1、BRITISH STANDARD BS 9251:2005 Sprinkler systems for residential and domestic occupancies Code of practice ICS 13.220.20 ? BS 9251:2005 This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 January 2005 BSI 31 January 2005 First published as DD 2
2、51 April 2000 First edition as BS 9251 January 2005 The following BSI references relate to the work on this British Standard: Committee reference FSH/18/2 ISBN 0 580 44816 9 Committees responsible for this British Standard The preparation of this British Standard was entrusted by Technical Committee
3、 FSH/18, Fixed firefighting systems, to Subcommittee FSH/18/2, Sprinkler systems, upon which the following bodies were represented: ABI Association of British Insurers Association of Building Engineers BASA British Automatic Sprinkler Association BRE/LPC Laboratories British Fire Consortium British
4、Plastics Federation British Pump Manufacturers Association British Fire Protection Systems Association Chief and Assistant Chief Fire Officers Association Copper Development Association District Surveyors Association Fire Sprinkler Association Home Office IFS Institute of Fire Safety London District
5、 Surveyors Association London Fire and Emergency Planning Authority National Fire Sprinkler Network ODPM represented by BRE ODPM Construction Directorate Powder Actuated Systems Association Water UK Co-opted member Amendments issued since publication Amd. No.DateComments BS 9251:2005 BSI 31 January
6、2005 i Contents Page Committees responsibleInside front cover Forewordii Introduction1 1Scope8 2Normative references8 3Terms and definitions8 4Consultation10 5Design11 6Installation, commissioning and documentation16 7Maintenance18 Annex A (normative) Hydraulic calculation19 Annex B (normative) Pipe
7、work support22 Bibliography23 Figure 1a) Typical mains fed sprinkler system installation control details (unmetered supply)2 Figure 1b) Typical mains fed sprinkler system installation control details For new buildings (metered domestic supply)3 Figure 2a) Typical in line fire pump fed sprinkler syst
8、em installation control details (unmetered supply)4 Figure 2b) Typical in line fire pump fed sprinkler system installation control details (metered domestic supply)5 Figure 3a) Typical stored water and fire pump fed sprinkler system installation control details (unmetered supply)6 Figure 3b) Typical
9、 stored water and fire pump fed sprinkler system installation control details (metered domestic supply)7 Figure 4 Typical sprinkler connection, installation control and monitoring details15 Table A.1 Pressure loss in 1 m of copper pipe for a water flow rate of 60 l/min19 Table A.2 Pressure loss in 1
10、 m of CPVC pipe for a water flow rate of 60 l/min19 Table A.3 Pressure loss in 1 m of steel pipe for a water flow rate of 60 l/min20 Table A.4 Values of C for steel, copper and CPVC20 Table A.5 The equivalent length of copper pipe for the pressure loss due to the bend for a water flow rate of 60 l/m
11、in20 Table A.6 Copper: equivalent lengths of pipe for fittings (in metres of pipe)21 Table A.7 Steel: equivalent lengths of pipe for fittings (in metres of pipe)21 Table A.8 CPVC: equivalent lengths of pipe for fittings (in metres of pipe)21 Table B.1 Maximum spacing of fixings for copper and stainl
12、ess steel pipework22 Table B.2 Maximum spacing of fixings for steel pipework22 Table B.3 Maximum spacing of fixings for CPVC pipework22 BS 9251:2005 ii BSI 31 January 2005 Foreword This British Standard has been prepared by a Task Group from Technical Committee FSH/18/2. It supersedes DD 251:2000, w
13、hich is withdrawn. It gives recommendations for the design, installation, components, water supplies, commissioning and maintenance of fire sprinkler systems for use specifically in residential and domestic occupancies. It is intended for the use of designers, engineers, architects, surveyors, contr
14、actors, installers and authorities having jurisdiction. Sprinkler protection for other buildings and industrial plant is specified in BS 5306-2 and BS EN 12845. Fire sprinkler systems for domestic and residential application are designed to provide an additional degree of protection of life and prop
15、erty, above that already achieved by the installation of smoke and/or fire detectors and systems. This British Standard presumes that the sprinkler protection will form part of an integrated fire safety system as part of the building design. Product certification/inspection/testing. Users of this Br
16、itish Standard are advised to consider the desirability of third-party certification/inspection/testing of product conformity with this British Standard. Appropriate conformity attestation arrangements are described in BS EN ISO 9001. Users seeking assistance in identifying appropriate conformity as
17、sessment bodies or schemes may ask BSI to forward their enquiries to the relevant association. The recommendations contained in this British Standard result from the best technical information available to the committee at the time of writing. Firefighting and life protection encompasses a wide fiel
18、d of endeavour and as such it is impracticable to cover every possible factor or circumstance that might affect implementation of this British Standard. Therefore the design and installation of any system should be entrusted to a suitably qualified and experienced sprinkler contractor. Attention is
19、drawn to the requirements of BS 6700 with special regard to back-flow prevention and to BS 1710 for guidance on identification and marking of pipework. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Complian
20、ce with a British Standard does not of itself confer immunity from legal obligations. Attention is drawn to the requirements of the Water Regulations 1, 2, 3. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, pages 1 to 23 to and a back cover. The BSI cop
21、yright notice displayed in this document indicates when the document was last issued. BS 9251:2005 BSI 31 January 2005 1 Introduction Sprinkler systems have demonstrated their value in protecting life and property in industrial and commercial applications for many years. The advent of sprinklers tha
22、t operate at an earlier stage in the development of a fire, plus the recognition that the largest numbers of deaths from fire occur in the home, have led to the introduction of sprinkler systems specifically designed for residential and domestic occupancies. A correctly designed and installed sprink
23、ler system can detect and control a fire at an early stage of development and activate an alarm. Operation of the system will rapidly reduce the rate of production of heat and smoke, allowing more time for the occupants to escape to safety or be rescued. This British Standard accordingly covers desi
24、gn, installation, components, water supplies, maintenance and testing of residential and domestic sprinkler systems installed for life safety purposes. Residential and domestic fire sprinkler systems are systems in accordance with this standard and consist of a water supply, backflow prevention valv