BS EN 61049-1993 管形荧光灯和其它放电灯电路用电容器性能要求规范.pdf
《BS EN 61049-1993 管形荧光灯和其它放电灯电路用电容器性能要求规范.pdf》由会员分享,可在线阅读,更多相关《BS EN 61049-1993 管形荧光灯和其它放电灯电路用电容器性能要求规范.pdf(16页珍藏版)》请在三一文库上搜索。
1、BRITISH STANDARD BS EN 61049:1993 Specification for Capacitors for use in tubular fluorescent and other discharge lamp circuits Performance requirements The European Standard EN 61049:1993 has the status of a British Standard UDC 621.327.534.15.032 BS EN 61049:1993 This British Standard, having been
2、 prepared under the direction of the Electrical Illuminations Standards Policy Committee, was published under the authority of the Standards Board and comes into effect on 15 September 1993 BSI 04-1999 The following BSI references relate to the work on this standard: Committee reference LGL/21 Draft
3、 for comment 8928666 DC ISBN 0 580 22483 X Cooperating organizations The European Committee for Electrotechnical Standardization (CENELEC), under whose supervision this European Standard was prepared, comprises the national committees of the following countries: AustriaItaly BelgiumLuxembourg Denmar
4、kNetherlands FinlandNorway FrancePortugal GermanySpain GreeceSweden IcelandSwitzerland IrelandUnited Kingdom Amendments issued since publication Amd. No.DateComments BS EN 61049:1993 BSI 04-1999i Contents Page Cooperating organizationsInside front cover National forewordii Foreword2 Text of EN 61049
5、3 National annex NA (informative) Original IEC text amended by CENELEC common modifications9 National annex NB (informative) Committees responsible10 National annex NC (informative) Cross-references10 BS EN 61049:1993 ii BSI 04-1999 National foreword This British Standard has been prepared under the
6、 direction of the Electrical Illuminations Standards Policy Committee and is the English language version of EN 61049:1993 Capacitors for use in tubular fluorescent and other discharge lamp circuits. Performance requirements, published by the European Committee for Electrotechnical Standardization (
7、CENELEC). It was derived by CENELEC from IEC 1049:1991, together with its Corrigendum:1992, published by the International Electrotechnical Commission (IEC). The CENELEC common modifications have been implemented at the appropriate places in the text and are indicated by a side line in the margin. P
8、arts of the original IEC text which do not form part of the text of EN 61049 have been quoted in National annex NA. Textual error. The common modification in clause 4, which refers to clause 16, should read “clause 16 of IEC 1048”. This British Standard, together with BS EN 61048, supersedes BS 4017
9、:1979 which is withdrawn. The following print types are used in this standard: requirement proper: in roman type; test specification: in italic type; notes: in smaller roman type. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards ar
10、e responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, the EN title page, pages 2 to 10 and a back cover. This standard h
11、as been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover. EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 61049 May 1993 UDC 621.327.534.15.032 Descriptors: Discharge lamp, tubular lamp, fluorescent la
12、mp, capacitor, characteristic, electrical capacitance, test, specification English version Capacitors for use in tubular fluorescent and other discharge lamp circuits Performance requirements (IEC 1049:1991 + corrigendum 1992, modified) Condensateurs destins tre utiliss dans les circuits de lampes t
13、ubulaires fluorescence et autres lampes dcharge Prescriptions de performances (CEI 1049:1991 + corrigendum 1992, modifie) Kondensatoren fr Entladungslampen, insbesondere Leuchtstofflampen-Anlagen Leistungsanforderungen (IEC 1049:1991 + corrigendum 1992, modifiziert) This European Standard was approv
14、ed by CENELEC on 1992-12-09. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nation
15、al standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language
16、and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switze
17、rland and United Kingdom. CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B-1050 Brussels 1993 Copyright reserved to CENELEC members Ref. No. EN 6
18、1049:1993 E EN 61049:1993 BSI 04-1999 2 Foreword At the request of CENELEC Technical Committee TC 34Z, Luminaires and associated equipment, the text of the International Standard IEC 1049:1991 and its corrigendum of January 1992, together with the common modifications prepared by TC 34Z, was submitt
19、ed to the CENELEC members for formal vote in July 1992 for acceptance as a European Standard. The text of the draft was approved by CENELEC as EN 61049 on 9 December 1992. The following dates were fixed: For products which have complied with the relevant national standard before 1993-12-01, as shown
20、 by the manufacturer or by a certification body, this previous standard may continue to apply for production until 1998-12-01. Annexes designated “normative” are part of the body of the standard. In this standard, Annex A, Annex B and Annex ZA are normative. Contents Page Foreword2 1General3 1.1Scop
21、e3 1.2Normative references3 2Definitions3 3General notes on tests3 4Testing sequence4 5Marking4 6Capacitance4 7Change of capacitance with temperature5 8Endurance test5 Annex A (normative) Conformity of production8 Annex B (normative) Test voltage8 Annex ZA (normative) Other international publication
22、s quoted in this standard with the references of the relevant European publications8 latest date of publication of an identical national standard(dop) 1993-12-01 latest date of withdrawal of conflicting national standards(dow) 1993-12-01 EN 61049:1993 BSI 04-19993 1 General 1.1 Scope This Internatio
23、nal Standard states the requirements for both self-healing and non-self-healing continuously rated a.c. capacitors of up to and including 2,5 kvar, and not less than 0,1 F, having a rated voltage not exceeding 1 000 V, which are intended for use in discharge lamp circuits1) operating at 50 Hz or 60
24、Hz and at altitudes up to 3 000 m. It covers capacitors intended for connection in shunt or in series with the lamp circuit or an effective combination of these. It covers only impregnated or unimpregnated capacitors, having a dielectric of paper, plastic film or a combination of both, either metall
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS EN 61049-1993 管形荧光灯和其它放电灯电路用电容器性能要求规范 61049 1993 荧光灯 其它 电灯 电路 用电 容器 性能 要求 规范
链接地址:https://www.31doc.com/p-3647862.html