【BS英国标准】BS EN 13964-2004 Suspended ceilings — Requirements and test methods.pdf
《【BS英国标准】BS EN 13964-2004 Suspended ceilings — Requirements and test methods.pdf》由会员分享,可在线阅读,更多相关《【BS英国标准】BS EN 13964-2004 Suspended ceilings — Requirements and test methods.pdf(87页珍藏版)》请在三一文库上搜索。
1、BRITISH STANDARD BS EN 13964:2004 Suspended ceilings Requirements and test methods The European Standard EN 13964:2004 has the status of a British Standard ICS 91.060.30 ? Licensed copy:PONTYPRIDD COLLEGE, 29/08/2006, Uncontrolled Copy, BSI BS EN 13964:2004 This British Standard, was published under
2、 the authority of the Standards Policy and Strategy Committee on 23 August 2004 BSI 23 August 2004 ISBN 0 580 44323 X National foreword This British Standard is the official English language version of EN 13964:2004. It supersedes BS 8290-1:1991, BS 8290-2:1991 and BS 8290-3:1991 which are withdrawn
3、. EN 13964:2004 is a candidate “harmonized” European Standard and fully takes into account the requirements of the European Commission mandate M/121, Internal and external wall and ceiling finishes, given under the EU Construction Products Directive (89/106/EEC), and intended to lead to CE marking.
4、The date of applicability of EN 13964:2004 as a “harmonized” European Standard, i.e. the date after which this standard may be used for CE marking purposes, is subject to an announcement in the Official Journal of the European Communities. The Commission in consultation with Member States has agreed
5、 a transition period for the co-existence of “harmonized” European Standards and their corresponding national standard(s). It is intended that this period will comprise a period, usually nine months, after the date of availability of the European Standard, during which any required changes to nation
6、al regulations are to be made, followed by a further period, usually of 12 months, for the implementation of CE marking. At the end of this co-existence period, the national standard(s) will be withdrawn. EN 13964:2004 is the subject of transitional arrangements agreed under the Commission mandate.
7、In the UK, the corresponding national standards are: BS 8290-1:1991, Suspended ceilings Code of practice for design; BS 8290-2:1991, Suspended ceilings Specification for performance of components and assemblies; BS 8290-3:1991, Suspended ceilings Code of practice for installation and maintenance; an
8、d based on this transition period of twenty-one months, BS 8290-1:1991, BS 8290-2:1991 and BS 8290-3:1991 would be withdrawn in November 2005. NOTE This date is approximate. Users of this standard should contact BSI Customer Services for confirmation of withdrawal. The UK participation in the prepar
9、ation of BS EN 13964:2004 was entrusted to Technical Committee B/548, Suspended ceilings, which has the responsibility to: A list of organizations represented on this committee can be obtained on request to its secretary. aid enquirers to understand the text; present to the responsible international
10、/European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. Amendments issued since publication Amd. No. DateComments Licensed copy:PONTYPRIDD COLLEGE, 29/
11、08/2006, Uncontrolled Copy, BSI BS EN 13964:2004 i Additional information Technical Committee B/548 would like to highlight that the scope of EN 13964:2004 as written does not exclude monolithic suspended ceilings that are comprised of gypsum boards and concealed metal framing that are of a non-demo
12、untable nature. Attention is drawn to the fact that there are specific European Standards in preparation that cover monolithic suspended ceilings, which include the following: prEN 520, Gypsum plasterboards Definitions, requirements and test methods; prEN 13815, Fibrous gypsum plaster products Defin
13、itions, requirements and test methods; prEN 14190, Gypsum plasterboard products from reprocessing Definitions, requirements and test methods; prEN 14195, Metal framing components for gypsum plasterboard systems Definitions, requirements and test methods; prEN 14246, Gypsum elements for suspended cei
14、lings Definitions, requirements and test methods. In addition there is: WI 00241040, Fibre reinforced gypsum sheet products Part 1: Mat reinforced gypsum boards; WI 00241041, Fibre reinforced gypsum sheet products Part 2: Gypsum boards with dispersed fibre reinforcement. Cross-references The British
15、 Standards which implement international or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online
16、. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an insid
17、e front cover, pages i and ii, the EN title page, pages 2 to 81 and a back cover. The BSI copyright notice displayed in this document indicates when the document was last issued. Licensed copy:PONTYPRIDD COLLEGE, 29/08/2006, Uncontrolled Copy, BSI ii Licensed copy:PONTYPRIDD COLLEGE, 29/08/2006, Unc
18、ontrolled Copy, BSI w w w . b z f x w . c o m EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 13964 March 2004 ICS 91.060.30 English version Suspended ceilings - Requirements and test methods Plafonds suspendus - Exigences et mthodes dessaiUnterdecken - Anforderungen und Prfverfahren This Europ
19、ean Standard was approved by CEN on 3 November 2003. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references co
20、ncerning such national standards may be obtained on application to the Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own
21、 language and notified to the Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg
22、, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: rue de Stassart, 36 B-1050 Brussels 2004 CENAll rights of exploit
23、ation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 13964:2004 E Licensed copy:PONTYPRIDD COLLEGE, 29/08/2006, Uncontrolled Copy, BSI w w w . b z f x w . c o m EN 13964:2004 (E) 2 ContentsPage 1Scope 4 2Normative references 5 3Terms and definitions7 3.1General
24、7 3.2Suspended ceiling and substructure components (see Figure 1).8 3.3Ceiling membranes and ceiling membrane components9 3.4Typical suspended ceiling assemblies using volume or thin gauge materials 12 4Requirements.16 4.1Material and products General16 4.2Modular dimensions16 4.3Mechanical resistan
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS英国标准 【BS英国标准】BS EN 13964-2004 Suspended ceilings Requirements and test methods BS 英国 标准 13964 2004
链接地址:https://www.31doc.com/p-3694587.html