EA-6/01 8 published by the
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS EN 15267-1-2009 Air quality Certification of automated measuring systems Part General principles 15267
链接地址:https://www.31doc.com/p-3646507.html