AS-1361-1995.pdf
《AS-1361-1995.pdf》由会员分享,可在线阅读,更多相关《AS-1361-1995.pdf(31页珍藏版)》请在三一文库上搜索。
1、AS 13611995 (Incorporating Amendment No. 1) Australian Standard Electric heat-exchange water heaters For domestic applications AS 13611995 Accessed by UNIVERSITY OF SOUTH AUSTRALIA on 17 Sep 2007 This Australian Standard was prepared by Committee EL-020, Electric Water Heating Appliances. It was app
2、roved on behalf of the Council of Standards Australia on 23 December 1994. This Standard was published on 5 March 1995. The following are represented on Committee EL-020: Association of Certification Bodies Australian Chamber of Commerce and Industry Australian Electrical and Electronic Manufacturer
3、s Association Australian Gas Association Australian Stainless Steel Development Association Electricity Supply Association of Australia Engineering and Water Supply Department, S.A. Heat Exchange Water Heater Manufactures Association Metal Trades Industry Association of Australia National Appliance
4、Energy Efficiency Co-ordinating Committee Keeping Standards up-to-date Standards are living documents which reflect progress in science, technology and systems. To maintain their currency, all Standards are periodically reviewed, and new editions are published. Between editions, amendments may be is
5、sued. Standards may also be withdrawn. It is important that readers assure themselves they are using a current Standard, which should include any amendments which may have been published since the Standard was purchased. Detailed information about Standards can be found by visiting the Standards Web
6、 Shop at .au and looking up the relevant Standard in the on-line catalogue. Alternatively, the printed Catalogue provides information current at 1 January each year, and the monthly magazine, The Global Standard, has a full listing of revisions and amendments published each month. Australian Standar
7、dsTM and other products and services developed by Standards Australia are published and distributed under contract by SAI Global, which operates the Standards Web Shop. We also welcome suggestions for improvement in our Standards, and especially encourage readers to notify us immediately of any appa
8、rent inaccuracies or ambiguities. Contact us via email at mailstandards.org.au, or write to the Chief Executive, Standards Australia, GPO Box 476, Sydney, NSW 2001. This Standard was issued in draft form for comment as DR 93040. Accessed by UNIVERSITY OF SOUTH AUSTRALIA on 17 Sep 2007 AS 13611995 (I
9、ncorporating Amendment No. 1) Australian Standard Electric heat-exchange water heaters For domestic applications First published as AS C4091971. Revised and redesignated AS 13611973. Second edition 1995. Reissued incorporating Amendment No. 1 (2005) COPYRIGHT Standards Australia All rights are reser
10、ved. No part of this work may be reproduced or copied in any form or by any means, electronic or mechanical, including photocopying, without the written permission of the publisher. Published by Standards Australia, GPO Box 476, Sydney, NSW 2001, Australia ISBN 0 7262 9591 4 Accessed by UNIVERSITY O
11、F SOUTH AUSTRALIA on 17 Sep 2007 AS 13611995 2 PREFACE This Standard was prepared by the Joint Standards Australia/New Zealand Committee EL-020 on Electric Water Heating Appliances to supersede AS 13611973, Automatic electric heat exchange water heaters. This Standard incorporates Amendment No. 1 (S
12、eptember 2005). The changes required by the Amendment are indicated in the text by a marginal bar and amendment number against the clause, note, table, figure or part thereof affected. This Standard is the result of a consensus among representatives on the Joint Committee to produce it as an Austral
13、ian Standard. This edition is restricted to water heaters intended for domestic situations and incorporates a heat loss test similar in principle to the test used in AS 1056.1, Storage water heaters, Part 1: General requirements, and includes other changes made to align more closely with AS 1056.1.
14、This Standard has been amended to incorporate key changes that will improve the accuracy of the existing methods of test for MEPS heat loss testing to acceptable levels. AS/NZS 4692.1, Electric water heaters, Part 1: Energy consumption, performance and general requirements, sets out a new test metho
15、d for MEPS heat loss testing. This amended Standard will remain current until confidence and experience have been gained with AS/NZS 4692.1, after which time it will be superseded by AS/NZS 4692.1 and AS/NZS 4692.2, Electric water heaters, Part 2: Minimum Energy Performance Standards (MEPS) requirem
16、ents and energy labelling. The new regulatory Standard AS/NZS 4692.2 will allow testing to either the amended AS 1056.1, Storage water heaters, Part 1: General requirements or AS 1361, Electric heat- exchange water heatersFor domestic applications, as applicable, or to AS/NZS 4692.1. MEPS levels, as
17、 defined under each test method, are provided in AS/NZS 4692.2. The key elements included in Amendment 1 are as follows: Energy correction at the thermostat cut-out. Shielding of the water heater from other objects under test that have a temperate difference of greater than 5 K. Mounting the water h
18、eater on a wooden platform when testing. A cement sheet is also an acceptable mounting. 24 h stabilization plus 48 h test period. Product specification to be supplied with the test report. Frequency of sampling for air and water temperature measurements to be reduced to an acceptable period (5 min o
19、r less). The terms normative and informative have been used in this Standard to define the application of the appendix to which they apply. A normative appendix is an integral part of a Standard, whereas an informative appendix is only for information and guidance. A1 Accessed by UNIVERSITY OF SOUTH
20、 AUSTRALIA on 17 Sep 2007 3 AS 13611995 CONTENTS Page SECTION 1 SCOPE AND GENERAL 1.1 SCOPE 4 1.2 REFERENCED DOCUMENTS 4 1.3 DEFINITIONS 5 SECTION 2 DESIGN AND CONSTRUCTION 2.1 COMPLIANCE WITH OTHER SPECIFICATIONS 6 2.2 MAINTENANCE6 2.3 MATERIALS IN CONTACT WITH POTABLE WATER6 2.4 HEAT-STORAGE VOLUM
21、E .6 2.5 HOT WATER DELIVERY .6 2.6 MECHANICAL PROPERTIES OF CONTAINER6 2.7 THERMAL INSULATION .6 2.8 CORSET7 2.9 CASING7 2.10 HEAT EXCHANGER .7 2.11 EXPANSION CONTROL VALVE.8 2.12 WATER FITTINGS 8 2.13 MAINTENANCE OF STATIC WATER LEVEL8 2.14 OVERFLOW.8 2.15 DRAINAGE FACILITIES.8 2.16 VENT8 2.17 ABIL
22、ITY TO WITHSTAND HYDROSTATIC PRESSURE 8 2.18 WATERTIGHTNESS9 2.19 ABILITY TO WITHSTAND EXTERNAL TORQUE.9 SECTION 3 ELECTRICAL COMPONENTS 10 SECTION 4 MARKING 4.1 GENERAL 11 4.2 BOOSTING UNIT. 11 SECTION 5 INSTALLATION AND MAINTENANCE INSTRUCTIONS. 12 SECTION 6 DETERMINATION OF COMPLIANCE 6.1 TYPE TE
23、STS 13 6.2 ROUTINE TESTS. 13 APPENDICES A INFORMATION TO BE SUPPLIED WITH ENQUIRIES AND ORDERS 14 B METHOD FOR DETERMINING HOT-WATER DELIVERY. 15 C METHOD FOR DETERMINING HEAT LOSS 18 D TYPICAL PRODUCT SPECIFICATION . 22 Accessed by UNIVERSITY OF SOUTH AUSTRALIA on 17 Sep 2007 AS 13611995 4 Standard
24、s Australia .au STANDARDS AUSTRALIA Australian Standard Electric heat-exchange water heatersFor domestic applications S E C T I O N 1 S C O P E A N D G E N E R A L 1.1 SCOPE This Standard specifies requirements for electric heat-exchange water heaters having a heat- storage volume in the range of 45