《AS-NZS-60598.2.2-2001.pdf》由会员分享,可在线阅读,更多相关《AS-NZS-60598.2.2-2001.pdf(14页珍藏版)》请在三一文库上搜索。
1、AS/NZS 60598.2.2:2001 Australian/New Zealand Standard Luminaires Part 2.2: Particular requirements Recessed luminaires (IEC 60598-2-2:1996, MOD) AS/NZS 60598.2.2 Accessed by TAFE QUEENSLAND INSTITUTES on 23 Nov 2006 AS/NZS 60598.2.2:2001 This Joint Australian/New Zealand Standard was prepared by Joi
2、nt Technical Committee EL-041, Lamps and Related Equipment. It was approved on behalf of the Council of Standards Australia on 17 September 2001 and on behalf of the Council of Standards New Zealand on 12 October 2001. It was published on 29 November 2001. The following interests are represented on
3、Committee EL-041: Association of Consulting Engineers, Australia Australian Chamber of Commerce and Industry Australian Electrical and Electronic Manufacturers Association Consumers Federation of Australia Electrical Compliance Testing Association of Australia Energy Efficiency and Conservation Auth
4、ority of New Zealand Illuminating Engineering Society of Australia and New Zealand Ministry of Economic Development, New Zealand Electrical Regulatory Authorities Council (Australia) International Accreditation of NZ (IANZ) Keeping Standards up-to-date Standards are living documents which reflect pr
5、ogress in science, technology and systems. To maintain their currency, all Standards are periodically reviewed, and new editions are published. Between editions, amendments may be issued. Standards may also be withdrawn. It is important that readers assure themselves they are using a current Standar
6、d, which should include any amendments which may have been published since the Standard was purchased. Detailed information about joint Australian/New Zealand Standards can be found by visiting the Standards Australia web site at .au or Standards New Zealand web site at www.standards.co.nz and looki
7、ng up the relevant Standard in the on-line catalogue. Alternatively, both organizations publish an annual printed Catalogue with full details of all current Standards. For more frequent listings or notification of revisions, amendments and withdrawals, Standards Australia and Standards New Zealand o
8、ffer a number of update options. For information about these services, users should contact their respective national Standards organization. We also welcome suggestions for improvement in our Standards, and especially encourage readers to notify us immediately of any apparent inaccuracies or ambigu
9、ities. Please address your comments to the Chief Executive of either Standards Australia International or Standards New Zealand at the address shown on the back cover. This Standard was issued in draft form for comment as DR 01053. Accessed by TAFE QUEENSLAND INSTITUTES on 23 Nov 2006 AS/NZS 60598.2
10、.2:2001 Australian/New Zealand Standard Luminaires Part 2.2: Particular requirements Recessed luminaires (IEC 60598-2-2:1996, MOD) First published as AS/NZS 60598.2.2:2001 COPYRIGHT Standards Australia/Standards New Zealand All rights are reserved. No part of this work may be reproduced or copied in
11、 any form or by any means, electronic or mechanical, including photocopying, without the written permission of the publisher. Jointly published by Standards Australia International Ltd, GPO Box 5420, Sydney, NSW 2001 and Standards New Zealand, Private Bag 2439, Wellington 6020 ISBN 0 7337 4148 7 Acc
12、essed by TAFE QUEENSLAND INSTITUTES on 23 Nov 2006 ii PREFACE This Standard was prepared by Standards Australia/Standards New Zealand Committee, EL-041 Lamps and Related Equipment. The objective of this Standard is to provide manufacturers, users and regulators with electrical safety requirements fo
13、r recessed luminaires. This Standard is reproduced from IEC 60598-2-2:1996, Luminaires, Part 2: Particular requirementsSection 2: Recessed luminaires. It includes its Amendment 1:1997 and has been varied as indicated to take account of Australian/New Zealand conditions. Amendment 1:1997 to IEC 60598
14、-2-2 is incorporated in this document and identified by a marginal bar on the right hand side of the page. While this document is reproduced from IEC 60598.2.2 there are Australian and New Zealand variations in AS/NZS 60598.1:2001 to which this Standard refers for the majority of its requirements. T
15、hus an item complying with IEC 60598.2.2:1998 may not comply with AS/NZS 60598.2.2:2001. Australian and New Zealand variations to IEC 60598-2-2:1996 are indicated at the appropriate places throughout this Standard. Strikethrough (example) identifies IEC text, tables and figures which, for the purpos
16、es of this Australian/New Zealand Standard, are deleted. Where Australian/New Zealand text, tables or figures are added, each is set in its proper place and identified by shading (example). Added figures are not themselves shaded, but are identified by a shaded border. This Standard is a section of
17、Part 2 of a series dealing with luminaires. It is part of a series which, when complete, will consist of the following: AS/NZS 60598Luminaires Part 1:General requirements and tests Part 2.1:Particular requirementsFixed general purpose luminaires Part 2.2:Particular requirementsRecessed luminaires (t
18、his Standard) Part 2.3:Particular requirementsLuminaires for road and street lighting Part 2.4:Particular requirementsPortable general purpose luminaires Part 2.5:Particular requirementsFloodlights Part 2.6:Particular requirementsLuminaires with built-in transformers or convertors for filament lamps
19、 Part 2.8:Particular requirementsHandlamps Part 2.10:Particular requirementsPortable child-appealing luminaires Part 2.18:Particular requirementsLuminaires for swimming pools and similar applications Part 2.19:Particular requirementsAirhandling luminaires (safety requirements) Part 2.20:Particular r
20、equirementsLighting chains Part 2.23:Particular requirementsExtra low voltage lighting systems for filament lamps Part 2.25:Particular requirementsLuminaires for use in clinical areas of hospitals and health care buildings. Each Standard in Part 2 is intended to be used in conjunction with Part 1 in
21、 order to provide a complete Standard for that specific type of luminaire. Where a particular Clause of Part 1 is not mentioned in Part 2, that Clause applies as far as is reasonable. As this Standard is reproduced from an International Standard, the following applies: (a)Its number does not appear
22、on each page of text and its identity is shown only on the cover and title page. Accessed by TAFE QUEENSLAND INSTITUTES on 23 Nov 2006 iii (b)In the source text this International Standard should read this Standards Australia/Standards New Zealand Standard. The term informative has been used in this
23、 Standard to define the application of the annex to which it applies. An informative annex is only for information and guidance. Accessed by TAFE QUEENSLAND INSTITUTES on 23 Nov 2006 iv CONTENTS Page Section 2: Recessed luminaires Clause 2.1Scope 1 2.2General test requirements 1 2.3Definitions 1 2.4
24、Classification of luminaires 2 2.5Marking 2 2.6Construction 2 2.7Creepage distances and clearances. 2 2.8Provision for earthing. 2 2.9Terminals. 2 2.10External and internal wiring 3 2.11Protection against electric shock 3 2.12Endurance tests and thermal tests . 3 2.13Resistance to dust and moisture
25、4 2.14Insulation resistance and electric strength 4 2.15Resistance to heat, fire and tracking 4 Annex A - Measurement of ambient temperature in an installation (informative). 5 Accessed by TAFE QUEENSLAND INSTITUTES on 23 Nov 2006 COPYRIGHT 1 Standards Australia/Standards New Zealand Australian/New
26、Zealand Standard Luminaires Part 2.2: Particular requirementsRecessed luminaires (IEC 60598-2-2:1996, MOD) Any IEC table, figure or passage of text that is struck-through is not part of this Standard. Any Standards Australia/Standards New Zealand table, figure or passage of text that is added (and i
27、dentified by shading) is part of this Standard. 2.1Scope This section of IEC 60598-2 AS/NZS 60598.2 specifies requirements for recessed luminaires for use with tungsten filament, tubular fluorescent and other discharge lamps on supply voltage not exceeding 1 000 V. This section does not cover air-ha
28、ndling luminaires. This section does not apply to air-handling or liquid-cooled luminaires. 2.1.1Normative references The following normative documents contains provisions which, through reference in this text, constitute provisions of this section of IEC 60598-2 AS/NZS 60598.2. At the time of publi
29、cation, the editions indicated were valid. All normative documents are subject to revision, and parties to agreements based on this section of IEC 60598-2 AS/NZS 60598.2 are encouraged to investigate the possibility of applying the most recent editions of the normative document indicated below. Memb
30、ers of IEC and ISO maintain registers of currently valid International Standards. IEC 60227: Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V IEC 60245: Rubber insulated cables of rated voltages up to and including 450/750 V AS/NZS 60598.1, Luminaires General requi
31、rements and tests 2.2General test requirements The provisions of section 0 of IEC 60598-1 AS/NZS 60598.1 apply. The tests described in each appropriate section of part 1 shall be carried out in the order listed in this section of part 2. A procedure for measuring ambient temperature in an installati
32、on is given in annex A. 2.3Definitions For the purposes of this section, the definitions of section 1 of IEC 60598-1 AS/NZS 60598.1 apply. Accessed by TAFE QUEENSLAND INSTITUTES on 23 Nov 2006 COPYRIGHT 2 2.4Classification of luminaires Luminaires shall be classified in accordance with the provision
33、s of section 2 of IEC 60598-1 AS/NZS 60598.1. 2.5Marking The provisions of section 3 of IEC 60598-1 AS/NZS 60598.1 apply, together with the following additional markings requirements: 2.5.1Insulating ceiling F mark, symbol F Recessed luminaire suitable for mounting in normally flammable surfaces whe
34、re thermal insulating material may cover the luminaire. All recessed luminaires not marked with the symbol F shall have a warning notice on an attached label or given in the manufacturers instruction leaflet supplied with the luminaire, that the luminaire shall, under no circumstances, be covered wi
35、th insulating matting or similar material. 2.6Construction The provisions of section 4 of IEC 60598-1 AS/NZS 60598.1 apply except that for recessed parts the impact energy and spring compression required for the test specified in 4.13 of section 4 of IEC 60598-1 AS/NZS 60598.1 shall be as given in t
36、able 1 of this section. Table 1 Impact energy and spring compression Part to be testedImpact energy Nm Compression mm Parts (other than ceramic) providing protection against electric shock Ceramic parts and all other parts of the luminaires 0.35 0.20 17 13 2.7Creepage distances and clearances The pr
37、ovisions of section 11 of IEC 60598-1 AS/NZS 60598.1 apply. 2.8Provision for earthing The provisions of section 7 of IEC 60598-1 AS/NZS 60598.1 apply. 2.9Terminals The provisions of sections 14 and 15 of IEC 60598-1 AS/NZS 60598.1 apply. Accessed by TAFE QUEENSLAND INSTITUTES on 23 Nov 2006 COPYRIGH
38、T 3 2.10External and internal wiring The provisions of section 5 of IEC 60598-1 AS/NZS 60598.1 apply. Flexible cables or cords used as a means of connection to the supply, when supplied by the luminaire manufacturer, shall be at least equal in their mechanical and electrical properties to those spec
39、ified in IEC 60227*), IEC 60227A) or IEC 60245) and shall be capable of withstanding without deterioration the highest temperature to which they may be exposed under normal conditions of use. Materials other than p.v.c. and rubber are suitable if the above requirements are met, but in this instance
40、the particular specifications of chapter II of the above publications do not apply. Compliance shall be checked by the tests specified in 2.12. NOTE The use of flexible cables and cords with recessed luminaires is appropriate for the following reasons: 1)The flexible cable or cord cannot be easily t
41、ouched as it is out of reach within the recess. 2)To facilitate installation of the luminaire into the recess. 3)To permit the adjustment of adjustable recessed luminaires. 2.11Protection against electric shock The parts of the luminaire and components within the ceiling space or cavity shall provid
42、e the same degree of protection against electric shock as the luminaire parts below the ceiling space. NOTE The ceiling space or cavity is regarded as accessible for installation and maintenance, and the barriers do not provide adequate protection against electric shock. Compliance is checked by ins
43、pection. 2.12Endurance tests and thermal tests The provisions of section 12 of IEC 60598-1 AS/NZS 60598.1 apply together with the requirements of 2.12.1 and 2.12.2. 2.12.1Wiring, for connection to the supply, which passes into or can touch the luminaire shall not reach unsafe temperature. Compliance
44、 shall be checked by the following tests: The luminaire is connected to the supply using the cable provided with the luminaire or using a cable in accordance with the marking on the luminaire or, if not marked, as specified in the manufacturers instruction sheet; otherwise p.v.c. cable complying wit
45、h IEC 60227 is used. The hottest point is found (along the internal route or on the outer surface of the luminaire) with which the cable is likely to lie in contact during normal service. The cable is lightly held in contact at this point and the temperature of the insulation at the point of contact
46、 is measured as described in appendix F of IEC 60598-1 AS/NZS 60598.1. * ) Polyvinyl chloride insulated flexible cables and cords with circular conductors and a rated voltage not exceeding 750 V. ) First supplement: Single-core cable for internal wiring of household appliances. ) Rubber insulated fl
47、exible cables and cords with circular conductors and a rated voltage not exceeding 750 V. Accessed by TAFE QUEENSLAND INSTITUTES on 23 Nov 2006 COPYRIGHT 4 The operating temperature of the cable shall not exceed the limits given in table 2. Luminaires with an IP classification greater than IP20 shal
48、l be subjected to the relevant tests of clauses 12.4, 12.5 and 12.6 of section 12 of IEC 60598-1 AS/NZS 60598.1 after the test(s) of clause 9.2 but before the test(s) of clause 9.3 of section 9 of IEC 60598-1 AS/NZS 60598.1 specified in clause 2.13 of this section of IEC 60598-2. Table 2 Operating t
49、emperature of cable Designation of cableLimit of operating temperature Cable (including sleeves) provided with the luminaire Cable not provided with the luminaire: a) luminaires with cable temperature marking b) luminaires without cable temperature marking The maximum temperature specified in table XI of IEC 60598-1 AS/NZS 60598.1 The marked temperature The maximum temperature specified in table XI of IEC 60598-1 AS/NZS 60598.1 for ordinary PVC not subject to mechanical stress 2.13Resistance to dust and moisture The provisions of s