《BHMA-A156.29-2001.pdf》由会员分享,可在线阅读,更多相关《BHMA-A156.29-2001.pdf(12页珍藏版)》请在三一文库上搜索。
1、ANSIBHMA Al56.29-2001 AMERICAN NATIONALS TANDARD FOR EXIT LOCKS, EXIT LOCKS WITH EXIT ALARMS, EXIT ALARMS, ALARMS FOR EXIT DEVICES SPONSOR BUILDERS HARDWAREMANWACTUfPERS ASSOCIATION,INC. AMERICAN NATIONALSTANDARDS INSTITUTE, INC. Approved November 20.2001 Copyright Builders Hardware Manufacturers As
2、sociation Inc. Provided by IHS under license with BHMA Licensee=IHS Employees/1111111001, User=listmgr, listmgr Not for Resale, 03/06/2007 05:52:11 MSTNo reproduction or networking permitted without license from IHS -,-,- AMERICAN NATIONAL STANDARD An American National Standard implies a consensus o
3、f those substantially conrned with its scope and provisions. An American National Standard is intended as a guide to aid the manufacturer, the consumer and the general public. The existence of an American National Standard does not in any respect preclude anyone, whether he has approved the standard
4、 or not, frommanufacturmg, marketing purchasing or using products, processes, or procedures not conforming to the standard. Amencan National Standards are subject to periodic review andusers are cautioned to obtain the latest editions. CAUTION NOTICE: This Amencan National Standard is permitted to b
5、e revised or withdrawn at any time The procedures of theAmencan National Standards Institute require that action be taken to reaffirm, revise, or withdraw this standard no later than five years from the date of publication. Purchasers of Amencan National Standards receive current information on all
6、standards by calling or writing the Amencan National Standards Institute. Published by BUILDERS HARDWAREMANUFACTURERS ASSOCIATION, INC. www .buildershardware. com Copyright O2001 by the Builders Hardware M anufacturers Association, Inc. 355 Lexington Avenue New York, Nay York 10017 Not to be reprodu
7、ced without specific auhorization %om BHMA Printed in the USA Portions of this standard were first published as a part of A156.5 for Auxiliary for Auxiliary Locks ESD Immunity IEC 61000-4-2: 1995; RF Immunity IEC 61000-4-3:1995; EFT immunity IEC 61000-4-4:1995; ANSI/BHMA A156.18 2000, Materials and
8、Finishes. 5 Copyright Builders Hardware Manufacturers Association Inc. Provided by IHS under license with BHMA Licensee=IHS Employees/1111111001, User=listmgr, listmgr Not for Resale, 03/06/2007 05:52:11 MSTNo reproduction or networking permitted without license from IHS -,-,- 4 TEST METHODS No. of
9、Samples 4.1 Samples for testing shall be selected at random from the manufacturers finished stock and mounted in accordance with the manufacturers instructions. All hardware shall be installed in accordance with manufacturers standard installation instruction. For inside operational tests, an exit l
10、ock of the O1 function shall be used for qualification of a model. Any device within any one model having different working components or different materials shall be tested separately. Operational Tests Immunity Tests Finish Tests One per applicable Three Two per finish paragraph 6 Copyright Builde
11、rs Hardware Manufacturers Association Inc. Provided by IHS under license with BHMA Licensee=IHS Employees/1111111001, User=listmgr, listmgr Not for Resale, 03/06/2007 05:52:11 MSTNo reproduction or networking permitted without license from IHS -,-,- 5. OPERATIONAL TESTS 5.1 Applicability Table Produ
12、ct 5.2. 1 5.2.2 5.3.1 5.3.2 5.3.3 5.4 Normal exit test Cycle test Alarm cycle test Slam test Immunity test Exits with alarms Stand alone alarm X X (wall mounted) Stand alone alarm X X X (door mounted) Exit lock with alarm X X X X X Exit lock without X X alam Exit device with alarm X X X X 5.2 Tests
13、for Exit Locks 5.2.1 Normal Exit Test With the door latched, the actuating bar shall be depressed by a force not to exceed 151bf. (67N) until the latch clears the strike. The measurement shall be taken at the center of the actuating surface perpendicular to the door in the direction of swing but no
14、more than 16 inches from the latch edge of the door. The actuating surface shall be visually and physically distinct from the rest of the device. Portions of the actuating bar which are below 30 in. (762mm) and more than 44 in. (1 1OOmm) above the floor when installed per the manufacturers templatin
15、g are exempt from this requirement. Requirements 15 lbf max. (67N) 7 Copyright Builders Hardware Manufacturers Association Inc. Provided by IHS under license with BHMA Licensee=IHS Employees/1111111001, User=listmgr, listmgr Not for Resale, 03/06/2007 05:52:11 MSTNo reproduction or networking permit
16、ted without license from IHS -,-,- 5.2.2 Cycle Tests: Doors shall be opened by pushing on the actuating bar. The door shall be required to close and latch by the operation of the door closer except that in the case of a lock with a dead bolt which must be reset before the start of the next cycle. Ex
17、it locks shall complete the required number of cycles without failure or excessive wear that would impair operation. Dead latching if applicable shall be effective before and after the cycle test. Requirements: 100,000 cycles. At the completion of the test, the exit lock shall meet 5.2.1 and all ala
18、rm features shall function as intended. 5.3 Tests for Alarms 5.3.1 Cycle Tests for Alarms: Cycle the alarm 1,000 times. A cycle consists of actuating the alarm and resetting the alarm per the intended operation. If battery powered, the batteries are permitted to be replaced durmg the test as require
19、d. Requirements: Allthealam features shall function as intended at the end of 1,000 cycles. 5.3.2 Slam Test: With the alarm mounted on the slam test door fixture, adjust to provide no latching or locking engagement. Use a size 3 overhead door closer with standard arm mounting and ail valves fully op
20、en. Door closing speed shall be 2.5 seconds or less from 90 degrees open to fully closed with no deceleration during the closing cycle. Requirements: 1,000 cycles. This test does not apply to alarms mounted on the wall. All the alarm features shall function as intended at the completion of the test.
21、 5.3.3 Immunity Compliance. Exit Locks with Alarms, and Alarms for Exit Devices shall meet the requirements noted below for ESD immunity and RF immunity. Products which are capable of being powered by the AC mains are required to be tested for EFT Immunity. The alarm shall function as intended at th
22、e completion of the tests. Requirements: ESD - Requirements of level 4 of IEC 61000-4-2 shall be met. RF Immunity - Requirements of level 2 of IEC 61000-4-3 shall be met. EFT Immunity - Requirements of level 2 of IEC 61000-4-4 shall be met. 5.4 Tests for Exit Devices with Alarms. In addition to meet
23、ing the requirements of 5.3, exit devices with alarms shall be subjected to the A156.3, Exit Devices, cycles for the appropriate grade, and the alarm shall function as intended upon completion of the cycles. 8 Copyright Builders Hardware Manufacturers Association Inc. Provided by IHS under license w
24、ith BHMA Licensee=IHS Employees/1111111001, User=listmgr, listmgr Not for Resale, 03/06/2007 05:52:11 MSTNo reproduction or networking permitted without license from IHS -,-,- 6. FINISH TESTS 6.1 These requirements do not predict the performance life of the finishes in actual use but are used as a q
25、uality control method to ensure consistent finish quality. All exposed, architecturally finished parts are subject to the finish requirements as detailed below. The values given are minimum requirements. All tests shall be conducted in accordance with the applicable section of ANSUBHMA A156.18-2000.
26、 Finish tests are for all grades. 6.2 Salt Spray Test Requirements. Organic coatings except lock fronts and stand alone exit alarms: Organic coatings on fronts and stand alone exit alarms: Inorganic coatings or base materials: 96 Hours 24 Hours 200 Hours 6.3 Humidity Test Requirements. Applicable fo
27、r Organic Coatings only. Fronts and stand alone exit alarms: All other parts: 240 Hours Pencil Hardness: 2H; Adhesion: Classification 4 Method B 48 Hours 6.4 Hardness Test Requirements. Conduct either 6.4.1 or 6.4.2 at the option of the manufacturer. Applicable for Organic Coatings only 6.4.1 Pencil
28、 Hardness Test Requirements. Fronts and stand alone exit alarms: 2H; All other parts: 3H 6.4.2 Taber Abrasion Resistance Test Requirements: 500 cycles. 6.5 Perspiration Test Requirements. Applicable for organic coatings only. Test does not apply to Stand Alone Exit Alarms. 4 Cycles; Pencil Hardness
29、2B 6.6 Ultraviolet Light and Condensation Test Requirements. Applicable for organic coatings only. Test cycle 8 hours U.V. and 4 hours humidity at 50 degrees C for 144 total hours; Test to exterior grade using UVA 340 lamps. 9 Copyright Builders Hardware Manufacturers Association Inc. Provided by IH
30、S under license with BHMA Licensee=IHS Employees/1111111001, User=listmgr, listmgr Not for Resale, 03/06/2007 05:52:11 MSTNo reproduction or networking permitted without license from IHS -,-,- 7. DESCRIPTION AND TYPE NUMBERS Description and Type Numbers of Exit Locks and Alarms 7.1 Typical Exit Alam
31、 Typical Exit Lock 7.1.1 Exit Alarm E041 1: Armed and disarmed by an inside control key. Allows authorized entry or exit by means of an on and off key switch or electronic circuitry. When armed, unauthorized use activates powered sounding device. If specified it shall 1) be connected to a remote ind
32、icating panel, or 2) be mounted separate from the door and activated by a door movement switch, or 3) be furnished with an outside control key, or 4) rearm automatically after authorized use. 7.1.2 Exit Lock E0421: For out swinging single doors. Surface applied. Activated by arm, push plate or paddl
33、e. Outside key control furnished when specified. Includes powered sounding device when set by inside key, sounds when door is opened. Has dead bolt or latch bolt with either surface or mortise strike. Furnished with a silent alarm indicated at remote panel in a low voltage system if specified. 7.1.3
34、 Exit Lock E0441 : For pairs of doors. Mounted with top and bottom bolt assembly and overlapping brackets to hold the inactive leaf locked until active leaf is opened by pressure on arm, push plate or paddle. Opening the active leaf opens both leaves. Otherwise same as E0421. 7.1.4 Exit Lock E0461 :
35、 For pairs of doors. Inactive leaf to have top and bottom bolt assembly activated by arm, push plate or paddle. Active leaf to have E0421 exit lock. Active leaf opens first. Inactive leaf remains secure until active leaf is released. Otherwise the same as E042 1. 7.1.5 Exit LockE0481: Forpain of doo
36、rs. Both leaves to have top and bottom bolt assanbly activated by arm,pushplate , or paddle. Eachleafopens independently. Otherwise sameas E0421. 8. EXPLANATION OF IDENTIFYING NUMBERS 8.1 First letter denotes BHMA Product section (E) 8.2 First numeral indicates general or t r i m material used: 10 C
37、opyright Builders Hardware Manufacturers Association Inc. Provided by IHS under license with BHMA Licensee=IHS Employees/1111111001, User=listmgr, listmgr Not for Resale, 03/06/2007 05:52:11 MSTNo reproduction or networking permitted without license from IHS -,-,- O - Optional material 1 - Cast, for
38、ged or extruded brass or bronze 2 - Wrought brass or bronze 3 - Cast, forged or extruded aluminum 4 - Wrought aluminum 5 - Stainless steel, 300 series 6 - Malleable iron 7 - Cast iron 8 -Wrought steel 9 - Zinc alloys 8.2.1 In this Standard, the first numeral O (optional material) has been used. Spec
39、ifiers who delineate a specific trim material do so by substituting the first numeral O as appropriate. Manufacturers catalogs are consulted to confirm availability. Trim materials most commonly used are aluminum, brass, bronze, 300 series stainless steel and zinc alloy. 8.3 Locks are identified by
40、the numeral “4“. The second numeral for the products covered identifies the type of product. Exit Alarms and Exit 8.4 Example: E0411 E - Section - (E) O Material (Optional) 4 - Type of Product (Exit Lock) 1 - Function 1 - Grade (Grade 1) 11 Copyright Builders Hardware Manufacturers Association Inc.
41、Provided by IHS under license with BHMA Licensee=IHS Employees/1111111001, User=listmgr, listmgr Not for Resale, 03/06/2007 05:52:11 MSTNo reproduction or networking permitted without license from IHS -,-,- APPENDIX A USERS GUIDE (Not a part of ANSUBHMA Al 56.29) A-1 DOORS AND FRAMES The provisions
42、of this Standard evaluate locks as a component and do not take under consideration the variety of doors, frames and other components available, some of which are vulnerable under the kinds of attacks described. Select doors, frames and surrounding wall systems compatible with the level of lock secur
43、ity selected. A-2 FASTENERS Where lock strikes are applied to wood frames under 1 inch (25.4 mm) thick, screws normally furnished are sometimes inadequate. Specifi screws of sufficient length to engage the structural stud behind the frame. A-3 FINISHES See ANSI/BHMA Standard Al 56.18-2000 for Materi
44、als and Finishes for a description of the finishes. Other available finishes are found in individual manufacturers catalogs. A-4 CONFORMANCE CRITERIA Certification that products offered meet the requirements of this Standard and conform to individual manufacturers drawings, specifications, standards
45、 and quality assurance practices are available and in some circumstances are required. Buyer requirements determine the need for proof of conformance such as first article inspection, test laboratory reports, or listings. Specifiers requiring assertions of conformance utilize statements of conforman
46、ce by individual manufacturers, or test reports acceptable to the buyer. A-5 PRESERVATION, PACKAGING AND PACKING Unless other arrangements between buyer and seller are made, preservation, packaging and packing shall be sufficient to protect containers and their contents under normal shipping and han
47、dling conditions fi-om the source of supply to the destination point. A-6 MARKING Unless other arrangements between buyer and seller are made, marking shall be in accordance with the individual manufacturers standard practice. 12 Copyright Builders Hardware Manufacturers Association Inc. Provided by IHS under license with BHMA Licensee=IHS Employees/1111111001, User=listmgr, listmgr Not for Resale, 03/06/2007 05:52:11 MSTNo reproduction or networking permitted without license from IHS -,-,-