ASSE-1002-1999.pdf
《ASSE-1002-1999.pdf》由会员分享,可在线阅读,更多相关《ASSE-1002-1999.pdf(21页珍藏版)》请在三一文库上搜索。
1、ASSE Standard #lo02 ASSE Board of Directors Approved: 1999 American Society o f Sanitary Engineering Performance Requirements for Anti-siphon Fill Valves (Ballcocks) for Gravity Water Closet Flush Tanks Copyright American Society of Sanitary Engineering Provided by IHS under license with ASSE Licens
2、ee=University of Texas/5626000001 Not for Resale, 12/24/2006 00:23:05 MSTNo reproduction or networking permitted without license from IHS -,-,- General Information Neitherthis standard, nor any portion thereof, may be reproduced without the written consent of the American Society of Sanitary Enginee
3、ring. No product may be said to be ASSE approved unless the manufacturer has applied to the ASSE has had his product tested according to the applicable ASSE Standards, and when the product has passed the test, displays the ASSE Seal on the product. Instructions for receiving the authorization to dis
4、play the Seal are available from ASSE Central Office. Organizations wishing to adopt or list any ASSE Standard should print the ASSE Standard Number on the cover page first and in equal or larger type to that of the adopting or listing organization. American Society of Sanitary Engineering Westlake,
5、 Ohio Copyright O 1999, 1986,1979, 1976 All rights reserved. Anti-siphon Fill Valves (Ballcocks) for Gravity Water Closet Flush Tanks ASSE #I002 Revised: 1999 i Copyright American Society of Sanitary Engineering Provided by IHS under license with ASSE Licensee=University of Texas/5626000001 Not for
6、Resale, 12/24/2006 00:23:05 MSTNo reproduction or networking permitted without license from IHS -,-,- Anti-siphon Fill Valves (Ballcocks) for Gravity Water Closet Flush Tanks ASSE #I002 Revised: 1999 Copyright American Society of Sanitary Engineering Provided by IHS under license with ASSE Licensee=
7、University of Texas/5626000001 Not for Resale, 12/24/2006 00:23:05 MSTNo reproduction or networking permitted without license from IHS -,-,- orewo rd This foreword shall not be considered a part of the standard, however, it is offered to provide background information. ASSE Standards are developed i
8、n the interest of consumer safety. While this standard outlines the performance requirementsfor Anti-siphon FillValves (Ballcocks) for Gravity Water Closet Flush Tanks, and describes those performance requirements in terms of methods of testing applicable to all such units, equivalent materials or m
9、ethods of testing intended to demonstrate compliance with these requirements are also acceptable. Further- more, while common design, types and sizes may be defined or stated throughout this document for the basis of standardization with other industry components, or other designs, types and sizes w
10、hich may comply with the intent of the standard may also be submitted. Recognition is made of the time volunteered by members of the working group and of the support of the manufacturers who also participated in the meetings for this standard. This standard does not imply ASSES endorsement of a prod
11、uct which conforms to these req u i remen ts . Compliance with this standard does not imply acceptance by any code body. It is recommended that these devices be installed consistent with local codes by qualified and trained professionals. This standard was promulgated in accordance with procedures d
12、eveloped by the American National Standards Institute (ANSI). . Anti-siphon Fill Valves (Ballcocks) for Gravity Wafer Closet Flush Tanks 111 ASSE #lo02 Revised: 1999 Copyright American Society of Sanitary Engineering Provided by IHS under license with ASSE Licensee=University of Texas/5626000001 Not
13、 for Resale, 12/24/2006 00:23:05 MSTNo reproduction or networking permitted without license from IHS -,-,- 1? 1998-99 ASSE Product Standards Committee Richard J. Prospal Standards Committee Chairman Reliance Mechanical, Cleveland, Ohio Watts Regulator Company, North Andover, Massachusetts Canadian S
14、tandards, Etobicoke, Ontario, Canada State of Wisconsin DILHR, Madison, Wisconsin Delta Faucet Company, Indianapolis, Indiana ASSE Standards Coordinator, Westlake, Ohio Chicago Faucet Company, Des Plaines, Illinois Building Officials and Code Administrators, Inc., Country Club Hills, Illinois P. J.
15、Higgins 16.9 mm (0.625 in.) diameter minimum. NOTE: The shank bottom sur- face shall be smooth and flat. COUPLING NUT minimum Effective .Thread LOCKNUT (OR MOUNTING NUT) 38 (1.5 inch) Nominal Diameter 1.6 mm (0.0625 inch) Minimum Tolerance No Maximum Tolerance - I 7.87 mm (0.31 in.) minimum Tr - Not
16、e: Note: Thread lead-in chamber shall be permitted. 2.54 mm (0.1 inch) maximum lead in for thread shall be allowed. I. Instantly apply a constant vacuum of 63 mm ( 25 inches) of mercury for a period of one (1) minute during which, the sigth glass shall be inspected for indications of dye. 2. Apply v
17、acuums of 12,25,37,50, and 63 mm (5,l O, 1520, and 25 inches) of mercury and hold each for a period of one (1) minute, during which,the sight glass shall be inspected for indications of dye. 3.3.3 Criteria Backflow of water from the flush tank shall result in a rejection of the device. 3.4.1 Purpose
18、 The purpose of this test is to ensure that the device, when installed in a retrofit application, is capable of furnishing a minimum of 5.68 Umin (1.5 GPM) flow at 103.43 kPa (15 p.s.i.g.) flowing pressure. 3.4.2 Test Method Procedure The device shall be installed in a flush tank or a container. The
19、 device shall be set to run fully open and the flow rate measured by a volume-time or weight-time method. The flowing pressure shall be 55.2 kPa (8 p.s.i.g.), measured at the inlet to the valve. 3.4.3 Criteria Failure of the device to meet the requirements of Section 1.2.3.1.2 shall result in a reje
20、ction of the device. 6 Anti-siphon Fill Valves (Ballcocks) for Gravity Water Closet Flush Tanks ASSE #I002 Revised: 1999 Copyright American Society of Sanitary Engineering Provided by IHS under license with ASSE Licensee=University of Texas/5626000001 Not for Resale, 12/24/2006 00:23:05 MSTNo reprod
21、uction or networking permitted without license from IHS -,-,- 3.5.1 Purpose The purpose of the test is to ensure that the device, when installed in a retrofit application, is capable of delivering a minimum of 20% of total fill rate through the refill orifice at 103.43 kPa (15 p.s.i.g.) flowing pres
22、sure. 3.5.2 Test Method Procedure The device shall be installed in a flush tank ora container. The device shall be set to run fully open and the refill measured using a volume-time or weight-time method. The flowing pressure shall be 103.45 kPa (15 p.s.i.g.), measured at the inlet to the valve. 3.5.
23、3 Criteria Failure of the device to meet the requirements in Section 1.2.3.2 shall result in a rejection of the device. 3.6.1 Purpose This test shall be performed to determine the Critical Level (CL) marking of the device. Markings shall be placed on the unit as per Section 4.2.1. 3.6.2 Procedure Se
24、t up the device as per Section 3.3 with the check valve fouled as per Section 3.3.2.1. A “sight glass“ shall be assembled to the shank assembly as shown. With the tank water level lowered 3 mm (18 inch) below the vacuum breaker air port(s) or water discharge openings (air gaps type), the fill valve