NEMA MS 9-2008 Characterization of Phased Array Coils for Diagnostic Magnetic Resonance Images.pdf
《NEMA MS 9-2008 Characterization of Phased Array Coils for Diagnostic Magnetic Resonance Images.pdf》由会员分享,可在线阅读,更多相关《NEMA MS 9-2008 Characterization of Phased Array Coils for Diagnostic Magnetic Resonance Images.pdf(17页珍藏版)》请在三一文库上搜索。
1、 NEMA Standards Publication MS 9-2008 Characterization of Phased Array Coils for Diagnostic Magnetic Resonance Images Published by National Electrical Manufacturers Association 1300 North 17th Street, Suite 1752 Rosslyn, Virginia 22209 www.nema.org Copyright 2008 by the National Electrical Manufactu
2、rers Association. All rights including translation into other languages, reserved under the Universal Copyright Convention, the Berne Convention for the Protection of Literary and Artistic Works, and the International and Pan American Copyright Conventions. NOTICE AND DISCLAIMER The information in t
3、his publication was considered technically sound by the consensus of persons engaged in the development and approval of the document at the time it was developed. Consensus does not necessarily mean that there is unanimous agreement among every person participating in the development of this documen
4、t. The National Electrical Manufacturers Association (NEMA) standards and guideline publications, of which the document contained herein is one, are developed through a voluntary consensus standards development process. This process brings together volunteers and/or seeks out the views of persons wh
5、o have an interest in the topic covered by this publication. While NEMA administers the process and establishes rules to promote fairness in the development of consensus, it does not write the document and it does not independently test, evaluate, or verify the accuracy or completeness of any inform
6、ation or the soundness of any judgments contained in its standards and guideline publications. NEMA disclaims liability for any personal injury, property, or other damages of any nature whatsoever, whether special, indirect, consequential, or compensatory, directly or indirectly resulting from the p
7、ublication, use of, application, or reliance on this document. NEMA disclaims and makes no guaranty or warranty, expressed or implied, as to the accuracy or completeness of any information published herein, and disclaims and makes no warranty that the information in this document will fulfill any of
8、 your particular purposes or needs. NEMA does not undertake to guarantee the performance of any individual manufacturer or sellers products or services by virtue of this standard or guide. In publishing and making this document available, NEMA is not undertaking to render professional or other servi
9、ces for or on behalf of any person or entity, nor is NEMA undertaking to perform any duty owed by any person or entity to someone else. Anyone using this document should rely on his or her own independent judgment or, as appropriate, seek the advice of a competent professional in determining the exe
10、rcise of reasonable care in any given circumstances. Information and other standards on the topic covered by this publication may be available from other sources, which the user may wish to consult for additional views or information not covered by this publication. NEMA has no power, nor does it un
11、dertake to police or enforce compliance with the contents of this document. NEMA does not certify, test, or inspect products, designs, or installations for safety or health purposes. Any certification or other statement of compliance with any health or safety- related information in this document sh
12、all not be attributable to NEMA and is solely the responsibility of the certifier or maker of the statement. MS 9-2008 Page i Copyright 2008 by the National Electrical Manufacturers Association. CONTENTS Page Preamble .iii Forewordiv Rationale v Scope vi Section 1 DEFINITIONS1 1.1 Coil-Related Defin
13、itions.1 1.1.1 Sensitive Volume1 1.1.2 Sensitive Area 1 1.1.3 Imaging Region of Interest (IROI) 1 1.1.4 Reference Position.1 1.1.5 Phased Array Coils.1 1.1.6 Sub-Coils1 1.1.7 Sub-Coil Sets (or Modes).1 1.1.8 Phased Array Surface Sub-Coils.1 1.1.9 Phased Array Volume Sub-Coils.1 1.2 Analysis-Related
14、Definitions2 1.2.1 Characterization Volume2 1.2.2 Characterization Area.2 1.2.3 Measurement Region of Interest (MROI).2 1.2.4 Measurement Subregion of Interest (SROI).2 1.2.5 Specification Volume2 1.3 Phantom-Related Definitions.2 1.3.1 Signal-Producing Volume (Phantom).2 1.4 Image-Related Definitio
15、ns.2 1.4.1 Image Artifact .2 1.4.2 Image Uniformity/Nonuniformity.2 1.4.3 Baseline Pixel Offset Value3 1.4.4 Image Signal.3 1.4.5 Image Noise .3 1.4.6 Image Signal-to-Noise Ratio 3 Section 2 METHODS OF MEASUREMENT .4 2.1 Test Hardware.4 2.1.1 MR Characteristics of the Signal Producing Volume (Phanto
16、m)4 2.1.2 RF Coil Loading Characteristics.4 2.1.3 RF Coil and Positioning Device4 2.2 Selection of Measurement Geometry4 2.2.1 Selection of the Reference Position , Characterization Volume and Area.4 2.2.2 Measurement Region-of-Interest (MROI).5 2.2.3 Noise Evaluation Area5 2.2.4 Slice Positions 5 2
17、.3 Scan Conditions 5 2.4 Measurement Procedure.5 Section 3 REPORTING OF RESULTS .7 3.1 Reporting of SNR 7 3.1.1 Geometric Information7 3.1.2 Data-Acquisition Parameters7 3.1.3 SNR Results.8 MS 9-2008 Page ii Copyright 2008 by the National Electrical Manufacturers Association. 3.2 Reporting of Unifor
18、mity8 3.2.1 Geometric and Phantom Information .8 3.2.2 Data-Acquisition Parameters8 3.2.3 Uniformity Results 8 3.3 Uncertainty of Measurements8 Annex A Changes to Standard.9 MS 9-2008 Page iii Copyright 2008 by the National Electrical Manufacturers Association. Preamble This is one of a series of te
19、st standards developed by the medical diagnostic imaging industry for the measurement of performance parameters governing image quality of magnetic resonance (MR) imaging (MRI) systems. These test standards are intended for the use of equipment manufacturers, prospective purchasers, and users alike.
20、 Manufacturers are permitted to use these standards for the determination of system performance specifications. This standardization of performance specifications is of benefit to the prospective equipment purchaser, and the parameters supplied with each NEMA measurement serve as a guide to those fa
21、ctors that can influence the measurement. These standards can also serve as reference procedures for acceptance testing and periodic quality assurance. It must be recognized, however, that not all test standards lend themselves to measurement at the installation site. Some test standards require ins
22、trumentation better suited to factory measurements, while others require the facilities of an instrumentation laboratory to assure stable test conditions necessary for reliable measurements. The NEMA test procedures are carried out using the normal clinical operating mode of the system. For example,
23、 standard calibration procedures, standard clinical sequences, and standard reconstruction processes shall be used. No modifications to alter test results shall be used unless otherwise specified in these standards. The NEMA Magnetic Resonance Section has identified a set of key magnetic resonance i
24、mage quality parameters. This standards publication describes the measurement of two of these parameters (SNR and Uniformity) for phased array coils. Equivalence It is intended and expected that manufacturers or others who claim compliance with these NEMA standard test procedures for the determinati