1、Page 1 of 6 2007 ASHRAE. All rights reserved. ERRATA SHEET FOR THE FIRST PRINTING OF ANSI/ASHRAE/IESNA STANDARD 90.1-2004 (SI edition) Energy Standard for Buildings Except Low-Rise Residential Buildings May 1, 2007 The corrections listed in this errata sheet apply to the first printing of ANSI/ASHRA
2、E/IESNA Standard 90.1-2004, SI edition, identified as “86248 PC 1/05”on the outside back cover of the standard. Shaded items have been added since the previously published errata sheet dated March 23, 2007 was distributed. More than one errata sheet may be required for a specific document. Please re
3、view the entire list on the ASHRAE website related to the applicable document and download all that apply. NOTICE: ASHRAE now has a list server for Standing Standards Project Committee 90.1 (SSPC 90.1). Interested parties can now subscribe and unsubscribe to the list server and be automatically noti
4、fied via e-mail when activities and information related to the Standard and the Users Manual is available. To sign up for the list server please visit Project Committee List Servers for Standard on the Technology / Standards section of the ASHRAE website at http:/www.ashrae.org/publications/detail/1
5、5620. Page(s) Erratum 15 Section 3.3 Abbreviations and Acronyms. Change CTI from “Cooling Tower Institute” to “Cooling Technology Institute”. 17 Section 5. Building Envelope. In the compliance path figure at the beginning of Section 5 correct the spelling of prescriptive so it reads “5.5 Prescriptiv
6、e Path”. 19 Table 5.5.3.1. Change the title of Table 5.5.3.1 as follows: (Note: Additions are shown in underline and deletions are shown in strikethrough.) Roof U-Factor Multipliers for Exception to 5.5.1.1 5.5.3.1 22 through 30 TABLES 5.5-1 through 5.5-8 Building Envelope Requirements. Add a footno
7、te to the bottom of Tables 5.5-1 through 5.5-8 as follows: “The following definitions apply: ci = continuous insulation (see Section 3.2), NR = no (insulation) requirement.” 24 TABLE 5.5-3 Building Envelope Requirements for Climate Zone 3 (A, B, C). In footnote “b” of Table 5.5-3 change “non-residen
8、tial” to “nonresidential”. 34 P.O. Box 73383, Houston, TX 77273-3383 118 Table B-3 International Climate Zones. Inadvertent omission of the climate zones for New Zealand. Insert the following climate zone numbers as published in Addendum “am” to 90.1-2001: New Zealand Auckland Airport 4 Christchurch