《BS-7352-1990.pdf》由会员分享,可在线阅读,更多相关《BS-7352-1990.pdf(22页珍藏版)》请在三一文库上搜索。
1、BRITISH STANDARD BS 7352:1990 Specification for Strength and durability performance of metal hinges for side hanging applications and dimensional requirements for template drilled hinges Licensed Copy: London South Bank University, London South Bank University, Fri Dec 08 11:24:55 GMT+00:00 2006, Un
2、controlled Copy, (c) BSI BS 7352:1990 This British Standard, having been prepared under the direction of the Elements and Components (of Diverse Materials) for Buildings Standards Policy Committee, was published under the authority of the Board of BSI and comes into effect on 31 October 1990 BSI 03-
3、1999 First published as BS 1227-1 A, May 1945 Second edition, March 1967 Third edition as BS 7352 October 1990 The following BSI references relate to the work on this standard: Committee reference ECB/41 Draft for comment 89/12615 DC ISBN 0 580 18857 4 Committees responsible for this British Standar
4、d The preparation of this British Standard was entrusted by the Elements and Components (of Diverse Materials) for Buildings Standards Policy Committee (ECB/-) to Technical Committee ECB/41, upon which the following bodies were represented: Aluminium Window Association Association of Builders Hardwa
5、re Manufacturers Association of Burglary Insurance Surveyors British Hardware Federation British Lock Manufacturers Association British Plastics Federation British Woodworking Federation Consumer Policy Committee of BSI Department of Health Department of the Environment (Building Research Establishm
6、ent) Department of the Environment (Property Services Agency) Glass and Glazing Federation Guild of Architectural Ironmongers Incorporated Association of Architects and Surveyors Institute of Architectural Ironmongers Institute of Carpenters Loss Prevention Council Royal Institute of British Archite
7、cts The following body was also represented in the drafting of the standard, through subcommittees and panels: Steel Hingemakers Association Amendments issued since publication Amd. No.DateComments Licensed Copy: London South Bank University, London South Bank University, Fri Dec 08 11:24:55 GMT+00:
8、00 2006, Uncontrolled Copy, (c) BSI BS 7352:1990 BSI 03-1999i Contents Page Committees responsible Inside front cover Foreword ii 1Scope1 2Definitions1 3Classification1 4Tests1 5Test loads, numbers of cycles and acceptance criteria2 6Corrosion protection3 7Template drilled hinges3 8Marking4 Appendix
9、 A Test apparatus7 Appendix B Test procedures8 Appendix C Guidance for the selection and use of hinges10 Figure 1 Limits of allowable deformation in static load tests2 Figure 2 Limits of allowable wear in endurance test3 Figure 3 Full mortice template hinge, 76.2 mm (3 in) size (A30M)5 Figure 4 Full
10、 mortice template hinge, 88.9 mm (3.5 in) size (A35M)5 Figure 5 Full mortice template hinge, 101.6 mm (4 in), 114.3 mm (4.5 in) and 127.0 mm (5 in) sizes (A40M, A45M, A50M)6 Figure 6 Full mortice template hinge, 152.4 mm (6 in) size (A60M)6 Figure 7 Typical arrangement for a hinge endurance test rig
11、7 Figure 8 Details of hinge mounting position8 Figure 9 Positions of datum surfaces8 Table 1 Classification of hinges1 Table 2 Static load tests2 Table 3 Endurance test3 Table 4 Corrosion protection classification3 Table 5 Mass ranges of typical doors11 Table 6 Typical masses of single glazed vents,
12、 glass thickness 4 mm11 Table 7 Typical masses of double glazed vents, glass thicknesses 4 mm + 4 mm11 Table 8 Typical masses of single glazed vents, glass thickness 6 mm11 Table 9 Typical masses of double glazed vents, glass thicknesses 6 mm + 6 mm11 Table 10 Estimated frequency of operation of doo
13、rs12 Table 11 Reduction in maximum leaf weight for wide doors13 Publications referred to Inside back cover Licensed Copy: London South Bank University, London South Bank University, Fri Dec 08 11:24:55 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 7352:1990 ii BSI 03-1999 Foreword This British Stand
14、ard has been prepared under the direction of the Elements and Components (of Diverse Materials) for Buildings Standards Policy Commitee. It supersedes BS 1227-1A:1967, which is withdrawn. BS 1227-1A was first published in 1945 and revised in 1967. The standard specified minimum requirements for the
15、materials, workmanship, construction, dimensions and weights of knuckle type hinges made of steel, cast iron, solid drawn (extruded) brass and aluminium, and band type hinges made of steel. It did not include any performance requirements for strength, mechanical endurance or durability of finish. Th
16、e dimensional requirements have proved insufficient to ensure complete interchangeability between nominally similar hinges made by different manufacturers. There is an increasing number of applications where door closers are fitted to heavy doors (often fire doors) in public, institutional and comme
17、rcial buildings, and experience has shown that problems can arise in service if the hinges for such heavy doors are not correctly selected and fitted. BS 7352 covers nine classes of hinges suitable for side hanging applications ranging from lightweight cupboard doors weighing under 10 kg to leaves w
18、eighing up to 120 kg. The standard specifies static strength test requirements and allowable wear during endurance testing for all hinges, and corrosion protection requirements for those hinges which are not intended to be painted after fitting. It specifies the maximum level of frictional resistanc
19、e generated by hinges, and the maximum initial free movement permitted between components. It also includes dimensional requirements for full mortice template drilled hinges for use on metal doors and frames. These follow American practice, which is widely accepted internationally. There are special
20、 requirements which are not covered by this standard for hinges for some types of windows. Because the performance characteristics of plastics materials are liable to change significantly with age this standard does not cover hinges whose principal components are made from such materials. Appendices
21、 give details of a suitable test rig (Appendix A), test procedures (Appendix B) and guidance on the selection and use of hinges (including hinges for unusually large doors and for fire door applications)(Appendix C). A British Standard does not purport to include all the necessary provisions of a co
22、ntract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, pages 1 to 16, an inside back
23、 cover and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover. Licensed Copy: London South Bank University, London South Bank University, Fri Dec 08 11:24:55 GMT+00:00 200
24、6, Uncontrolled Copy, (c) BSI BS 7352:1990 BSI 03-19991 1 Scope This British Standard specifies static strength testing and allowable wear during endurance testing for all single axis metal hinges for side hanging applications for leaves weighing up to 120 kg and leaf dimensions up to 2 400 mm high
25、by 1 200 mm wide. It also specifies corrosion protection for those metal hinges which are not intended to be painted after fitting. It specifies the maximum permissible torque arising from frictional resistance generated within the hinge during endurance testing, the maximum amount of initial horizo
26、ntal movement permitted between components for all hinges and the maximum amount of initial vertical movement between components for hinges other than lift off types. It also specifies dimensional and other requirements for full mortice template drilled hinges for metal doors and frames. The metals
27、used for the principal components of hinges such as leaves, knuckles, barrels and pins may be ferrous or non-ferrous without restriction on the methods of fabrication. The use of plastics materials for such components is excluded, but plastics or other non-metallic materials may be used for ancillar
28、y components such as washers, bushes or ferrules, or for the corrosion protection of metal components. Where compliance with BS 7352 is claimed for turn-tilt window hinges, the test requirements apply to the side hung (turn) mode only. The standard does not specify multiple axis variable geometry fr
29、iction hinges for windows nor hinges incorporating spring assisted closing mechanisms. The fastenings used to fix hinges to leaves and to structures are not specified by this standard. Accordingly, hinges under test are bolted to the test rig. NOTE 1This standard does not include specific additional
30、 requirements for hinges for fire doors but general guidance on fire door applications is given in C.11. NOTE 2The titles of the publications referred to in this standard are listed on the inside back cover. 2 Definitions For the purposes of this British Standard, the following definitions apply. 2.
31、1 significant surface any surface which is visible when the hinge is installed and which is essential to the appearance, function or serviceability of the hinge 2.2 full mortice template drilled hinge a hinge designed for morticing into the butt edge of the door and into the rebate edge of the frame
32、 NOTEThese hinges are used generally with steel frames and steel doors. 3 Classification Hinges are classified according to the maximum mass of the hinged leaf with which they will be used and the maximum annual number of operations as given in Table 1. Table 1 Classification of hinges 4 Tests 4.1 A
33、mbient temperature The temperature in the laboratory shall be maintained at 20 5 C throughout the period of testing. 4.2 Static load tests One hinge of each type shall be subjected to the initial measurement tests described in B.1 and to both of the static load tests described in B.2 in succession.
34、4.3 Endurance test One hinge of each type shall be subjected to the test described in B.3. This hinge shall not previously have been subjected to the static load tests specified in 4.2. It shall be tested as supplied without additional lubrication, except that for endurance tests of 200 000 or 500 0
35、00 cycles the hinge shall be lubricated in accordance with B.3. ClassMaximum mass of hinged leaf Maximum annual number of operations kgcycles 1 2 3 4 5 6 7 8 9 10 20 20 40 40 40 60 80 120 5 000 5 000 25 000 25 000 200 000 500 000 500 000 200 000 200 000 NOTEThese nine classes cover the majority of a
36、pplications (see C.4 to C.6). The masses are based on the use of three hinges per leaf. If two hinges are used the masses listed should be reduced by one third. (See also C.7.) Licensed Copy: London South Bank University, London South Bank University, Fri Dec 08 11:24:55 GMT+00:00 2006, Uncontrolled
37、 Copy, (c) BSI BS 7352:1990 2 BSI 03-1999 4.4 Corrosion test When applicable, one hinge of each type shall be subjected to the corrosion test specified in clause 6. This hinge shall not previously have been subjected to any other tests. 5 Test loads, numbers of cycles and acceptance criteria 5.1 Ini
38、tial measurements When tested in accordance with B.1 the maximum permissible initial horizontal free movement shall be 0.2 mm and the maximum permissible initial vertical free movement shall be 0.4 mm. 5.2 Static load tests 5.2.1 Maximum load The maximum prescribed load for each class shall be as gi
39、ven in Table 2. Table 2 Static load tests 5.2.2 Acceptance criteria 5.2.2.1 Load-deformation test When tested in accordance with B.2.1 the hinge shall comply with the following: a) the maximum lateral displacement under load shall be 2 mm; b) the maximum vertical displacement under load shall be 4 m
40、m; c) the lateral and vertical residual displacements after unloading shall be within the shaded area of Figure 1; d) there shall be no visible cracking or breakage of any component. 5.2.2.2 Overload test When tested in accordance with B.2.2, the hinge shall comply with the following: a) there shall
41、 be no breakage of any hinge leaf, knuckle, barrel or pin; b) the test leaf shall remain connected to the frame even though the hinge may have been rendered inoperable. 5.3 Endurance test 5.3.1 Mass of test leaf and number of cycles The mass of the test leaf and number of cycles for each class shall
42、 be as given in Table 3. Figure 1 Limits of allowable deformation in static load tests ClassLoad-deformation test maximum test load (see note) Overload test (see note) kgkg 1 2 3 4 5 6 7 8 9 20 40 40 80 80 80 120 160 240 30 60 60 120 120 120 180 240 360 NOTEThe test loads have a tolerance of + 0.5,
43、0 kg Licensed Copy: London South Bank University, London South Bank University, Fri Dec 08 11:24:55 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 7352:1990 BSI 03-19993 Table 3 Endurance test 5.3.2 Acceptance criteria 5.3.2.1 When tested in accordance with B.3 the amounts of lateral and vertical wea
44、r of the hinge tested measured as displacements of the datum surfaces shall be within the shaded area of Figure 2. 5.3.2.2 When tested in accordance with B.3, the maximum permissible frictional torque measured at 4 000 cycles and at the end of the test shall be 2 Nm for classes 1 to 6, 3 Nm for clas
45、ses 7 and 8 and 4 Nm for class 9. 5.4 Retesting 5.4.1 Static load tests If the hinge tested fails to comply with any one of the acceptance criteria then a further sample of two hinges shall be subjected to the test in which failure occurred. If both hinges retested then comply with the acceptance cr
46、iteria, the first failure shall be ignored. If either of the hinges retested fails to comply with all of the acceptance criteria no further retesting shall be allowed. 5.4.2 Endurance test If the hinge tested fails to comply with the acceptance criteria then a further sample of two hinges shall be s
47、ubjected to the endurance test. If both hinges then comply with the acceptance criteria the first failure shall be ignored. If either of the hinges retested fails to comply with the acceptance criteria no further retesting shall be allowed. 6 Corrosion protection NOTE 1Hinges which are supplied in s
48、elf colour mill finish for subsequent corrosion protection in situ, e.g. by painting, are not subject to the requirements of this clause. Hinges shall be subjected to neutral salt spray testing in accordance with BS 5466-1. The hinges shall be examined after each of the exposure periods specified in
49、 Table 4 until corrosion of the base metal on significant surfaces is visible to the unaided eye. NOTE 2Staining or discoloration of an applied surface treatment is acceptable and should not be confused with corrosion of the base metal. The corrosion protection classification achieved by the surface treatment shall be stated. Table 4 Corrosion protection classification 7 Template drilled hinges 7.1 General Full mortice template drilled hinges for use on metal doors and frames shall comply with the dimensional and other req
链接地址:https://www.31doc.com/p-3736137.html