1、BRITISH STANDARD BS EN 12365-4:2003 Building hardware Gasket and weatherstripping for doors, windows, shutters and curtain walling Part 4: Recovery after accelerated ageing test method The European Standard EN 12365-4:2003 has the status of a British Standard ICS 91.060.50; 91.190 ? Licensed Copy: s
2、heffieldun sheffieldun, na, Sat Oct 28 09:36:32 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS EN 12365-4:2003 This British Standard, was published under the authority of the Standards Policy and Strategy Committee on 4 October 2003 BSI 4 October 2003 ISBN 0 580 42745 5 National foreword This British
3、 Standard is the official English language version of EN 12365-4:2003. The UK participation in its preparation was entrusted by Technical Committee B/538, Doors, windows, shutters, hardware and curtain walling, to Subcommittee B/538/4, Building hardware, which has the responsibility to: A list of or
4、ganizations represented on this subcommittee can be obtained on request to its secretary. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards C
5、orrespondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does
6、not of itself confer immunity from legal obligations. aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European develop
7、ments and promulgate them in the UK. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 11 and a back cover. The BSI copyright notice displayed in this document indicates when the document was last issued. Amendments issued since publication
8、Amd. No. DateComments Licensed Copy: sheffieldun sheffieldun, na, Sat Oct 28 09:36:32 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 12365-4 September 2003 ICS 91.060.50; 91.190 English version Building hardware - Gasket and weatherstripping for doors
9、, windows, shutters and curtain walling - Part 4: Recovery after accelerated ageing test method Quincaillerie pour le btiment - Profils dtanchit de vitrage et entre ouvrant et dormant pour portes, fentres, fermetures et faades rideaux - Partie 4: Mthode dessai pour dterminer la reprise lastique aprs
10、 vieillissement Baubeschlge - Dichtungen und Dichtungenprofile fr Fenster, Tren und andere Abschlsse sowie vorgehngte Fassaden - Teil 4: Langzeitrckstellvermgen, Prfverfahren This European Standard was approved by CEN on 1 August 2003. CEN members are bound to comply with the CEN/CENELEC Internal Re
11、gulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Management Centre or to any CEN member. This E
12、uropean Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the Management Centre has the same status as the official versions. CEN members are the nat
13、ional standards bodies of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Slovakia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE
14、NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: rue de Stassart, 36 B-1050 Brussels 2003 CENAll rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 12365-4:2003 E Licensed Copy: sheffieldun sheffieldun, na, Sat Oct 28 09:36:32
15、GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 12365-4:2003 (E) 2 Contentspage Foreword.3 1Scope4 2Normative references4 3Terms and definitions.4 4Requirements 4 4.1Maximum working temperature range4 4.2Recovery after accelerated ageing5 5Test apparatus.5 5.1Compression block.5 5.2Heating chamber.5 6
16、Test procedure 5 6.1Test measurements.5 6.2Test samples6 6.2.1General.6 6.2.2Shape and size of test sample.6 6.2.3Conditioning6 6.3Preparation of test pieces 6 7Test method.6 7.1General.6 7.2Temperature and humidity.6 7.3Determination of free height7 7.4Deflection recovery test .7 7.5Re-measure free
17、 height 7 7.6Expression of results8 7.7Determination of final result 8 8Test report8 Annex A (informative) Typical compression block for deflection recovery test9 Annex B (informative) Flow chart of test procedure.10 Bibliography .11 Licensed Copy: sheffieldun sheffieldun, na, Sat Oct 28 09:36:32 GM
18、T+00:00 2006, Uncontrolled Copy, (c) BSI EN 12365-4:2003 (E) 3 Foreword This document (EN 12365-4:2003) has been prepared by Technical Committee CEN/TC 33 “Doors, windows, shutters, building hardware and curtain walling“, the secretariat of which is held by AFNOR. This European Standard shall be giv
19、en the status of a national standard, either by publication of an identical text or by endorsement, at the latest by March 2004, and conflicting national standards shall be withdrawn at the latest by March 2004. EN 12365, Building hardware Gaskets and weatherstripping, consists of the following part
20、s: Part 1: Performance requirements and classification; Part 2: Linear compression test method; Part 3: Deflection recovery test method; Part 4: Recovery after accelerated ageing test method. This Standard is one of a series of European Standards for building hardware. Annexes A and B are informativ
21、e. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Luxembourg, Malta, Nethe
22、rlands, Norway, Portugal, Slovakia, Spain, Sweden, Switzerland and the United Kingdom. Licensed Copy: sheffieldun sheffieldun, na, Sat Oct 28 09:36:32 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 12365-4:2003 (E) 4 1 Scope This Part of this European Standard specifies the method to be used to selec
23、t, prepare, condition and test samples of typical raw materials, to determine the long term performance of gaskets and weatherstripping under the conditions laid down in the test after ageing at the maximum working temperature. The test has been devised to cover all likely raw materials. 2 Normative
24、 references This European Standard incorporates by dated or undated reference, provisions from other publications. These normative references are cited at the appropriate places in the text, and the publications are listed hereafter. For dated references, subsequent amendments to or revisions of any
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS EN 12365 2003
链接地址:https://www.31doc.com/p-3737198.html