1、BRITISH STANDARD BS 9526 N0001: 1978 Specification for Multi-contact edge socket electrical connectors Single or double sided, closed ended, replaceable contacts, through-board solder or wire wrap terminations Full assessment level UDC 621.315.683:621.316.541 Licensed Copy: London South Bank Univers
2、ity, London South Bank University, Fri Dec 08 04:16:05 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 9526 N0001:1978 BSI 10-1999 ISBN 0 580 09849 4 A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct
3、application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, pages 1 to 26 and a back cover. This standard has been updated (see copyright date) and may have h
4、ad amendments incorporated. This will be indicated in the amendment table on the inside front cover. Amendments issued since publication Amd. No.DateComments Licensed Copy: London South Bank University, London South Bank University, Fri Dec 08 04:16:05 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 9
5、526 N0001:1978 BSI 10-1999i Contents Page 1Pattern number1 2Description of component and intended application1 3Marking of the connector and package2 4Related documents2 5Ordering information3 6Outline drawings3 7Ratings3 8Characteristics4 9Certified test records (CTRs)4 10Additional information4 11
6、Quality assessment procedure5 12Inspection requirements5 Appendix A Outline drawings13 Appendix B Grouping of preferred specimens of minimum quantities for Group D tests22 Appendix C Method of test for termination torsion23 Appendix D Method of test for guide key retention24 Appendix E Method of tes
7、t for static load (mating)25 Appendix F Method of test for moulding strength26 Licensed Copy: London South Bank University, London South Bank University, Fri Dec 08 04:16:05 GMT+00:00 2006, Uncontrolled Copy, (c) BSI ii blank Licensed Copy: London South Bank University, London South Bank University,
8、 Fri Dec 08 04:16:05 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 9526 N0001:1978 BSI 10-19991 This specification shall be read in conjunction with BS 9520. 1 Pattern number The specification number without the letters BS is used as the pattern number. This range of connectors is known as Pattern 9
9、526 N0001. 2 Description of component and intended application Multi-contact edge socket connectors with 2.54 mm contact spacing, closed ends, and moulded fixing flanges. Intended for use with single- or double-sided printed boards of 1.42 mm to 1.80 mm thickness. The connectors are available in siz
10、es up to a maximum of 80 contacts per side. Front or rear removable/replaceable contacts are available in the connector range with front or rear release for each direction of removal. Replacement contacts and keys used with this range of connectors shall be identical with the originals. The method o
11、f contact removal and replacement and the tools required will depend upon the design of individual connectors. The preferred method of location or polarization is by guide key(s). Each key replaces an opposite pair of contacts. (See clause 9.) One such key shall be provided for each connector. ELECT
12、RONIC COMPONENTS OF ASSESSED QUALITY: DETAIL SPECIFICATION ELECTRICAL CONNECTORS FULL ASSESSMENT LEVEL MULTI-CONTACT EDGE SOCKET SINGLE- OR DOUBLE-SIDED, CLOSED ENDED, WITH REPLACEABLE CONTACTS, THROUGH-BOARD SOLDER OR WIRE-WRAP TERMINATIONS TYPICAL CONNECTOR (SEE A.1 FOR OUTLINE DRAWINGS)ENVIRONMEN
13、TAL CATEGORY 55/125/21 Licensed Copy: London South Bank University, London South Bank University, Fri Dec 08 04:16:05 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 9526 N0001:1978 2 BSI 10-1999 3 Marking of the connector and package The marking shall be in accordance with 1.1.6 of BS 9520. The indiv
14、idual reference number required by 1.1.6 3) consists of abbreviations to identify individual connectors as follows: Example reference number S 6000 80 B W A C XX Packaging shall include the manufacturers assembly and contact replacement instructions. Full instructions for the removal and replacement
15、 of contacts and keys shall be provided by the manufacturer. Packages of replacement parts shall include an outline drawing showing salient dimensions. 4 Related documents BS 308, Engineering drawing practice. BS 4393, Tin or tin-lead coated copper wire. BS 4584, Metal-clad base materials for printe
16、d circuits. Style number:As shown in A.2. This is the control drawing number with the prefix CC/deleted. Number of ways:Digits denoting the number of contacts along one side of the connector. Single- or double-sided and active contact row: A = single-sided, side A active, single row of terminations
17、B = single-sided, side B active, single row of terminations E = single-sided, side A active, double row of terminations F = single-sided, side B active, double row of terminations D = double-sided, both sides active Termination style:S = solder spill for wire W = wire wrap T = through-board solder,
18、short spill L = through-board solder, long spill Contact finish:A = hard acid gold or hard acid gold alloy Contact removal/replacement system: A = rear release/front removable/replaceable contacts B = rear release/rear removable/replaceable contacts C = front release/front removable/replaceable cont
19、acts D = front release/rear removable/replaceable contacts Variant:Digits identifying an individual connector, parts and associated tools for replacement purposes. As in BS 9002. Licensed Copy: London South Bank University, London South Bank University, Fri Dec 08 04:16:05 GMT+00:00 2006, Uncontroll
20、ed Copy, (c) BSI BS 9526 N0001:1978 BSI 10-19993 BS 6001, Sampling procedures and tables for inspection by attributes. BS 9000, General requirements for electronic components of assessed quality. BS 9520, Electrical connectors of assessed quality for frequencies below 3 MHz: Generic data and methods
21、 of test. BS 9760, Printed circuits of assessed quality: Generic data and methods of test: Capability approval procedures and rules. PD 9002, BS 9000 component selection guide. 5 Ordering information The following information is to be given when ordering parts to this specification. a) The number of
22、 this detail specification. b) The individual (type) reference number as described in clause 3 of this detail specification. c) Details of marking which may be required in addition to that specified in clause 3 of this detail specification. d) Details of any requirements, e.g. contact omission plans
23、, additional contacts or keys, etc. 6 Outline drawings See Appendix A of this specification for the following. A.1 Outline dimensions, mass, board piercing and panel cut-out details A.2 Termination styles and dimensions A.3 Printed board layout, edge dimensions, and guide key applications A.4 Test b
24、oard details and dimensions A.5 Gauges NOTEOutline drawings include a cross-reference to the relevant National Supervising Inspectorate control drawings. 7 Ratings 7.1 Electrical Current1). Maximum current per individual contact in isolation: At ambient temperature 25 C: shall not exceed 3 A At maxi
25、mum ambient temperature 85 C: shall not exceed 1.5 A Maximum current per contact through all contacts simultaneously: At ambient temperature 25 C: shall not exceed 1.5 A At maximum ambient temperature 85 C: shall not exceed 1.0 A Voltage 1) The printed board and wire rating will usually be the limit
26、ing factors. Sea level 1 013 mbara 8 500 m 300 mbar Working voltageb (nominal) d.c. or a.c. peak 350250 Voltage proof d.c. or a.c. peak 1 050500 a 1 mbar = 102 N/m2= 100 Pa b Establishment of electrical safety factors, when the connector is used at other than the working voltage (nominal), is the re
27、sponsibility of the user. Licensed Copy: London South Bank University, London South Bank University, Fri Dec 08 04:16:05 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 9526 N0001:1978 4 BSI 10-1999 7.2 Environmental: 7.3 Endurance: 8 Characteristics 8.1 Connector range (See A.1 and A.2.) 8.2 Electric
28、al: 8.3 Mechanical: 8.4 Fluid resistance. The connectors are resistant to the following fluids listed in Appendix E of BS 9520: Isopropanol, 1,1,2-trichloro trifluoroethane, 1,1,1-trichloroethane, and trichloroethylene. 9 Certified test records (CTRs) Certified test records shall be prepared in acco
29、rdance with 1.1.11 of BS 9520. 10 Additional information 10.1 Guide keys (locating). It is possible for mismatching to occur with this range of connectors and the mating printed boards at extremes of tolerance, under the application of practical tolerancing, unless guide keys are used. Where practic
30、able, guide keys should be situated near the centre of the connector. Environmental classification55/125/21 Low air pressure severity301 mbar Vibration severitya10 Hz to 500 Hz, 0.75 mm/10gn, duration 6 h Shock severityNA Acceleration severityNA Bump severity390 m/s2(40gn) 1 000 10 bumps a The vibra
31、tion test is carried out using an assessment board (see A.4 of this specification). In practice, the vibration performance will vary with the size and weight of board used, and also with the method of mounting the connector. Mechanicala250 operations High temperature long term (current as in 6.1) 1
32、000 h at 85 C High temperature short term (no electrical load) 250 h at 125 C a The mechanical endurance test is carried out using a gauge (see A.5 of this specification). Endurance with a printed board is critically dependent upon the preparation of the board particularly the leading edge, and also
33、 the type of plating used. Maximum contact resistance (initially)15 m7 Maximum contact resistance (after conditioning)20 m7 Minimum insulation resistance (initially) 100 000 M7 (method A) 1 000 M7 (method B) Minimum insulation resistance (hot and after conditioning) 100 M7 (method B) Engaging and se
34、parating force, connectora2.8 N (0.63 lbf) max. per contact pair 0.2 N (0.045 lbf) min. per contact pair Contact retention (in insert) (moulding) Termination styles T and W20 N (4.50 lbf) min. Termination style S10 N (2.25 lbf) min. Contact holding force gauge mass15.3 g Guide key (locating) retenti
35、on10 N (2.25 lbf) Static load (mating)4 N (0.90 lbf) per contact pair a These values should be multiplied by the number of contact pairs in a particular connector to obtain the total engaging and separating forces for that connector. Force values refer to the use of gauges. Licensed Copy: London Sou
36、th Bank University, London South Bank University, Fri Dec 08 04:16:05 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 9526 N0001:1978 BSI 10-19995 10.2 Guide keys (polarizing). Polarization is effected by additional guide keys fitted by the user as required in place of contacts. (See A.3.2.) 11 Qualit
37、y assessment procedure Group C tests need not be carried out for Qualification Approval or when subsequent Group D tests are performed. 12 Inspection requirements Samples, subjected to tests in subgroups marked “(D)” shall not be accepted for release under BS 9000 (see 2.6.5 of BS 9000-1). Unless, o
38、therwise specified, tests shall be performed at an ambient temperature of between 15 C and 35 C. Fitting and wiring of contacts shall be in accordance with the manufacturers instructions. PTFE extruded insulation equipment wire to BS G210 shall be used. (To ensure that the wiring operation has been
39、carried out satisfactorily it is advisable to apply insulation resistance and contact resistance tests.) InspectionBS 9520:1974 reference and conditions of testRequirements as in BS 9520 Group ATo be applied on a sampling basis lot-by-lot except Subgroup A0. Subgroups A2 and A3 not applicable Subgro
40、up A0100 % inspection Visual examination1.2.2 1)As in 1.2.2 1) Subgroup A1Inspection level S-3, AQL 1.5 % Visual examination1.2.2 2)As in 1.2.2 2) Subgroup A4Inspection level S-3, AQL 1.5 % Voltage proof1.2.4.4Method A or B. Unmated. Voltage as specified in 7.1 of this specification. Duration = 5 s.
41、 As in 1.2.4.4 Subgroup A5 CTR information1.1.11The result of Subgroup A1 shall be reported as attributes information Group BTo be applied on a sampling basis lot-by-lot. Subgroups B3 to B7 are not applicable. Connectors shall have contacts fitted and wired as required for tests. Subgroup B1Inspecti
42、on level S-4, AQL 1.5 % Insulation resistance Engaging and separating force, connector Contact holding force 1.2.4.3 1.2.5.2 1.2.5.8 Method A or B (500 50 V) Forces as specified in 8.3 of this specification using gauges as prescribed in A.5 of this specification. With 10 sizings and using gauges as
43、prescribed in A.5 of this specification. 1 000 M7 min. As in 1.2.5.2 As in 1.2.5.8 Licensed Copy: London South Bank University, London South Bank University, Fri Dec 08 04:16:05 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 9526 N0001:1978 6 BSI 10-1999 InspectionBS 9520:1974 reference and condition
44、s of testRequirements as in BS 9520 Subgroup B2 (D)Inspection level S-4, AQL 4 % Specimens from Subgroup B1 may be used. Solderinga Contact resistance 1.2.6.6 1.2.4.1 1) Method 1 Recovery period = 1 h Using gauges as prescribed in A.5 of this specification. Satisfactory tinning. No loosening of part
45、s or other damage such as would impair performance. 15 m7 max. Subgroup B8 CTR information1.1.11Results from the tests in Subgroups B1 and B2 shall be reported as attributes information. Group CTo be applied on a sampling basis at three monthly intervals. Subgroups C2, C3 and C4 are not applicable.
46、The issue number of the manufacturing drawing shall be checked against that on the approval certificate. Subgroup C1Inspection level S-3, AQL 4 % Dimensions, outline1.2.3.1In addition wire wrap and through-board termination positions shall be checked using the gauges prescribed in A.5 of this specif
47、ication. Dimensions as specified in A.1 and A.2 of this specification. The terminations shall accept the gauges. Subgroup C5 (D)Inspection level S-3, AQL 4 % Mechanical endurance High temperature endurance Insulation resistance (hot) 1.2.7.1 1.2.7.2 1.2.4.3 250 operations at 15 operations per minute
48、 maximum, using gauges as prescribed in A.5 of this specification. 250 h duration at 125 C. No electrical load and unmated. During the conditioning the following measurements shall be made: Method B (500 50 V). Unmated at 125 C. Measured 8 times at intervals of not less than 24 h. 100 M7 min. a Appl
49、icable only to connectors having terminations intended to be soldered. Licensed Copy: London South Bank University, London South Bank University, Fri Dec 08 04:16:05 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 9526 N0001:1978 BSI 10-19997 InspectionBS 9520:1974 reference and conditions of testRequirements as in BS 9520 Subgroup C5 (D) (contd) Final measurementsAfter 1 1/2 h 2 h recovery Contact resistance Voltage proof Engaging and separating force, connector Visual examination 1.2.4.1 1) 1.2.4.4 1.2.5.2 1.2.2 3) 1.2.2 4) Using gauges as presc