AAMA-101-UPD-1-2007.pdf
《AAMA-101-UPD-1-2007.pdf》由会员分享,可在线阅读,更多相关《AAMA-101-UPD-1-2007.pdf(26页珍藏版)》请在三一文库上搜索。
1、Update No. 1 AAMA/WDMA/CSA 101/I.S.2/A440-05 March 2007 Note: General Instructions for CSA Standards are now called Updates. Please contact CSA Information Products Sales or visit www.ShopCSA.ca for information about the CSA Standards Update Service. Title: Standard/Specification for windows, doors,
2、 and unit skylights originally published February 2005 The following revisions have been formally approved and are marked by the symbol delta () in the margin on the attached replacement pages: AAMA/WDMA/CSA 101/I.S.2/A440-05 originally consisted of 129 pages (x preliminary and 119 text), each dated
3、 February 2005. It now consists of the following pages: Update your copy by inserting these revised pages. Keep the pages you remove for reference. RevisedContents, Clauses 3, 4.4.2.6.1, 5.3.1.2, 5.3.6.10, 5.3.6.11, and 6.2.1, Tables 6, 17, and 25, and Figure 6 (second-last diagram) NewClause 6.2.3.
4、4.6 DeletedNone February 2005vx, 118, 2134, 3950, 5370, 75, 76, 79, 80, 83110, and 115119 March 2007iii, iv, 19, 20, 3538, 51, 52, 7174, 77, 78, 8182A, and 111114 Copyright Canadian Standards Association Provided by IHS under license with CSA Licensee=IHS Employees/1111111001, User=Japan, IHS Not fo
5、r Resale, 01/22/2008 23:41:09 MSTNo reproduction or networking permitted without license from IHS -,-,- Copyright Canadian Standards Association Provided by IHS under license with CSA Licensee=IHS Employees/1111111001, User=Japan, IHS Not for Resale, 01/22/2008 23:41:09 MSTNo reproduction or network
6、ing permitted without license from IHS -,-,- Contents American Architectural Manufacturers Association Window or (b)another specimen of any size shall be permitted to be tested. If the specimen is smaller in width or height than the gateway size, an asterisk (*) shall be appended to the size designa
7、tion (MST). (See Figure 3.) If the size of the additional specimen is larger in width or height than the gateway specimen size, then all tests in Clause 5 applicable to the product type shall be conducted. 4.4.2.6.2 Clause 4.4.2.6.1 shall be used in conjunction with Clause 8. All products tested und
8、er Clause 4.4.2.6.1 shall be required to conform to all of the particular requirements of Clauses 5 to 8 and Table 25 for the product designation under consideration. Prior to being considered for an optional performance grade (design pressure), a product shall (a)comply with the general requirement
9、s of Clauses 5 to 7; (b)comply with the gateway performance requirements for the minimum performance grade listed in Clause 8; (c)comply with all of the specific product performance requirements specified in Clause 8 for that product type; and (d)comply with all of the appropriate material and compo
10、nent requirements specified in Clauses 6 and 7. After complying with all of the specified minimum requirements at the minimum gateway test size or larger test size for a product, the product shall be permitted to be tested in any test size for conformance to an optional performance grade (design pre
11、ssure), within the same performance class, in multiple increments of 240 Pa (5.0 psf), as specified in Table 3. Optional performance grades (design pressures) shall not be allowed to exceed the minimum performance grades for design pressures greater than the gateway design pressure for the performan
12、ce class by more than 2880 Pa (60.0 psf) except in the case of the highest performance class indicated in Tables 25 and 26 for each operator type. For example, R products shall not be rated at a design pressure greater than 3600 Pa (75.0 psf). LC products shall be capped at 4080 Pa (85.0 psf). C pro
13、ducts shall be capped at 4320 Pa (90.0 psf), and HC products shall be capped at 4800 Pa (100 psf). AW product optional performance grades (design pressures) shall never be capped. See Clause 5.1 for testing sequence. 37(Replaces p. 37, February 2005) Copyright Canadian Standards Association Provided
14、 by IHS under license with CSA Licensee=IHS Employees/1111111001, User=Japan, IHS Not for Resale, 01/22/2008 23:41:09 MSTNo reproduction or networking permitted without license from IHS -,-,- March 2007 American Architectural Manufacturers Association Window B is the area of the tested sash in squar
15、e feet. 71(Replaces p. 71, February 2005) Copyright Canadian Standards Association Provided by IHS under license with CSA Licensee=IHS Employees/1111111001, User=Japan, IHS Not for Resale, 01/22/2008 23:41:09 MSTNo reproduction or networking permitted without license from IHS -,-,- March 2007 Americ
16、an Architectural Manufacturers Association Window (b)heat-absorbing glass: CAN/CGSB 12.4; (c)spandrel glass: CAN/CGSB 12.9; (d)light- and heat-reflecting glass: CAN/CGSB 12.10; (e)laminated glass: ASTM C 1172 or CAN/CGSB 12.1; (f)heat-treated glass: ASTM C 1048 or CAN/CGSB 12.1; (g)safety glazing: A
17、NSI Z97.1, 16 CFR 1201, and CAN/CGSB 12.1; (h)wired safety glass: CAN/CGSB 12.11; (i)sealed insulating glass units: ASTM E 774, ASTM E 2190, or CAN/CGSB 12.8; and (j)plastic glazing: ANSI Z97.1, 16 CFR 1201, and CAN/CGSB 12.12. Note: Most building codes require safety glazing to be used in door syst
18、ems, unit skylights, and some windows in certain applications. Consult local codes for details. 6.2.2 General requirements The uniform load resistance (design pressure rating) of glazing furnished by the manufacturer shall meet or exceed the specified design pressure selected by the specifier. Where
19、 applicable, load resistance of the glazing shall be determined by ASTM E 1300 (applicable to one-, two-, three-, or four-sided firm support) or CAN/CGSB 12.20 (applicable to four-sided firm support only), with factors for heat-treated, laminated, and insulating glass load duration, etc., as applica
20、ble. Note: Sealed insulating glass units should be glazed in a manner that precludes the accumulation of water in the glazing cavity. If “dry” glazing is employed as the exterior seal, drainage of the glazing cavity to the exterior should be provided. Sealed insulating glass units shall conform to t
21、he requirements of ASTM E 774, Level A; CAN/CGSB 12.8; or ASTM E 2190. Note: On commercial projects, the architect or buyer will often specify the glazing. On residential projects, glazing selection, to meet the design pressure for the project is often deferred to the manufacturer. In either case, t
22、he selector should specify glazing in conformance with the Standards specified in Clause 6.2.1 and this Clause, as applicable. 6.2.3 Glazing selection 6.2.3.1 General Glazing selection is dependent on whether selection is being made for testing purposes or to meet required structural loads. When gla
23、zing selection is being made for the purpose of testing a fenestration assembly, it is the intent of this Standard/Specification that the glazing should be of a type intended for 77(Replaces p. 77, February 2005) Copyright Canadian Standards Association Provided by IHS under license with CSA License
24、e=IHS Employees/1111111001, User=Japan, IHS Not for Resale, 01/22/2008 23:41:09 MSTNo reproduction or networking permitted without license from IHS -,-,- March 2007 American Architectural Manufacturers Association Window (b)composite material panels; and (c)wired safety glass. Under this exception,
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AAMA 101 UPD 2007
链接地址:https://www.31doc.com/p-3729025.html