1、ANSI/BHMA A156.17-2004 Revision of: ANSI/BHMA A156.17-1999 AMERICAN NATIONAL STANDARD FOR SELF CLOSING HINGES the qualifying lateral measurement is the average of these two. For pivots, measure and record the vertical relationship between the top of the door and the adjacent header or reference poin
2、t at the pivot axis with the door closed. Measure and record the lateral relationship of the door with the jamb at the top pivot point. 5.2 For hinges or pivots with adjustable spring force, adjust to provide a total closing force equal to or greater than the minimum given for the hinges or pivots i
3、n 5.2.1. The manufacturers recommended adjustment procedures shall be used. For non-adjustable spring hinges or pivots, the closing force shall equal or exceed the minimum values shown in 5.2.1. (See 6.1) 5.2.1 Closing Force Requirements - Minimum Single Acting Hinges Flange Height Test Door Weight
4、Test Door Width Closing Force in (mm)lbs (kg)in (mm)lbf (N) 3 (76) 60 (27)30 (762).50 (2.2) 3.5 (89) 80 (36)30 (762).75 (3.3) 4 (102) 100(45)36 (914) 1.00 (4.4) 4.5 (114) 120(54)36 (914) 1.25 (5.5) 5 (127) 120(54)36 (914) 1.25 (5.5) 6 (152) 140(63)36 (914) 3.00 (13) 7 (178) 160(73) 48 (1219) 4.00 (1
5、8) -,-,- 8 Double Acting Hinges Flange Height* Test Door Weight Test Door Width Closing Force in (mm)lbs (kg)in (mm)lbf (N) 2 (51) 18 (8) 18 (457) .25 (1.1) 3 (76) 35 (16)30 (762) .50 (2.2) 4 (102)75 (34)36 (914) 1.50 (6.6) 5 (127)90 (41)36 (914) 2.50 (11) 6 (152) 100(45)36 (914) 3.50 (16) 7 (178) 1
6、20(55)42 (1067) 4.50 (20) 8 (203) 140(64)48 (1219) 5.50 (24) HD 320 (145)48 (1219) 8.00 (35) (HD = Heavy Duty Category) *Measured at the knuckle or pivot point Pivots Test Door Weight Test Door Width Closing Force Category lbs (kg)in (mm)lbf (N) A 18 ( 8) 18 (457) .25 (1.1) B 35 (16)30 (762) .50 (2.
7、2) C 75 (34)36 (914) 1.50 (6.7) D 100(45)36 (914) 2.00 (8.8) 5.3 Start the cycle test (see 6.2.2). After 4,000 cycles stop test and measure closing force as described in 6.1. Closing force shall equal or exceed the value given in 5.2.1. Resume the cycle test and complete the required number of cycle
8、s given in 5.3.1. 5.3.1 Cycle Requirements Single Acting Hinges Double Acting Hinges & Pivots *Cycles Number Number Grade 1 1,000,000 500,000 Grade 2 500,000 250,000 Grade 3 250,000 100,000 *Numbers of cycles pertain to the specific conditions and degrees of wear outlined in this test procedure and
9、are not recommendations to guide selection for actual installations. 5.4 At the conclusion of the cycle test, remeasure closing force as described in 6.1. Closing force shall equal or exceed the value given in 5.2.1. 9 5.5 At the conclusion of the cycle test, measure vertical and lateral relationshi
10、ps as described in 5.1. Changes in measurement for any one hinge for vertical measurement shall not exceed the values given in 5.5.1. 5.5.1 Vertical and Lateral Wear Requirements Vertical Relationship inches (mm) Grade 1 0.020 (0.52) Grade 2 0.030 (0.79) Grade 3 0.060 (1.50) Lateral Change and Defor
11、mation All Grades 0.062 (1.60) 5.6 Conduct the latch test if applicable. (See 6.3) 5.7 Conduct lateral change and deformation static load test. (See 6.4) 5.8 If any hinge springs break during an initial test, the test shall be stopped and new hinges shall be installed and the test shall be started o
12、ver. If in the second test any hinge springs break, the hinges shall have failed the test. 5.9 Conduct finish tests (6.5). 6. TEST DETAILS 6.1 Closing Force Test 6.1.1 Prior to the start of the cycle test 6.2, draw a line on the floor parallel to the door in the 45 degree + 2 degrees open position.
13、6.1.2 Conduct the closing force test at the beginning of the cycle test. Test: Open the door to the 45 degree mark on the floor, and position the force gage to contact the door at 30 inches (762 mm) from the pivot axis. 6.1.3 In the case of spring hinges, the manufacturer shall elect to achieve the
14、required closing force with a minimum of two or all three of the hinges being tested and shall clearly indicate the number of hinges required to be tensioned to meet the value specified. 6.2 Cycle Test 6.2.1 Mount hinges or pivots in accordance with 4.1 and 4.2 and set closing force of adjustable hi
15、nges or pivots in accordance with 5.2. 6.2.2 Mechanically open the door to 90 degrees + 5 degrees and release, allowing the hinges or pivots to completely close the door within 5 degrees of the normal closed position. One opening and closing constitutes one cycle. Repeat for the required number of c
16、ycles as given in 5.3.1. Cycles per minute shall be a maximum of 20. 6.2.3 Double acting hinges or pivots shall be cycled in each direction. Alternately cycling the test door in one direction and then the other for the required number of cycles shall be permitted. Cycling the door for 25,000 times i
17、n one direction and then 25,000 times in the other for the required number of cycles given in 5.3.1 shall be permitted. One opening and closing in each direction constitutes two cycles. 10 6.2.4 At the conclusion of the cycle test (6.2), remeasure and record vertical and lateral relationship of all
18、hinges or pivots in 5.1. All measurements shall be taken at the same door position as initial measurements made at the start of the test. 6.3 Latch Test for Single Acting Doors 6.3.1 After the remeasurement in 6.2.4, release the door from 45 degrees open and measure the impact of the door at the 5 d
19、egree open position. The impact shall not be less than a 4.5 lbf (20 N) at a point where a latch is located. (See 4.3.2) 6.4 Static Load Test 6.4.1 Lateral change and deformation. At the conclusion of the latch test 6.3 and with the door in the 0 degree (closed) position, add and remove 150 lbs. (68
20、 kg) at a point on the door at a horizontal distance from the pivot axis equal to the test door width shown in 5.2.1. Lateral shift of the door leaf away from the jamb at top hinge shall not exceed .062 in (1.6 mm). Exception: Double acting spring hinges and pivots are not subject to this test. 6.5
21、Finish Tests 6.5.1 Salt Spray Test. This test shall be conducted in accordance with ANSI/BHMA A156.18-2000 for Materials and Finishes. 6.5.1.1 Salt Spray Test Requirements Hour Requirements For All Grades Finish Type Hours Clear coatings on multiple plated ferrous material 24 Clear coatings on singl
22、e plated ferrous material 18 Ferrous plated material without clear coatings 24 Non-ferrous material plated or unplated, coated or uncoated 72 Stainless steel 200 Painted material 48 6.5.2 Test Parts. The parts for testing shall be selected at random and shall be three pieces. When one part is notice