ATS-5200.459-2004.pdf
《ATS-5200.459-2004.pdf》由会员分享,可在线阅读,更多相关《ATS-5200.459-2004.pdf(17页珍藏版)》请在三一文库上搜索。
1、ATS 5200.4592004 Australian Technical Specification Technical Specification for plumbing and drainage products Part 459: Waterless urinalsWall-hung ATS 5200.459 Accessed by TAFE QUEENSLAND INSTITUTES on 27 Dec 2007 This Australian Technical Specification was prepared by Committee WS-031, Technical P
2、rocedures for Plumbing and Drainage Products Certification. It was approved on behalf of the Council of Standards Australia on 26 September 2003 and published on 14 January 2004. The following are represented on Committee WS-031: AUSTAP Australian Industry Group Certification Bodies (Australia) Copp
3、er Development Centre, Australia Fire Contractors Federation Master Plumbers, Gasfitters and Drainlayers New Zealand New Zealand Water and Waste Association Plastics Industry Pipe Association of Australia Plumbing Industry Commission South Australian Water Corporation Water Services Association of A
4、ustralia Keeping Standards up-to-date Standards are living documents which reflect progress in science, technology and systems. To maintain their currency, all Standards are periodically reviewed, and new editions are published. Between editions, amendments may be issued. Standards may also be withd
5、rawn. It is important that readers assure themselves they are using a current Standard, which should include any amendments which may have been published since the Standard was purchased. Detailed information about Standards can be found by visiting the Standards Australia web site at .au and lookin
6、g up the relevant Standard in the on-line catalogue. Alternatively, the printed Catalogue provides information current at 1 January each year, and the monthly magazine, The Global Standard, has a full listing of revisions and amendments published each month. We also welcome suggestions for improveme
7、nt in our Standards, and especially encourage readers to notify us immediately of any apparent inaccuracies or ambiguities. Contact us via email at .au, or write to the Chief Executive, Standards Australia International Ltd, GPO Box 5420, Sydney, NSW 2001. Accessed by TAFE QUEENSLAND INSTITUTES on 2
8、7 Dec 2007 ATS 5200.4592004 Australian Technical Specification Technical Specification for plumbing and drainage products Part 459: Waterless urinalsWall-hung First published as ATS 5200.4592004. COPYRIGHT Standards Australia International All rights are reserved. No part of this work may be reprodu
9、ced or copied in any form or by any means, electronic or mechanical, including photocopying, without the written permission of the publisher. Published by Standards Australia International Ltd GPO Box 5420, Sydney, NSW 2001, Australia ISBN 0 7337 5565 8 Accessed by TAFE QUEENSLAND INSTITUTES on 27 D
10、ec 2007 ATS 5200.4592004 2 PREFACE This Technical Specification was prepared by the Joint Standards Australia/Standards New Zealand Committee WS-031, Technical Procedures for Plumbing and Drainage Products Certification. The objective of this Technical Specification is to enable product certificatio
11、n in accordance with the requirements of the Plumbing Code of Australia (PCA) and will continue until converted into an Australian Standard with the objective of converting within two (2) years of the approval date by the National Plumbing Regulatory Forum (NPRF). The word VOID set against a clause
12、indicates that the clause is not used in this Technical Specification. The inclusion of this word allows for the use of a common clause numbering system for the Plumbing and drainage, Technical Specifications. The test protocol and information in this Technical Specification was arranged by committe
13、e members to meet the authorization requirements given in the Plumbing Code of Australia. Accessed by TAFE QUEENSLAND INSTITUTES on 27 Dec 2007 3 ATS 5200.4592004 CONTENTS Page 1 SCOPE4 2 APPLICATION.4 3 REFERENCED DOCUMENTS4 4 DEFINITIONS4 5 MATERIALS4 6 MARKING5 7 VOID5 8 VOID5 9 PERFORMANCE REQUI
14、REMENTS AND METHODS 5 10 VOID5 11 PRODUCT DOCUMENTATION.5 APPENDIX A MEANS FOR DEMONSTRATING COMPLIANCE WITH THIS TECHNICAL SPECIFICATION7 Accessed by TAFE QUEENSLAND INSTITUTES on 27 Dec 2007 ATS 5200.4592004 4 Standards Australia .au STANDARDS AUSTRALIA Australian Technical Specification Technical
15、 Specification for plumbing and drainage products Part 459: Waterless urinalsWall-hung 1 SCOPE This Technical Specification sets out requirements for the WaterMark certification of waterless wall-hung urinals manufactured from vitreous china, plastic or stainless steel. 2 APPLICATION Appendix A sets
16、 out the means by which compliance with this Technical Specification can be demonstrated by a manufacturer for the purpose of product certification. 3 REFERENCED DOCUMENTS AS 1976 Vitreous china used in sanitary appliances AS/NZS 3500 Plumbing and drainage 3500.0 Part 0: Glossary of terms 3500.2 Par
17、t 2. Sanitary plumbing and drainage 3982 Urinals ANSI Z124.9 Plastic urinal fixtures ASTM A240/A240MChromium and chromium-nickel stainless steel plate, sheet and strip for pressure vessels and for general applications 4 DEFINITIONS For the purpose of this Standard, the definitions given in AS/NZS 35
18、00.0 apply. 5 MATERIALS 5.1 Vitreous china 5.1.1 Material Vitreous china shall comply with AS 1976. 5.1.2 Thickness The thickness at any point of the urinal shall be not less than 6 mm. 5.1.3 Surface finish All external surfaces, which are visible after installation, shall be glazed. Accessed by TAF
19、E QUEENSLAND INSTITUTES on 27 Dec 2007 5 ATS 5200.4592004 .au Standards Australia 5.2 Plastic Plastics shall comply with the requirements of ANSI Z124.91994. 5.3 Stainless steel Stainless steel shall be a minimum nominal thickness of 0.9 mm and comply with ASTM A240/A240M Grade 304 or 316 (see Secti
20、on 3 of AS/NZS 3982). 6 MARKING Waterless urinals shall be marked with the following: (a) Manufacturers name, brand or trademark. (b) WaterMark. (c) Licence number. (d) Batch identification (e) Model number. (f) The number of this Technical Specification, i.e., TS 5200.459. 7 VOID 8 VOID 9 PERFORMAN
21、CE REQUIREMENTS AND METHODS 9.1 Structural strength and integrity 9.1.1 Vitreous china and stainless steel Vitreous china and stainless steel shall comply with the requirements of AS 3982. 9.1.2 Plastics Plastics shall comply with the requirements ANSI Z124.9. 9.2 Sanitary performance Sanitary perfo
22、rmance shall be in accordance with ANSI Z124.9. 10 VOID 11 PRODUCT DOCUMENTATION 11.1 General Installation instructions shall be provided, which shall give full details of the installation procedure of the urinal, including the need for special tools or training. Care and maintenance instructions sh
23、all be provided and affixed to the urinal with the words May only be removed by occupant. 11.2 Installation instructions The installation instructions for waterless urinals shall include reference to installation in accordance with AS/NZS 3500.2. The instructions shall also draw attention to the req
24、uirement in AS/NZS 3500.2, that is Prior to installing a waterless wall-hung urinal to an existing system, the installer shall determine the materials of the pipes in the existing system. The undiluted discharge from a waterless urinal shall not be transported through copper or copper alloy pipework