NEMA PB 2.2-1999(R2004, R2009) Application Guide for Ground Fault Protective (GFP) Devices for Equipment1.pdf
《NEMA PB 2.2-1999(R2004, R2009) Application Guide for Ground Fault Protective (GFP) Devices for Equipment1.pdf》由会员分享,可在线阅读,更多相关《NEMA PB 2.2-1999(R2004, R2009) Application Guide for Ground Fault Protective (GFP) Devices for Equipment1.pdf(41页珍藏版)》请在三一文库上搜索。
1、 N NE EMMA A PB B 2. .2 2 APPLICATION GUIDE FOR GROUND FAULT PROTECTIVE DEVICES FOR EQUIPMENT NEMA Standards Publication PB 2.2-1999 (R2004, R2009) Application Guide for Ground Fault Protective Devices for Equipment Published by National Electrical Manufacturers Association 1300 N 17th Street, Suite
2、 1752 Rosslyn, VA 22209 www.nema.org ! Copyright 2009 by the National Electrical Manufacturers Association. All rights including translation into other languages, reserved under the Universal Copyright Convention, the Berne Convention for the Protection of Literacy and Artistic Works, and the Intern
3、ational and Pan American Copyright Conventions. ? NOTICE AND DISCLAIMER The information in this publication was considered technically sound by the consensus of persons engaged in the development and approval of the document at the time it was developed. Consensus does not necessarily mean that ther
4、e is unanimous agreement among every person participating in the development of this document. The National Electrical Manufacturers Association (NEMA) standards and guideline publications, of which the document contained herein is one, are developed through a voluntary consensus standards developme
5、nt process. This process brings together volunteers and/or seeks out the views of persons who have an interest in the topic covered by this publication. While NEMA administers the process and establishes rules to promote fairness in the development of consensus, it does not write the document and it
6、 does not independently test, evaluate, or verify the accuracy or completeness of any information or the soundness of any judgments contained in its standards and guideline publications. NEMA disclaims liability for any personal injury, property, or other damages of any nature whatsoever, whether sp
7、ecial, indirect, consequential, or compensatory, directly or indirectly resulting from the publication, use of, application, or reliance on this document. NEMA disclaims and makes no guaranty or warranty, expressed or implied, as to the accuracy or completeness of any information published herein, a
8、nd disclaims and makes no warranty that the information in this document will fulfill any of your particular purposes or needs. NEMA does not undertake to guarantee the performance of any individual manufacturer or sellers products or services by virtue of this standard or guide. In publishing and m
9、aking this document available, NEMA is not undertaking to render professional or other services for or on behalf of any person or entity, nor is NEMA undertaking to perform any duty owed by any person or entity to someone else. Anyone using this document should rely on his or her own independent jud
10、gment or, as appropriate, seek the advice of a competent professional in determining the exercise of reasonable care in any given circumstances. Information and other standards on the topic covered by this publication may be available from other sources, which the user may wish to consult for additi
11、onal views or information not covered by this publication. NEMA has no power, nor does it undertake to police or enforce compliance with the contents of this document. NEMA does not certify, test, or inspect products, designs, or installations for safety or health purposes. Any certification or othe
12、r statement of compliance with any health or safety related information in this document shall not be attributable to NEMA and is solely the responsibility of the certifier or maker of the statement. ? PB 2.2-1999 (R2004, R2009) Page i TABLE OF CONTENTS Section 1 GENERAL .1 1.1 Scope1 1.2 Referenced
13、 Standards1 1.2.1Other references .2 Section 2 INTRODUCTION.4 2.1 Arcing Ground Faults4 2.2 Need for Ground Fault Protection.4 2.3 Standards4 2.4 ApplicationGeneral4 2.5 Relay Setting SelectionsGeneral 5 2.6 Methods of GFP Device Selectivity.5 2.7 Damage Levels.5 Section 3 POWER CIRCUIT.6 3.1 Voltag
14、e6 3.2 Frequency.6 3.3 Current Rating.6 3.4 Location of Ground Fault Sensing Devices 6 3.4.1Ground Return Method .6 3.4.2Outgoing Circuit Method (Residual or Zero-Sequence)6 3.5 Ground Connections.6 3.6 Mounting and Connection Of Ground Fault Sensing Devices7 3.7 Delta Connected Systems 7 3.8 Neutra
15、ls and Grounding7 3.9 Need for Complete System Information7 3.10Systems Containing Transformers.8 3.11System Design .8 Section 4 CONTROL CIRCUIT.9 4.1 Control Power .9 4.2 AC Control Power .9 4.3 DC Control Power.9 4.4 Control Circuit Protection9 4.5 Control Wiring .9 4.6 Indication And Test Circuit
16、s9 4.7 Compatibility of GFP Devices.9 Section 5 TYPICAL APPLICATION DIAGRAMS10 5.1 General .10 5.1.1Abbreviations.10 5.2 Ground Fault Protection on Main Disconnect OnlyGround Return Type10 5.3 Ground Fault Protection on Main Disconnect OnlyOutgoing Circuit Type11 5.4 Ground Fault Protection on Main
17、And Feeder DisconnectsGround Return Type On Main 12 5.5 Ground Fault Protection on Main and Feeder DisconnectsOutgoing Circuit Type on Main 13 5.6 Ground Fault Protection On Main And Feeder Disconnects With Zone Selective InterlockingGround Return Type On Main.14 5.7 Ground Fault Protection On Main,
18、 Feeders, And Selected Branch Disconnects With Zone Selective InterlockingOutgoing Circuit Type On Main.15 5.8 Double-Ended System With Ground Fault Protection On Mains, Tie, And Feeder DisconnectsGround Return Type On Mains16 Section 6 TIME AND CURRENT SETTINGS .18 Copyright 2009 by the National El
19、ectrical Manufacturers Association. ? PB 2.2-1999 (R2004, R2009) Page ii 6.1 Application Of Ground Fault Protective Systems For Coordinated Ground Fault Tripping18 6.2 Types Of Coordinated Ground Fault Tripping Systems18 6.3 Time-Current Band Selective System.18 6.4 Zone Selective System .18 6.5 Coo
20、rdination of Low-Voltage Disconnects With The High-Voltage Side Of A System.19 6.6 Coordination with Downstream Overcurrent Devices Not Equipped With Ground Fault Protection.19 6.7 Typical Settings.19 6.7.1Single Zone-Ground Fault Protection on Main Disconnect Only20 6.7.2Multiple Zone Time Current
21、Band Selective System -Ground Fault Protection on Mains, Feeders, and Branch Circuits.22 6.7.3Zone Selective SystemGround Fault Protection on Mains and Feeders23 Section 7 TYPICAL COORDINATED SYSTEMS .25 7.1 Coordinated Protection.25 7.2 Examples 25 7.2.1GFP on Main Disconnect Only25 7.2.2GFP on Mai
22、n Disconnect and Feeders.26 7.2.3Fully Coordinated Multiple Zone Ground Fault Protection Systems.26 Section 8 TESTING OF GROUND FAULT SENSING AND RELAYING EQUIPMENT 27 8.1 Design Tests.27 8.2 Production Tests.27 8.3 Tests on Assembled Equipment.27 8.4 Preparation for Field Testing.27 8.5 Field Testi
23、ng28 Annex A ARCING FAULT DAMAGE LEVELS.29 A.1 APPROXIMATE ARCING FAULT DAMAGE LEVELS FOR 480Y/277 VOLT SYSTEMS29 A.2 ARCING FAULT CURRENT.29 A.3 ASSUMED TOLERABLE DAMAGE LEVELS.29 A.4 PROBABLE AMOUNT OF DAMAGE .30 Annex B SYSTEM DESIGN CONSIDERATIONS 33 B.1 GENERAL.33 B.2 POWER SYSTEM.33 B.3 GROUND
24、 FAULT CURRENT PATHS33 B.4 GROUND FAULT PROTECTIVE DEVICES AND SETTINGS.33 B.5 CONTROL POWER33 Copyright 2009 by the National Electrical Manufacturers Association. ? PB 2.2-1999 (R2004, R2009) Page iii Foreword This Standards Publication is intended to provide a basis of common understanding within