1、BS 5871-4:2007 Specification for the installation and maintenance of gas fires, convector heaters, fire/back boilers and decorative fuel effect appliances Part 4: Independent gas-fired flueless fires, convector heaters and heating stoves of nominal heat input not exceeding 6 kW (2nd and 3rd family g
2、ases) ICS 97.100.20 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW BRITISH STANDARD Licensed copy:PONTYPRIDD COLLEGE, 12/01/2008, Uncontrolled Copy, BSI Publishing and copyright information The BSI copyright notice displayed in this document indicates when the document was la
3、st issued. BSI 2007 ISBN 978 0 580 53949 7 The following BSI references relate to the work on this standard: Committee reference GSE/30 Draft for comment 06/30096954 DC Publication history First published July 2007 Amendments issued since publication Amd. no.DateText affected BS 5871-4:2007 Licensed
4、 copy:PONTYPRIDD COLLEGE, 12/01/2008, Uncontrolled Copy, BSI w w w . b z f x w . c o m BSI 2007i BS 5871-4:2007 Contents Foreword iii 1Scope 1 2Normative references 2 3Terms and definitions 3 4Exchange of information and planning 4 5Appliances 7 6Materials and components 8 7Location 10 8Appliance si
5、zing and ventilation 10 9Appliance fixing 13 10Fire precautions 15 11Gas supply 19 12Electricity supplies and wiring 21 13Commissioning 21 14Instructions and use of fireguards 22 15Advice to be given to the user 22 Annexes Annex A (informative) Guidance on ventilation requirements for flueless gas f
6、ires 25 Bibliography 29 List of figures Figure 1 Examples of flueless appliances 9 Figure 2 General layout of a raised builders opening installation (hole-in-the-wall fireplace) 18 Figure 3 Typical unconcealed gas supply system to a gas fire 20 Summary of pages This document comprises a front cover,
7、 an inside front cover, pages i to iv, pages 1 to 30, an inside back cover and a back cover. Licensed copy:PONTYPRIDD COLLEGE, 12/01/2008, Uncontrolled Copy, BSI w w w . b z f x w . c o m BS 5871-4:2007 ii BSI 2007This page deliberately left blank Licensed copy:PONTYPRIDD COLLEGE, 12/01/2008, Uncont
8、rolled Copy, BSI w w w . b z f x w . c o m BSI 2007iii BS 5871-4:2007 Foreword Publishing information This part of BS 5871 was published by BSI and comes into effect on publication of BS EN 14829;1) the intervening time constitutes the implementation period of BS 5871-4. It was prepared by GSE/30/-/
9、4, under the authority of GSE/30, Gas Installations (1st, 2nd and 3rd family gases). A list of organizations represented on this committee can be obtained on request to its secretary. This part of BS 5871 covers the installation of independent gas-fired flueless fires, convector heaters and heating
10、stoves of nominal heat input not exceeding 6 kW (2nd and 3rd family gases). Installation of convector heaters in greenhouses as greenhouse heaters is only covered in respect of single appliance installations. BS 5871, Specification for the installation and maintenance of gas fires, convector heaters
11、, fire/back boilers and decorative fuel effect gas appliances, consists of the following parts: BS 5871-1: Gas fires, convector heaters, fire/back boilers and heating stoves (2nd and 3rd family gases). BS 5871-2: Inset live fuel effect gas fires of heat input not exceeding 15 kW and fire/back boiler
12、s (2nd and 3rd family gases). BS 5871-3: Decorative fuel effect gas appliances of heat input not exceeding 20 kW (2nd and 3rd family gases). BS 5871-4: Independent gas-fired flueless fires, convector heaters and heating stoves of nominal heat input not exceeding 6 kW (2nd and 3rd family gases). It s
13、hould be noted that the only appliances covered by this part of BS 5871 are those that are “CE” marked. However, BS 5871-4 may also be referred to for the installation of used appliances, where appropriate, providing the manufacturers instructions are available. In such circumstances, the installer
14、should satisfy himself that the appliance is safe in construction and condition, and can be used without constituting a danger. Attention is drawn to Clause 5 concerning this particular aspect. This standard allows manufacturers instructions to specify a method of installation, testing, commissionin
15、g or maintenance which differs in points of detail from this standard. This reference to manufacturers instructions is allowed only where it will result in at least an equivalent level of safety. In such circumstances, it is important that the manufacturers instructions are followed. Although BS 587
16、1-4 is an appliance installation standard, the drafting panel has decided to include an informative Annex A providing guidance for notified bodies and manufacturers on assessing ventilation requirements for flueless gas fires. 1) Users will be informed by BSI of the publication of BS EN 14829. Licen
17、sed copy:PONTYPRIDD COLLEGE, 12/01/2008, Uncontrolled Copy, BSI w w w . b z f x w . c o m BS 5871-4:2007 iv BSI 2007 Presentational conventions The provisions of this standard are presented in roman (i.e. upright) type. Its requirements are expressed in sentences in which the principal auxiliary ver
18、b is “shall”. Commentary, explanation and general informative material is presented in notes in smaller italic type. To comply with this standard, the user has to comply with all its requirements. The user may depart from recommendations, but this would be the users own responsibility and they would
19、 be expected to have a good reason for doing so. Contractual and legal considerations This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard cannot confer immunity from legal oblig
20、ations. In particular, attention is drawn to the following statutory regulations. The Gas Safety (Installation and Use) Regulations 1998 1 The Gas Safety (Installation and Use) Regulations (Northern Ireland) 2004 2 The Gas Appliances (Safety) Regulations 1995 3 The Building Regulations 2000, as amen
21、ded 4 The Building (Scotland) Regulations 2004 5 The Building Regulations (Northern Ireland) Statutory Rules 2000, as amended 6 The Gas Safety (Application) (Isle of Man) Order 1996 7 The Health and Safety (Gas) (Guernsey) Ordinance 2006 8 Licensed copy:PONTYPRIDD COLLEGE, 12/01/2008, Uncontrolled C
22、opy, BSI w w w . b z f x w . c o m BSI 20071 BS 5871-4:2007 1 Scope This part of BS 5871 specifies installation and maintenance requirements for independent gas-fired flueless fires, convector heaters and heating stoves of nominal heat input not exceeding 6 kW burning 2nd and 3rd family gases for th
23、e purpose of heating rooms or internal spaces in domestic (see note 3) or commercial premises. Specifically, it covers: a)fixed appliances that satisfy all the requirements of BS EN 14829; b)fixed appliances that satisfy the combustion requirements of BS EN 14829; c)convector heaters of nominal heat
24、 input not exceeding 4.2 kW in the form of greenhouse heaters in respect of single appliance installations. NOTE 1 Appliances a) and b) are only intended as a secondary heat source (see Commentary and Recommendations on 4.2). The heat input and ventilation, fixing and gas supply for convector heater