《BS-EN-122180-1996.pdf》由会员分享,可在线阅读,更多相关《BS-EN-122180-1996.pdf(28页珍藏版)》请在三一文库上搜索。
1、BRITISH STANDARD BS EN 122180:1996 Harmonized system of quality assessment for electronic components Sectional specification: Radio frequency coaxial connectors Series SSMC The European Standard EN 122180:1993 has the status of a British Standard ICS 33.120.30 Licensed Copy: sheffieldun sheffieldun,
2、 na, Sat Oct 28 08:24:08 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS EN 122180:1996 This British Standard, having been prepared under the direction of the Electrotechnical Sector Board, was published under the authority of the Standards Board and comes into effect on 15 August 1996 BSI 11-1998 The
3、 following BSI references relate to the work on this standard: Committee reference EPL/46/4 Draft announced in BSI News Update April 1996 ISBN 0 580 26170 0 Committees responsible for this British Standard The preparation of this British Standard was entrusted by Technical Committee EPL/46, Cables,
4、wires and waveguides, RF connectors and accessories for communication and signalling, to Subcommittee EPL/46/4, RF connectors, on which the following bodies were represented: AEA Technology BEAMA Electrical Cable and Conductor Accessory Manufacturers British Telecommunications plc Federation of the
5、Electronics Industry Ministry of Defence National Supervisory Inspectorate Society of Cable Television Engineers Amendments issued since publication Amd. No.DateComments Licensed Copy: sheffieldun sheffieldun, na, Sat Oct 28 08:24:08 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS EN 122180:1996 BSI 1
6、1-1998i Contents Page Committees responsibleInside front cover National forewordii Foreword2 Text of EN 1221805 List of referencesInside back cover Licensed Copy: sheffieldun sheffieldun, na, Sat Oct 28 08:24:08 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS EN 122180:1996 ii BSI 11-1998 National for
7、eword This British Standard has been prepared by Subcommittee EPL/46/4 and is the English language version of EN 122180:1993 Harmonized system of quality assessment for electronic components: Sectional specification: Radio frequency coaxial connectors Series SSMC, published by the Electronic Compone
8、nts Committee (CECC) of the European Committee for Electrotechnical Standardization (CENELEC). It is identical with CECC 22180:1993. Additional information. The following information on series SSMC connectors is reproduced from the preface of CECC 22180 Issue 2 which does not form part of this Europ
9、ean Standard. Series SSMC connectors have a characteristic impedance of 50 and are normally used for low-power applications, in conjunction with flexible coaxial cables having a dielectric diameter of 0,86 mm to 1,6 mm. The connectors are usable up to a frequency of at least 6 GHz, and may be used a
10、t higher frequencies if a reflection factor greater than 0,25 can be tolerated for straight connectors and 0,33 for right-angle styles. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application.
11、 Compliance with a British Standard does not of itself confer immunity from legal obligations. Cross-references Publication referred toCorresponding British Standard CECC 22000:1992BS CECC 22000:1993 Harmonized system of quality assessment for electronic components. Generic specification. Radio freq
12、uency coaxial connectors (Parts I, II and III) BS EN 60068 Environmental testing BS EN 60068-2 Test methods IEC 68-2-1:1990BS EN 60068-2-1:1993 Tests A. Cold BS 2011 Environmental testing Part 2.1 Tests IEC 68-2-13:1983Part 2.1M: 1984 Test M. Low air pressure IEC 68-2-30:1980Part 2.1Db: 1981 Test Db
13、 and guidance: Damp heat, cyclic (12 + 12 hour cycle) Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, the EN title page, pages 2 to 22, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had amendment
14、s incorporated. This will be indicated in the amendment table on the inside front cover. Licensed Copy: sheffieldun sheffieldun, na, Sat Oct 28 08:24:08 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 122180 November 1993 UDCSupersedes CECC 22 180 Issu
15、e 2:1993 Descriptors: Quality, electronic components, connectors English version Sectional specification: Radio frequency coaxial connectors. Series SSMC Spcification intermdiaire: Connecteurs coaxiaux pour frquence radiolectrique. Srie SSMC Rahmenspezifikation: Hochfrequenz-Koaxial-Steckverbinder.
16、Serie SSMC This European Standard was approved by the CENELEC Electronic Components Committee (CECC) on 1 November 1993. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard wi
17、thout any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the General Secretariat of the CECC or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in an
18、y other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CECC General Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Denmark, Finland, Franc
19、e, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom. The membership of the CECC is identical, with the exception of the national electrotechnical committees of Greece, Iceland and Luxembourg. CECC CENELEC Electronic Co
20、mponents Committee Comit des Composants Electroniques du CENELEC CENELEC-Komitee fr Bauelemente der Elektronik General Secretariat: Gartenstr. 179, D-60596 Frankfurt am Main 1993 Copyright reserved to CENELEC members Ref. No. EN 122180:1993 E Licensed Copy: sheffieldun sheffieldun, na, Sat Oct 28 08
21、:24:08 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 122180:1993 BSI 11-1998 2 Foreword The CENELEC Electronic Components Committee (CECC) is composed of those member countries of the European Committee for Electrotechnical Standardization (CENELEC) who wish to take part in a harmonized System for e
22、lectronic components of assessed quality. The object of the System is to facilitate international trade by the harmonization of the specifications and quality assessment procedures for electronic components, and by the grant of an internationally recognized Mark, or Certificate, of Conformity. The c
23、omponents produced under the System are thereby acceptable in all member countries without testing. This European Standard was prepared by CECC WG 22, RF Connectors. The text of the draft based on document CECC 22 180 Issue 2:1993 was submitted to the formal vote for conversion to a European Standar
24、d; together with the voting report, circulated as document CECC (Secretariat) 3433 it was approved by CECC as EN 122180 on 1 November 1993. The following dates were fixed: Contents Page Foreword2 Section 1. Scope5 Section 2. Mating face and gauge information6 2.1Dimensions General purpose connectors
25、6 2.2Gauges for general purpose connectors7 2.3Dimensions Standard test connectors (Grade 0)8 Section 3. Properties9 3.1Ratings and characteristics9 Section 4. Test conditions and severities12 4.1Measurement and recovery conditions12 4.2Visual examination12 4.3Dimensions12 4.4Electrical tests and me
26、asurements12 4.5Mechanical tests and measurements13 4.6Environmental tests and measurements15 4.7Endurance tests19 4.8Resistance to solvents and contaminating fluids19 Section 5. Quality assessment procedures20 5.1Test schedules and inspection requirements20 Figure 3 Gauge pin for centre contact of
27、socket connector7 latest date of announcement of the EN at national level(doa) 1994-02-07 latest date of publication of an identical national standarda(dop) 1994-08-07 latest date of withdrawal of conflicting(dow) 1995-08-07 a National standard (excluding national implementation of IECQ specificatio
28、ns). Licensed Copy: sheffieldun sheffieldun, na, Sat Oct 28 08:24:08 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 122180:1996 BSI 11-19983 Document numbering for r.f. connector specifications follows 2.2 of CECC 00 700:Section IV, in order to permit the issue of more than nine sectional specificati
29、ons. The approved numbering system applicable to r.f. connector specifications is illustrated in the diagram below. Licensed Copy: sheffieldun sheffieldun, na, Sat Oct 28 08:24:08 GMT+00:00 2006, Uncontrolled Copy, (c) BSI 4 blank Licensed Copy: sheffieldun sheffieldun, na, Sat Oct 28 08:24:08 GMT+0
30、0:00 2006, Uncontrolled Copy, (c) BSI EN 122180:1996 BSI 11-19985 Section 1. Scope This sectional specification (SS) provides information and rules for the preparation of detail specifications (DS) for miniature screw-coupled coaxial connectors Series SSMC. It prescribes mating-face dimensions for g
31、eneral purpose connectors, dimensional details for standard test connectors, Grade 0, together with gauging information and the mandatory tests, selected from CECC 22 000, applicable to all DSs relating to Series SSMC connectors. This specification indicates the recommended performance characteristi
32、cs to be considered when writing a DS, and covers test schedules and inspection requirements for Assessment Levels H, M and U. Licensed Copy: sheffieldun sheffieldun, na, Sat Oct 28 08:24:08 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 122180:1996 6 BSI 1998 Section 2. Mating face and gauge informa
33、tion 2.1 Dimensions general purpose connectors All undimensioned pictorial configurations are for reference purposes only. Licensed Copy: sheffieldun sheffieldun, na, Sat Oct 28 08:24:08 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 122180:1996 BSI 19987 Inch dimensions are original dimensions. All
34、undimensioned pictorial configurations are for reference purposes only. 2.2.1 Gauge for female centre contact Test procedure (see 4.5.1 of CECC 22 000). Gauge A shall be inserted once only into the female centre contact. This is a sizing operation. After this, gauge B shall be inserted into the fema
35、le centre contact. The contact shall support the mass of the gauge in a vertical downward attitude. Note (for information only): Gauge A is used for qualification approval tests only. The minimum diameter of gauge A corresponds to the maximum diameter of a male contact pin. Figure 3 Gauge pin for ce
36、ntre contact of socket connector (for dimension “a” see below) Gauge A maximum material for sizing purposes Gauge B minimum material for measurement of gauge retention force Mass (weight) of gauge: 16 1 g Ref. mminmmin min.max.min.max.min.max.min.max. a 0,3810,3840,0150,01510,3530,3560,01390,014 Mat
37、erial: Steel, polished surface roughness Ra = 0,4 m (16 in) max. Licensed Copy: sheffieldun sheffieldun, na, Sat Oct 28 08:24:08 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 122180:1996 8 BSI 11-1998 2.3 Dimensions Standard test connectors (Grade 0) (see 4.4.1 of CECC 22 000) All undimensioned pict
38、orial configurations are for reference purposes only. Licensed Copy: sheffieldun sheffieldun, na, Sat Oct 28 08:24:08 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 122180:1996 BSI 11-19989 Section 3. Properties 3.1 Ratings and Characteristics (see 2.3 of CECC 22 000) (including limiting conditions o
39、f use) The blank detail specification(s) relating to Series SSMC connectors shall list the following properties and the specific values shall be entered by the specification writer. Properties not applicable to a particular connector style shall be marked “na”. The values indicated below give the re
40、commended requirements and properties. Ratings and characteristics CECC 22 180 clause ValueRemarks Electrical4.4 Frequency rangeUp to 6 GHzGrade 2 connectors Reflection factora4.4.1 straight styles 0,1Up to 1 GHz right angle styles 0,2Up to 1 GHz straight styles 0,15Up to 3 GHz right angle styles 0,
41、24Up to 3 GHz straight styles 0,25Up to 6 GHz right angle styles 0,33Up to 6 GHz component mounting stylesSee DS solder bucketna PCB mounting styles Centre contact resistance4.4.2 5 mInitial 15 mAfter conditioning Outer conductor continuity4.4.3 2,5 mInitial 7,5 mAfter conditioning Insulation resist
42、ance4.4.4 1 GInitial 200 MAfter conditioning Proof voltage at sea levelbc4.4.586 kPa to 106 kPa Cable type: IEC 96-50-1-1, 1-2500 V Semi-rigid cables4.4.5 0,056 in or 1,42 mm dia.250 V 0,085 in or 2,16 mm dia.500 V Licensed Copy: sheffieldun sheffieldun, na, Sat Oct 28 08:24:08 GMT+00:00 2006, Uncon
43、trolled Copy, (c) BSI EN 122180:1996 10 BSI 11-1998 Electrical4.4 Proof voltage at 4,4 kPabc4.6.54,4 kPa approx. equivalent to 20 km it must then be prescribed in the DS. requirements:1)Centre contact Tinning of the termination shall occur within the first 3 s, but the bit shall be applied for 5 s.
44、After soldering the connector shall be visually examined. There shall be no damage, displacement or loosening of parts. 2)Outer conductor For soldering bodies the tinning requirements may differ from those for the centre contact but shall be prescribed in the DS. After soldering, the connector shall
45、 be visually examined. There shall be no damage, displacement or loosening of parts. (2)Resistance to soldering heat conditions:see 4.6.1 2) of CECC 22 000. 1)Centre contact Using Method 2, soldering iron, size A bit, the bit shall be applied to the solder bucket or tag for a period of 10 s with no
46、thermal screen or heat sink unless prescribed in the DS. 2)Outer conductor For soldering conductor bodies the requirements may differ from those for the centre contact. Appropriate details shall be given in the DS including any thermal screen or heat sink which shall be used. requirements:1)Centre c
47、ontact 2)Outer conductor The connector shall be visually examined. There shall be no damage, displacement or loosening of parts. Not normally applicable to Series SSMC connectors. Licensed Copy: sheffieldun sheffieldun, na, Sat Oct 28 08:24:08 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 122180:199
48、6 16 BSI 11-1998 4.6.3 Vibration 4.6.4 Shock 4.6.5 Climatic tests conditions:see 4.6.3 of CECC 22 000. The test shall be carried out on mated sets of connectors. The normal coupling of 0,2 Nm0,23 Nm shall be applied. Mounting shall be in accordance with 4.1.1 of CECC 22 000, in such a manner that th
49、e specimens can be vibrated in two mutually perpendicular directions, one of which shall be the longitudinal axis of the connectors. Cables shall be clamped to the test table in axial alignment at a distance of (90 10) mm from each cable outlet. The free end of the cable shall be restrained from motion by clamping to a rigid support. Unless otherwise prescribed in the DS the following conditions shall apply: test procedure: endurance by sweeping in accordance with sub-clause 8