ANSI-ASHRAE-90.1-2004-SI-ERTA-2007(0529).pdf
《ANSI-ASHRAE-90.1-2004-SI-ERTA-2007(0529).pdf》由会员分享,可在线阅读,更多相关《ANSI-ASHRAE-90.1-2004-SI-ERTA-2007(0529).pdf(7页珍藏版)》请在三一文库上搜索。
1、Page 1 of 7 2007 ASHRAE. All rights reserved. ERRATA SHEET FOR THE FIRST PRINTING OF ANSI/ASHRAE/IESNA STANDARD 90.1-2004 (SI edition) Energy Standard for Buildings Except Low-Rise Residential Buildings May 29, 2007 The corrections listed in this errata sheet apply to the first printing of ANSI/ASHR
2、AE/IESNA Standard 90.1-2004, SI edition, identified as “86248 PC 1/05”on the outside back cover of the standard. Shaded items have been added since the previously published errata sheet dated May 1, 2007 was distributed. More than one errata sheet may be required for a specific document. Please revi
3、ew the entire list on the ASHRAE website related to the applicable document and download all that apply. NOTICE: ASHRAE now has a list server for Standing Standards Project Committee 90.1 (SSPC 90.1). Interested parties can now subscribe and unsubscribe to the list server and be automatically notifi
4、ed via e-mail when activities and information related to the Standard and the Users Manual is available. To sign up for the list server please visit Project Committee List Servers for Standard on the Technology / Standards section of the ASHRAE website at http:/www.ashrae.org/publications/detail/156
5、20. Page(s) Erratum 6 Section 3.2 Definitions. Change (a) and (b) in the definition for degree-day to read as follows: (Note: Additions are shown in underline and deletions are shown in strikethrough.) degree-day: the difference in temperature between the outdoor mean temperature over a 24-hour peri
6、od and a given base temperature. For the purposes of determining building envelope requirements, the classifications are defined as follows: (a) cooling degree-day base 10C, CDD10: for any one day, when the mean temperature is more than 10C, there are as many degree-days as degrees CelsiusFahrenheit
7、 temperature difference between the mean temperature for the day and 10C. Annual cooling degree-days (CDDs) are the sum of the degree- days over a calendar year. (b) heating degree-day base 18C, HDD18: for any one day, when the mean temperature is less than 18C, there are as many degree-days as degr
8、ees CelsiusFahrenheit temperature difference between the mean temperature for the day and 18C. Annual heating degree-days (HDDs) are the sum of the degree- days over a calendar year. 15 Section 3.3 Abbreviations and Acronyms. Change CTI from “Cooling Tower Institute” to “Cooling Technology Institute
9、”. 17 Section 5. Building Envelope. In the compliance path figure at the beginning of Section 5 correct the spelling of prescriptive so it reads “5.5 Prescriptive Path”. 19 Table 5.5.3.1. Change the title of Table 5.5.3.1 as follows: (Note: Additions are shown in underline and deletions are shown in
10、 strikethrough.) Page 2 of 7 2007 ASHRAE. All rights reserved. Roof U-Factor Multipliers for Exception to 5.5.1.1 5.5.3.1 22 through 30 TABLES 5.5-1 through 5.5-8 Building Envelope Requirements. Add a footnote to the bottom of Tables 5.5-1 through 5.5-8 as follows: “The following definitions apply: