1、ISBN 0 7337 7271 4 AS/NZS 3823.1.1/Amdt 3/2006-02-24 STANDARDS AUSTRALIA/STANDARDS NEW ZEALAND Amendment No. 3 to AS/NZS 3823.1.1:1998 Performance of electrical appliancesAirconditioners and heat pumps Part 1.1: Non-ducted air conditioners and heat pumpsTesting and rating of performance REVISED TEXT
2、 The 1998 edition of AS/NZS 3823.1.1 is amended as follows; the amendments should be inserted in the appropriate places. SUMMARY: This Amendment applies to the Preface and Appendix ZZ. Published on 24 February 2006. Approved for publication in New Zealand on behalf of the Standards Council of New Ze
3、aland on 21 December 2005. Preface Add the following references after AS/NZS 1677.1: AS/NZS 3823 Performance of electrical appliancesAirconditioners and heat pumps 3823.1.3 Part 1.3: Water-source heat pumpsWater-to-air and brine-to-air heat pumpsTesting and rating of performance 62301 Household elec
4、trical appliancesMeasurement of standby power Clause 1.1 Delete Clause 1.1 as amended by Amendment No. 2 2002 and replace with the following: This Standard specifies the conditions on which the capacity and energy consumption of factory-made residential, commercial and industrial electrically driven
5、, mechanical- compression, single-package and split-system non-ducted airconditioners employing air-cooled condensers and non-ducted air-to-air heat pumps are based. The Standard also specifies the test methods to be applied for determining the capacity and efficiency ratings. This Standard covers e
6、quipment utilizing one or more refrigeration systems with one outdoor unit and one or more indoor units controlled by a single thermostat/controller. This Standard covers equipment utilizing single, multiple and variable capacity components. NOTE: Air conditioners with water cooled condensers have b
7、een excluded from this part and are now covered under the requirements of AS/NZS 3823.1.3. Clause 1.3 Add the following sentence: (e) individual evaporator/condenser assemblies for separate use. AMDT No. 3 FEB 2006 AMDT No. 3 FEB 2006 AMDT No. 3 FEB 2006 Accessed by TAFE QUEENSLAND INSTITUTES on 22
8、Nov 2007 Clause 1.7 Delete Clause 1.7 and replace with the following: This Standard does not cover the determination of seasonal efficiencies which may be required in some countries. Table 5 Delete High and insert H1, delete low and insert H2, delete extra low and insert H3. Clause 6.5 and 6.6 Add n
9、ew Clauses 6.5 Standby power and crank case heaters Measurements of standby power and crank case heater power shall be undertaken in accordance with the procedures and instruments specified in AS/NZS 62301 and shall be determined for the following modes (as applicable) on the airconditioner: (a) Off
10、 mode (where applicable). (b) Passive standby mode (where applicable). (c) Delay start mode (where applicable). (d) Average crank case heater power for various outdoor conditions. Power in each applicable mode shall be reported in Watts to the nearest 0.1 W or better. 6.5.1 Off mode Where the air co
11、nditioner is not operational and where the air conditioner has no remote control or automatic program functions or these are inoperative. This mode is the lowest power consumption mode that cannot be switched off (influenced) by the user and that persists for an indefinite time when an appliance is