《BS-9041-1978.pdf》由会员分享,可在线阅读,更多相关《BS-9041-1978.pdf(18页珍藏版)》请在三一文库上搜索。
1、BRITISH STANDARD BS 9041:1978 Incorporating Amendment No. 1 Rules for the preparation of Detail specifications for Gas filled microwave switching tubes of assessed quality: Tunable and broadband TR tubes and TR limiters Full assessment level Licensed Copy: London South Bank University, London South
2、Bank University, Fri Dec 08 02:29:54 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 9041:1978 BSI 02-2000 ISBN 0 580 34368 5 A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance
3、with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, pages 1 to 13 and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporat
4、ed. This will be indicated in the amendment table on the inside front cover. Amendments issued since publication Amd. No.Date of issueComments 2716August 1978Indicated by a sideline in the margin Licensed Copy: London South Bank University, London South Bank University, Fri Dec 08 02:29:54 GMT+00:00
5、 2006, Uncontrolled Copy, (c) BSI BS 9041:1978 BSI 02-2000i Contents Page 1Introduction1 2Scope1 3General1 Appendix Example Inspection drawing Broadband TR limiter12 Licensed Copy: London South Bank University, London South Bank University, Fri Dec 08 02:29:54 GMT+00:00 2006, Uncontrolled Copy, (c)
6、BSI ii blank Licensed Copy: London South Bank University, London South Bank University, Fri Dec 08 02:29:54 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 9041:1978 BSI 02-20001 1 Introduction This British Standard should be used with BS 9040, “Gas-filled microwave switching tubes of assessed quality
7、: generic data and methods of test”. The object of the rules in this standard is to ensure that all detail specifications for tunable and broadband TR tubes and TR limiters are closely similar to enable detail specifications to be readily compared. 2 Scope This standard lists the ratings, characteri
8、stics, inspection requirements and additional information which shall be included as minimum mandatory requirements in the detail specifications for tunable and broadband TR tubes and TR limiters at the full assessment level. The purpose of the detail specification is to describe fully a particular
9、tube so that the specification can be used contractually for the procurement of that tube, for acceptance testing and for circuit design and maintenance purposes. 3 General Detail specifications are prepared either by BSI of by manufacturers. They shall be prepared in accordance with the rules given
10、 in 3.1 to 3.4. The minimum information which is to be given in a detail specification for tunable and broadband TR tubes and TR limiters is given in the mandatory layout. All detail specifications shall be printed on A4 size paper. 3.1 Basic information. The information given in 3.1.1 to 3.1.9 shal
11、l appear on the first two pages of the detail specification as far as is practicable. This information is not for inspection purposes; inspection requirements are given in 3.2. 3.1.1 Originator of specification. Each detail specification shall give the name and address of the originator of the speci
12、fication. 3.1.2 Numbering of the detail specification. Each detail specification shall carry a distinguishing number made up of the number of this standard followed by a three-digit number to designate the particular detail specification. Where the detail specifications have been prepared by BSI the
13、 two portions of the distinguishing number shall be separated by the letter “N”, e.g. BS 9041 NXXX. When the detail specification has been prepared by a manufacturer BSI will issue a BS number which will be separated by the letter “F”, e.g. BS 9041 FXXX, to show that the detail specification has bee
14、n prepared by a manufacturer. The issue number and date of issue (month and year) of the detail specification shall be given and re-issues shall give the issue number and date of issue of the superseded document, all changes being clearly marked. 3.1.3 Description of the tube and intended applicatio
15、n. This shall be as shown on the first page of the mandatory layout for a detail specification. 3.1.4 Outline drawing (not for inspection purposes). An illustration of the tube showing overall dimensions shall be given as an aid to easy recognition and for comparison of the tube with other tubes. Co
16、de names of shapes, bases, etc., shall be in accordance with BS 4481) and terminal connections shall be given as appropriate. The symbols used shall be in accordance with the relevant British Standards or IEC publications. The location of the inspection drawing (see 3.3) shall be given. 3.1.5 Rating
17、s (not for inspection purposes). Any limiting conditions of use, e.g. mounting, shall be stated. The absolute system of ratings shall be used (see IEC publication 134). The ratings listed in the mandatory layout of this standard shall be stated. Additional ratings may be included at the manufacturer
18、s discretion but in all cases the values of the ratings and the conditions under which they apply shall be given. Any interdependence of ratings shall be stated. 3.1.5.1 Ratings (limiting values). These are defined as ratings which establish either a limiting capability or a limiting condition of us
19、e beyond which significant performance deterioration, life reduction and/or possible damage to the device may occur. NOTEThe limiting value may be either a maximum or minimum quantity and is referred to as a “maximum rating” or a “minimum rating” respectively. Such values do not necessarily define a
20、 frontier where one side gives satisfactory performance and the other immediate failure. 3.1.6 Characteristics (not for inspection purposes). The characteristics listed in the mandatory layout of this standard shall be stated. 1) BS 448, “Dimensions of electronic tubes and valves” Licensed Copy: Lon
21、don South Bank University, London South Bank University, Fri Dec 08 02:29:54 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 9041:1978 2 BSI 02-2000 Additional characteristics may be included at the manufacturers discretion but in all cases the values of the characteristics and the conditions under wh
22、ich they are measured shall be stated. 3.1.7 Related documents. Reference shall be made to BS 90002), BS 90403) and to any other British Standards or IEC publications which are called up in the detail specification but not already referenced in BS 9040. 3.1.8 Additional information. This part of the
23、 detail specification shall include any circuit diagrams, graphs and notes necessary to clarify any part of the detail specification. Also where any items such as those listed below are not fully defined in BS 9040 (and/or BS 9000 in some cases) additional details covering those items shall be given
24、 in the detail specification: a) terms and definitions; b) letter symbols; c) test procedures. The general principles contained in the relevant British Standard and/or IEC publications shall be followed when preparing such additional information. 3.1.8.1 Application data. The application data shall
25、be that which, in the view of the manufacturer, will provide adequate user information. This information shall be given on a voluntary basis and is not a mandatory requirement in the sense of forming part of the inspection procedure to meet the needs of the detail specification. However, it is the r
26、esponsibility of the manufacturer to ensure that the information given is correct and representative of current production. 3.1.9 Ordering information. The minimum ordering information required for tunable and broadband TR tubes and TR limiters covered by this standard shall be given. 3.2 Inspection
27、 requirements. The requirements of 2.2 of BS 9000-2:1972 shall apply and in addition, tests to be performed at qualification approval only shall be included in subgroup D7. 2) BS 9000, “General requirements for electronic parts of assessed quality”. 3) BS 9040, “Gas-filled microwave switching tubes
28、of assessed quality: generic data and methods of test”. Licensed Copy: London South Bank University, London South Bank University, Fri Dec 08 02:29:54 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 9041:1978 BSI 02-20003 1 Ratings (not for inspection purposes) Limiting values are absolute in accordan
29、ce with IEC publication 134. 2 Characteristics (not for inspection purposes) 3 Mounting position Any restriction to be slated. 4 Related documents BS 308, Engineering Drawing Practice. MANDATORY LAYOUT AND CONTENT FOR DETAIL SPECIFICATION ELECTRONIC COMPONENTS OF ASSESSED QUALITY: DETAIL SPECIFICATI
30、ON Outline and dimensions (in millimetres) (Not for inspection) GAS-FILLED MICROWAVE SWITCHING TUBE-TUNABLE/BROADBAND TR TUBE OR TR LIMITER (as applicable) aOutline drawing to show the overall dimensions FULL ASSESSMENT LEVEL MANUFACTURERS TYPE DESIGNATION NUMBER See Appendixa for inspection drawing
31、 Brief description to include the following: a -Band Mates with waveguide flange typea a To be completed by the specification writer. SymbolMin.Max.Units Limiting values Peak pulse powerPp aa kW Mean powerPav a W Pulse durationtP a 4s Operating temperature rangeTop aa C Storage temperature rangeTstg
32、 aa C Ambient pressure (absolute)p aa kN/m2 Shock (duration ams) a m/s2 Continuous vibration a m/s2 a To be completed by the specification writer. Typical values SymbolUnits Primer currentIpr a 4a Primer supply voltageVpr 1kV Total primer supply resistorRpr5.6M7 Auxiliary primer resistor (if fitted)
33、Rpr a M7 Built-in primer resistor (if fitted)Rpr a M7 Frequency rangef a to a GHz Primed insertion lossLpr a dB Spike leakage energyWs a nJ/pulse V.S.W.R.r a ratio a To be completed by the specification writer. Licensed Copy: London South Bank University, London South Bank University, Fri Dec 08 02:
34、29:54 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 9041:1978 4 BSI 02-2000 BS 9000, General requirements for electronic components of assessed quality. BS 9040, Gas-filled microwave switching tubes of assessed quality: generic data and methods of test. 5 Marking The marking of the tube and its pack
35、ing shall be in accordance with the requirements of 1.6 of BS 9040. 6 Ordering information Orders for this tube shall contain the following information: a) BS number, issue and date of this specification. b) manufacturers type designation. The order should contain details of any special requirements
36、. 7 Additional information (not for inspection purposes) Mounting details. Further information may be given at the manufacturers discretion. 8 Inspection requirements 8.1 Primer(s) if fitted, shall be energized for all electrical tests in accordance with 2.4.7 of BS 9040. 8.2 For reference to freque
37、ncy tolerances, see 2.4.12 of BS 9040. 8.3 For qualification approval, at least two tubes are required to meet the post endurance test limits after 3 months (each) storage. One defective out of three tubes tested is permitted. 8.4 Although qualification approval is granted on the above criteria, the
38、 full 12 months non-operating endurance test shall be carried out. At least two tubes are required to meet the post endurance test limits after 12 months (each) storage. The results of the full non-operating endurance test shall be appended to the qualification approval test report. NOTE TO SPECIFIC
39、ATION WRITERSIf tolerances are other than those specified in 2.4.12 of BS 9040, they are to be indicated, as appropriate. InspectionBS 9040 reference and conditions of testSymbolLimitsUnit Min.Max. Group ASubgroups A4, A5 not applicable Subgroup A0100 % inspection (i) Insertion loss (ii) Spike leaka
40、ge energy (iii) Amplitude recovery period 1006 1014 1016 fr= a to a GHz p= a mW max. f= a GHz Pp= a kW D=a tp1 = a 4s tp2 = a 4s f= a GHz Pp= a kW D= a tp= a 4s f(low power) = a GHz L Ws tr a a a dB nJ/pulse 4s a To be completed by the specification writer. Licensed Copy: London South Bank Universit
41、y, London South Bank University, Fri Dec 08 02:29:54 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 9041:1978 BSI 02-20005 InspectionBS 9040 reference and conditions of testSymbolLimitsUnit Min.Max. Subgroup A1Inspection level I, AQL 1.5 % Visual inspection2.2 Sub group A2Inspection level II, AQL 0.6
42、5 % (i) (a) Total leakagec power or (i) (b) 1013f = a GHz Pp= a kW D = a tp= a 4s Ptot a mW Flat leakagec power1015As in test (i) (a) abovePf1 a mW Subgroup A3Inspection level I, AQL 1.5 % (i) Ignition periodb (ii) (a) Primer currentbc or (ii) (b) Primer voltage dropbc (iii) VSWR 1001 1003 1005 1007
43、 fr = a to a GHz ti Ipr Vpd r a a a a a a s 4A V ratio (iv) Low power leakage (v) Tuning ranged 1012 1021 f = a GHz D = a tp= a 4s fr = a to a GHz P1p fr a a a mW GHz GROUP BSubgroups B2 to B6 and B8 not applicable Sub group B1Inspection level S-4, AQL 4 % Dimensions2.3In accordance with the inspect
44、ion drawing Subgroup B7Inspection level S-3, AQL 4 % Operating endurance2.7.3Duration = 160 h min. Ppk = a kW min. Post conditioning Primer currentbc or 1003As in subgroup A3Ipr aa 4A a To be completed by the specification writer. b If applicable. c Specification writer to select one of these tests;
45、 the first test is preferred. d Applicable to tunable items only. Licensed Copy: London South Bank University, London South Bank University, Fri Dec 08 02:29:54 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 9041:1978 6 BSI 02-2000 InspectionBS 9040 reference and conditions of testSymbolLimitsUnit Mi
46、n.Max. Subgroup B7 (contd) Primer voltage dropbc Insertion loss Spike leakage energy Amplitude recovery period 1005 1006 1014 1016 As in subgroup A3 As in subgroup A0 As in subgroup A0 As in subgroup A0 Vpd L Ws tr a a a a a V dB nJ/pulse 4s GROUP CSubgroups C2 and C4 to C6 not applicable Subgroup C
47、1Inspection level S-3, AQL 6.5 % Dimensions2.3In accordance with the inspection drawing Subgroup C3Inspection level S-4, AQL 4 % Robustness of terminations 2.6.9Torque or tensile as appropriate GROUP DSubgroups D4 and D6 not applicable Subgroup D1Inspection level S-4, AQL 6.5 % Inspection at 3-yearl
48、y intervals (i) Dimensions (ii) Weight (iii) Finish 2.3 In accordance with inspection drawing a (standard of finish required) Subgroup D2Inspection level S-4, AQL 6.5 % Inspection at 2-yearly intervals (i) Primer noise temperature (ii) Loaded Qd (iii) Arc loss 1004 1009 1011 f= a GHz f= a GHz PP= a
49、kW D = a tP= a 4s Tpr QL La a a a a K ratio dB (iv) Short circuit position1019f= a GHz Reference short circuit = a mm PP= a kW D = a tp= a 4s dsc aa mm a To be completed by the specification writer. b If applicable. c Specification writer to select one of these tests; the first test is preferred. d Applicable to tunable items only. Licensed Copy: London South Bank University, London South Bank University, Fri Dec 08 02:29:54 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 9041:197