07-30164989-DC.pdf
《07-30164989-DC.pdf》由会员分享,可在线阅读,更多相关《07-30164989-DC.pdf(24页珍藏版)》请在三一文库上搜索。
1、a Date: 20 April 2007 Origin: International Latest date for receipt of comments: 31 July 2007 Project no.: 2007/00977 Responsible committee: EPL/501 Electronic assembly technology Interested committees: Title: Draft BS EN 61249-2-36 ED.1 Materials for printed boards and other interconnecting structu
2、res - Part 2-36: Reinforced base materials clad and unclad - Epoxide woven E-glass laminated sheets of defined flammability (vertical burning test), copper-clad for lead-free assembly Supersession information: If this document is published as a standard, the UK implementation of it will supersede NO
3、NE and partially supersede. NONE If you are aware of a current national standard which may be affected, please notify the secretary (contact details below). WARNING: THIS IS A DRAFT AND MUST NOT BE REGARDED OR USED AS A BRITISH STANDARD. THIS DRAFT IS NOT CURRENT BEYOND 31 July 2007. This draft is i
4、ssued to allow comments from interested parties; all comments will be given consideration prior to publication. No acknowledgement will normally be sent. See overleaf for information on commenting. No copying is allowed, in any form, without prior written permission from BSI except as permitted unde
5、r the Copyright, Designs and Patent Act 1988 or for circulation within a nominating organization for briefing purposes. Electronic circulation is limited to dissemination by e-mail within such an organization by committee members. Further copies of this draft may be purchased from BSI Customer Servi
6、ces, Tel: +44(0) 20 8996 9001 or email ordersbsi-. British, International and foreign standards are also available from BSI Customer Services. British Standards on CD or Online are available from British Standards Publishing Sales Limited. Tel: 01344 404409 or email bsonlinetechindex.co.uk. Informat
7、ion on the co-operating organizations represented on the committees referenced above may be obtained from the responsible committee secretary. Cross-references The British Standards which implement International or European publications referred to in this draft may be found via the British Standard
8、s Online Service on the BSI web site http:/www.bsi-. Direct tel: 020 8996 7205 Responsible Committee Secretary: Mr A Ashrafi (BSI) E-mail: asghar.ashrafibsi- Draft for Public Comment Head Office 389 Chiswick High Road London W4 4AL Telephone: +44(0)20 8996 9000 Fax: +44(0)20 8996 7001 Form 36 Versio
9、n 7.0 DPC: 07/30164989 DC Licensed Copy: London South Bank University, London South Bank University, Mon May 07 12:31:10 GMT+00:00 2007, Uncontrolled Copy, (c) BSI b Introduction This draft standard is based on international discussions in which the UK has taken an active part. Your comments on this
10、 draft are welcome and will assist in the preparation of the consequent standard. If no comments are received to the contrary, then the UK will approve this draft. There is a high probability that this text could be adopted by CENELEC as a reference document for harmonization or as a European Standa
11、rd. Recipients of this draft are requested to comment on the text bearing in mind this possibility. UK Vote Please indicate whether you consider the UK should submit a negative (with reasons) or positive vote on this draft. Submission The guidance given below is intended to ensure that all comments
12、receive efficient and appropriate attention by the responsible BSI committee. Annotated drafts are not acceptable and will be rejected. All comments must be submitted, preferably electronically, to the Responsible Committee Secretary at the address given on the front cover. Comments should be compat
13、ible with Version 6.0 or Version 97 of Microsoft Word for Windows, if possible; otherwise comments in ASCII text format are acceptable. Any comments not submitted electronically should still adhere to these format requirements. All comments submitted should be presented as given in the example below
14、. Further information on submitting comments and how to obtain a blank electronic version of a comment form are available from the BSI web site at: http:/www.bsi- Template for comments and secretariat observations Date: xx/xx/200x Document: ISO/DIS xxxxx 1 2 (3) 4 5 (6) (7) MB Clause No./ Subclause
15、No./ Annex (e.g. 3.1) Paragraph/ Figure/Table/ Note (e.g. Table 1) Type of com- ment Comment (justification for change) by the MB Proposed change by the MB Secretariat observations on each comment submitted 3.1 Definition 1 ed Definition is ambiguous and needs clarifying. Amend to read . so that the
16、 mains connector to which no connection . 6.4 Paragraph 2 te The use of the UV photometer as an alternative cannot be supported as serious problems have been encountered in its use in the UK. Delete reference to UV photometer. Microsoft and MS-DOS are registered trademarks, and Windows is a trademar
17、k of Microsoft Corporation. Licensed Copy: London South Bank University, London South Bank University, Mon May 07 12:31:10 GMT+00:00 2007, Uncontrolled Copy, (c) BSI FORM CDV (IEC) 2005-09-23 91/657/CDV COMMITTEE DRAFT FOR VOTE (CDV) PROJET DE COMIT POUR VOTE (CDV) Project number IEC 61249-2-36, Ed.
18、 1 Numro de projet IEC/TC or SC: TC 91 CEI/CE ou SC: Secretariat / Secrtariat Japan Submitted for parallel voting in CENELEC Soumis au vote parallle au CENELEC Date of circulation Date de diffusion 2007-04-06 Closing date for voting (Voting mandatory for P-members) Date de clture du vote (Vote oblig
19、atoire pour les membres (P) 2007-09-07 Also of interest to the following committees Intresse galement les comits suivants Supersedes document Remplace le document 91/656/NP Functions concerned Fonctions concernes Safety Scurit EMC CEM Environment Environnement Quality assurance Assurance qualit CE D
20、OCUMENT EST TOUJOURS LTUDE ET SUSCEPTIBLE DE MODIFICATION. IL NE PEUT SERVIR DE RFRENCE. LES RCIPIENDAIRES DU PRSENT DOCUMENT SONT INVITS PRSENTER, AVEC LEURS OBSERVATIONS, LA NOTIFICATION DES DROITS DE PROPRIT DONT ILS AURAIENT VENTUELLEMENT CONNAISSANCE ET FOURNIR UNE DOCUMENTATION EXPLICATIVE. TH
21、IS DOCUMENT IS STILL UNDER STUDY AND SUBJECT TO CHANGE. IT SHOULD NOT BE USED FOR REFERENCE PURPOSES. RECIPIENTS OF THIS DOCUMENT ARE INVITED TO SUBMIT, WITH THEIR COMMENTS, NOTIFICATION OF ANY RELEVANT PATENT RIGHTS OF WHICH THEY ARE AWARE AND TO PROVIDE SUPPORTING DOCUMENTATION. Titre : Title : IE
22、C 61249-2-36, Ed. 1: Materials for printed boards and other interconnecting structures - Part 2-36: Reinforced base materials clad and unclad Epoxide woven E-glass laminated sheets of defined flammability (vertical burning test), copper-clad for lead-free assembly Note dintroduction Introductory not
23、e Ce CDV est diffus selon la procdure indique dans le doc. AC/8/2003 selon laquelle un NP est diffus en parallle avec son CDV. This CDV is issued in application of the procedure in AC/8/2003 for the simultaneous submission of a NP and its CDV. If the 91/656/NP is accepted, this CDV ballot will conti
24、nue and the project will be considered as being at CDV stage. If the NP is not approved, CDV ballot will be cancelled. ATTENTION VOTE PARALLLE CEI CENELEC Lattention des Comits nationaux de la CEI, membres du CENELEC, est attire sur le fait que ce projet de comit pour vote (CDV) de Norme internation
- 配套讲稿: