IEEE std 1018-1991 recommended practice for specifying electric submersible pump cable-ethylene-propylene rubber insulation.pdf
《IEEE std 1018-1991 recommended practice for specifying electric submersible pump cable-ethylene-propylene rubber insulation.pdf》由会员分享,可在线阅读,更多相关《IEEE std 1018-1991 recommended practice for specifying electric submersible pump cable-ethylene-propylene rubber insulation.pdf(30页珍藏版)》请在三一文库上搜索。
1、Recognized as an American National Standard (ANSI) IEEE Std 1018-1991 (Revision of IEEE Std 1018-1985) IEEE Recommended Practice for Specifying Electric Submersible Pump Cable-Ethylene-Propylene Rubber Insulation IEEE Industry Applications Society ? 2 Sponsored by the 4 a Petroleum and Chemical Indu
2、stry Committee h Published by the Institute of Electrical and Electronics Engineers, Inc., 345 East 47th Street, New York, NY lWlZ USA. lEEE August 14, 1992 SH15016 THIS PAGE WAS BLANK IN THE ORIGINAL Recognized as an American National Standard (ANSI) IEEE Std 1018-1991 (Revision of EEE Std 1018-198
3、5) IEEE Recommended Practice for Specifying Electric Submersible Pump Cable- Ethylene-Propylene Rubber Insulation Sponsor Petroleum and Chemical Industry Committee of the IEEE Industry Applications Society Approved December 5,1991 IEEE Standards Board Approved May 14,1992 American National Standards
4、 Institute Abstract: Minimum requirements for the construction, manufacturing, purchasing, and application of electric submersible pump (ESP) cable are presented. The cable is round or flat, with ethylene-propylene rubber insulation, nitrile jacket, and armor, and is rated for voltages not exceeding
5、 3 kV or 5 kV and for ambient temperatures not exceeding 284 OF. Conductors, insulation, barrier (optional), assembly and jacket, armor, requirements for testing by the manufacturer, and cable ampacity are covered. Keywords: test equipment, dc hi-pot test methods, test voltages. The Institute of Ele
6、ctrical and Electronics Engineers, Inc. 345 East 47th Street, New York, NY 10017-2394, USA Copyright Q 1992 by the Institute of Electrical and Electronics Engineers, Inc. All rights reserved. Published 1992 Printed in the United States ofAmerica ISBN 1-55937-193-5 No part of this publication may be
7、reproduced in any form, in an electronic retrieval system or otherwise, without the prior written permission of the publisher. lEEE Standards documents are developed within the Technical Com- mittees of the IEEE Societies and the Standards Coordinating Commit- tees of the IEEE Standards Board. Membe
8、rs of the committees serve voluntarily and without compensation. They are not necessarily members of the Institute. The standards developed within IEEE represent a con- sensus of the broad expertise on the subject within the Institute as well as those activities outside of IEEE that have expressed a
9、n interest in partic- ipating in the development of the standard. Use of an IEEE Standard is wholly voluntary. The existence of an IEEE Standard does not imply that there are no other ways to produce, test, measure, purchase, market, or provide other goods and services related to the scope of the IE
10、EE Standard. Furthermore, the viewpoint expressed at the time a standard is approved and issued is subject to change brought about through developments in the state of the art and comments received from users of the standard. Every IEEE Standard is subjected to review at least every five years for r
11、evision or reaffirmation. When a docu- ment is more than five years old and has not been reaffirmed, it is reason- able to conclude that its contents, although still of some value, do not wholly reflect the present state of the art. Users are cautioned to check to determine that they have the latest
12、 edition of any IEEE Standard. Comments for revision of IEEE Standards are welcome from any inter- ested party, regardless of membership affiliation with IEEE. Suggestions for changes in documents should be in the form of a proposed change of text, together with appropriate supporting comments. Inte
13、rpretations: Occasionally questions may arise regarding the mean- ing of portions of standards as they relate to specific applications. When the need for interpretations is brought to the attention of IEEE, the Insti- tute will initiate action to prepare appropriate responses. Since IEEE Standards r
14、epresent a consensus of all concerned interests, it is impor- tant to ensure that any interpretation has also received the concurrence of a balance of interests. For this reason IEEE and the members of its technical committees are not able to provide an instant response to inter- pretation requests
15、except in those cases where the matter has previously received formal consideration. Comments on standards and requests for interpretations should be addressed to: Secretary, IEEE Standards Board 445 Hoes Lane P.O. Box 1331 Piscataway, NJ 08855-1331 USA IEEE Standards documents are adopted by the In
16、stitute of Electrical and Electronics Engineers without regard to whether their adoption may involve patents on articles, materials, or processes. Such adoption does not assume any liability to any patent owner, nor does it assume any obligation whatever to parties adopting the standards documents.
17、Foreword (This foreword is not a part of IEEE Std 1018-1991, IEEE Recommended Practice for Specifying Electric Submers- ible Pump C a b l e Ethylene-Propylene Rubber Insulation.) This recommended practice, under the jurisdiction of the Petroleum and Chemical Industry Committee of the IEEE Industry A
18、pplications Society, presents minimum requirements for the construction, manufacturing, purchasing, and application of electric submersible pump cable. The configuration of the cable is either round or flat, with ethylene-propylene rubber insula- tion, nitrile jacket, and armor. Anyone desiring to u
19、se this recommended practice may do so. It is presented as minimum criteria for construction of this class of submersible cable. It is not intended to restrict innova- tion or to limit development of improvements in cable design. Every effort has been made to assure the accuracy and reliability of t
20、he data contained herein; however, the committee makes no representation, warranty, or guarantee in connection with the publication of this specification and hereby expressly disclaims any liability or responsibility for loss or damage resulting from its use, for any violation of any federal, state,
21、 or municipal regulation with which it may conflict, or for the infringement of any patent resulting from the use of this doc- ument. At the time that this standard was completed, the Downhole Working Group of the Petroleum and Chemical Industry Committee had the following membership: M. 0. Durham,
22、Chair S. C. Roberts, Secretary Gordon Baker Eelko Bergsma Ray Guzy Clark Lockerd Burt MacKenzie Mike Wedel At the time this standard was balloted and approved for submission to the IEEE Standards Board, the Petroleum and Chemical Industry Committee of the IEEE Industry Applications Society had the f
23、ollowing membership: Russell E. Adams J. K. Armintor S. P. Axe David C. Azbill Iraj Boroumand R. Bried D. G. Broussard M. M. Cameron W. F. Casper James M. Daly Stephen M. Dillard Gary Donner Richard Doughty Joseph S. Dudor Marcus 0. Durham J. B. Dwyer H. B. Dygert C. J. Erickson E. J. Fagan R. W. Ga
24、llant S. W. Hagemoen J. D. Hill F. P. Hogan Richard H. Hulett John Hus Robert M. Jackson M. Johnson Ben Johnson John H. Kassebaum P. M. Kinney J. C. Lacour W. H. Levers Clark R. Lockerd B. W. McCarty Bob McDaniel Paul W. Myers R. L. Nailen R. A. Neil J. P. Nelson J. B. Overmeyer T. P. Pearson B, M.
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- IEEE std 1018-1991 recommended practice for specifying electric submersible pump cable-ethylene-propylene 1018
链接地址:https://www.31doc.com/p-3658230.html