BS EN 54-16-2008 火灾探测和火灾警报系统.声音报警控制和指示设备.pdf
《BS EN 54-16-2008 火灾探测和火灾警报系统.声音报警控制和指示设备.pdf》由会员分享,可在线阅读,更多相关《BS EN 54-16-2008 火灾探测和火灾警报系统.声音报警控制和指示设备.pdf(68页珍藏版)》请在三一文库上搜索。
1、BRITISH STANDARD BS EN 54-16:2008 Fire detection and fire alarm systems Part 16: Voice alarm control and indicating equipment ICS 13.220.20 BS EN 54-16:2008 This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 March 2008 BSI 2008 ISBN 978 0 580
2、 54278 7 National foreword This British Standard is the UK implementation of EN 54-16:2008. The UK participation in its preparation was entrusted by Technical Committee FSH/12, Fire detection and alarm systems, to Subcommittee FSH/12/5, Alarm devices, voice alarm evacuation sub-systems and emergency
3、 voice communications. A list of organizations represented on this committee can be obtained on request to its secretary. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard can
4、not confer immunity from legal obligations. Amendments/corrigenda issued since publication DateComments W - - - -8- 7 W7 -8 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - W W D - - w - - - - EN 54-16:2008 (E) 2 Contents Page Foreword4 Introduction.6 1 Scope 7 2 Normative reference
5、s7 3 Terms, definitions and abbreviations8 3.1 Terms and definitions .8 3.2 Abbreviations.10 4 General requirements11 4.1 General11 4.2 Combined VACIE and CIE.11 4.3 Power supply11 5 General requirements for indications11 5.1 Display and functional conditions.11 5.2 Indication display.12 5.3 Indicat
6、ion on alphanumeric displays.12 5.4 Indication of the supply of power 12 5.5 Additional indications .12 6 The quiescent condition .12 7 The voice alarm condition 12 7.1 Reception and processing of fire signals .12 7.2 Indication of the voice alarm condition.13 7.3 Audible warning (option with requir
7、ements) 13 7.4 Delays to entering the voice alarm condition (option with requirements) 13 7.5 Phased evacuation (option with requirements)13 7.6 Silencing of the voice alarm condition13 7.7 Reset of the voice alarm condition14 7.8 Output to fire alarm devices (option with requirements) 14 7.9 Voice
8、alarm condition output (option with requirements) 14 8 Fault warning condition 14 8.1 Reception and processing of fault signals .14 8.2 Indication of faults in specified functions.15 8.3 Indication of faults related to the transmission path to the CIE (option with requirements) 16 8.4 Indication of
9、faults related to voice alarm zones (option with requirements).16 8.5 System fault16 8.6 Audible indication16 8.7 Reset of fault indications16 8.8 Transmission of the fault warning condition16 9 Disablement condition (option with requirements)17 9.1 General requirements17 9.2 Indication of the disab
10、led condition17 9.3 Indication of specific disablements.17 9.4 Disablements and their indication.17 9.5 Transmission of the disablement condition .17 10 Voice alarm manual control (option with requirements).18 10.1 General requirements18 10.2 Indication of the voice alarm zones in an activated condi
11、tion .18 10.3 Indication of the voice alarm zones in fault condition.18 BS EN 54-16:2008 EN 54-16:2008 (E) 3 10.4 Indication of the voice alarm zones in disablement condition.18 11 Interface to external control device(s) (option with the requirements) .18 12 Emergency microphone(s) (option with requ
12、irements) 19 13 Design requirements.19 13.1 General requirements and manufacturers declaration 19 13.2 Documentation 20 13.3 Mechanical design requirements.20 13.4 Electrical and other design requirements.21 13.5 Integrity of transmission paths21 13.6 Accessibility of indications and controls .21 13
13、.7 Indications by means of light emitting indicators .22 13.8 Indications on alphanumeric displays22 13.9 Indication colours22 13.10 Audible indications .23 13.11 Indicator testing.23 13.12 Audio performance23 13.13 Message store(s) .25 13.14 Redundant power amplifiers (option with requirements) .25
14、 14 Additional design requirements for software controlled VACIE25 14.1 General requirements and manufacturers declarations 25 14.2 Software documentation.25 14.3 Software design.26 14.4 Program monitoring (see also Annex C).26 14.5 The storage of programs and data (see also Annex C).27 14.6 Monitor
15、ing of memory contents 27 15 Marking.27 16 Tests .28 16.1 General .28 16.2 Functional tests.29 16.3 Audio performance and environmental tests.31 16.4 Output power.32 16.5 Signal-to-noise ratio34 16.6 Frequency response of VACIE without microphone(s).35 16.7 Frequency response of VACIE with microphon
16、e(s) 36 16.8 Cold (operational)37 16.9 Damp heat, steady state (operational) 38 16.10 Damp heat, steady state (endurance)39 16.11 Impact (operational)40 16.12 Vibration, sinusoidal (operational)41 16.13 Vibration, sinusoidal (endurance) .42 16.14 Supply voltage variation (operational)42 16.15 Electr
17、omagnetic Compatibility (EMC), Immunity tests (operational).43 Annex A (informative) Explanation of access level.45 Annex B (informative) Optional functions with requirements and alternatives.47 Annex C (informative) Design requirements for software controlled VACIE49 Annex D (informative) General i
18、nformation about voice alarm systems 50 Annex E (informative) Interface between the VACIE and the CIE53 Annex F (informative) Common indications, controls and outputs when the VACIE and the CIE are combined .54 Annex ZA (informative) Clauses of this European Standard addressing the provisions of the
19、 EU Construction Products Directive (89/106/EEC) 56 Bibliography65 BS EN 54-16:2008 EN 54-16:2008 (E) 4 Foreword This document (EN 54-16:2008) has been prepared by Technical Committee CEN/TC 72 “Fire detection and fire alarm systems”, the secretariat of which is held by BSI. This European Standard s
20、hall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by September 2008, and conflicting national standards shall be withdrawn at the latest by March 2011. Attention is drawn to the possibility that some of the elements of this d
21、ocument may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential require
22、ments of EU Directive(s). For relationship with EU Directive, see informative Annex ZA, which is an integral part of this document. EN 54 Fire detection and fire alarm systems consists of the following parts: Part 1: Introduction Part 2: Control and indicating equipment Part 3: Fire alarm devices So
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS EN 54-16-2008 火灾探测和火灾警报系统.声音报警控制和指示设备 54 16 2008 火灾 探测 警报 系统 声音 报警 控制 指示 设备
链接地址:https://www.31doc.com/p-3647125.html