《BS-8303-2-1994.pdf》由会员分享,可在线阅读,更多相关《BS-8303-2-1994.pdf(8页珍藏版)》请在三一文库上搜索。
1、BS 8303 : Part 2 : 1994 BRITISH STANDARD | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | N NO O C CO OP PY YI IN NG G I IN N A AN NY Y F FO OR RMM WWI IT TH HO OU UT T WWR RI IT TT TE EN N P PE ER RMMI IS SS SI IO ON N F
2、 FR RO OMM B BS SI I Installation of domestic heating and cooking appliances burning solid mineral fuels Part 2. Specification for installing and commissioning on site Licensed Copy: London South Bank University, London South Bank University, Fri Dec 08 06:10:40 GMT+00:00 2006, Uncontrolled Copy, (c
3、) BSI This British Standard, having been prepared under the direction of the Engineering Sector Board, was published under the authority of the Standards Board and comes into effect on 15 January 1995 BSI 1995 First published, as CP 403, August 1952 Second edition, October 1974 Third edition, as BS
4、8303, June 1986 Fourth edition, January 1995 The following BSI references relate to the work on this standard: Committee reference RHE/28 Draft for comment 91/82857 DC ISBN 0 580 22712 X BS 8303 : Part 2 : 1994 Amendments issued since publication Amd. No.DateText affected Committees responsible for
5、this British Standard The preparation of this British Standard was entrusted by the Engineering Sector Board to Technical Committee RHE/28, upon which the following bodies were represented: Association of British Solid Fuel Appliance Manufacturers British Ceramic Tile Council British Coal Corporatio
6、n Consumer Policy Committee of BSI Department of Energy (Energy Efficiency Office) Department of the Environment HETAS Ltd Incorporated Association of Architects and Surveyors Low Temperature Coal Distillers of Great Britain Ltd. METCOM National Fireplace Manufacturers Association National Society f
7、or Clean Air Real Fire Association Solid Smokeless Fuels Federation Waterheater Manufacturers Association Coopted members Licensed Copy: London South Bank University, London South Bank University, Fri Dec 08 06:10:40 GMT+00:00 2006, Uncontrolled Copy, (c) BSI i BS 8303 : Part 2 : 1994 Contents Page
8、Committees responsibleInside front cover Foreword2 Specification 1Scope3 2Definitions3 3References3 4Exchange of information3 5Checking, handling and site storage of materials and components3 6Co-ordination of work and installation preparation3 7Installation work on site4 8Commissioning of the insta
9、llation4 9Handover4 List of referencesInside back cover Licensed Copy: London South Bank University, London South Bank University, Fri Dec 08 06:10:40 GMT+00:00 2006, Uncontrolled Copy, (c) BSI 2 BS 8303 : Part 2 : 1994 Foreword This Part of BS 8303 has been prepared under the direction of the Engin
10、eering Sector Board and together with BS 8303 : Parts 1 and 3 supersedes BS 8303 : 1986 which is withdrawn. BS 8303 covers the installation of domestic heating and cooking appliances burning solid mineral fuel. BS 8303 : Part 1 details the design specification to be followed by the installation desi
11、gner, when developing an acceptable appliance installation design for the particular application. This Part of BS 8303 specifies the practices to be followed when installing the appliance in accordance with the design specification. It reflects good site supervision and working practices. BS 8303 :
12、Part 3 gives guidance and recommendations to the designer and installer on options to be identified and the methods of achieving a safe and satisfactory installation. It also gives important guidance on other matters including maintenance and cleaning. BS 8303 does not deal with design or installati
13、on of hot water heating systems or hot water supply systems. However, where the appliance involves hot water services, attention is drawn to BS 5449 : 1990. Attention is drawn to the need to ensure compliance with all local and general regulations as they affect the installation, including the follo
14、wing: planning permission; Building Regulations 1; Clean Air Act 2; Gas Safety (Installation and Use) Regulations 3. Compliance with a British Standard does not itself confer immunity from legal obligations. Licensed Copy: London South Bank University, London South Bank University, Fri Dec 08 06:10:
15、40 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 8303 : Part 2 : 1994 3 Specification 1 Scope This Part of BS 8303 specifies the procedures to be followed for on-site installation and testing of domestic heating and cooking appliances burning solid mineral fuels. 2 Definitions For the purposes of th
16、is Part of BS 8303, the definitions given in BS 1846 : Part 1 : 1994 apply. 3 References 3.1 Normative references This Part of BS 8303 incorporates, by dated or undated reference, provisions from other publications. These normative references are made at the appropriate places in the text and the ci
17、ted publications are listed on the inside back cover. For dated references, only the edition cited applies; any subsequent amendments to or revisions of the cited publication apply to this Part of BS 8303 only when incorporated in it by amendment or revision. For undated references, the latest editi
18、on applies, together with any amendments. 3.2 Informative references This Part of BS 8303 refers to other publications that provide information or guidance. Editions of these publications current at the time of issue of this standard are listed on the inside back cover, but reference should be made
19、to the latest editions. 4 Exchange of information The installer shall be in possession of the design specification, produced by the designer, for the installation of the appliance in accordance with BS 8303 : Part 1 : 1994 prior to commencing work. 5 Checking, handling and site storage of materials
20、and components 5.1 Checking 5.1.1 Delivery of materials Delivery tickets and certificates shall be checked against the design specification. The condition of the appliance, materials and components received shall be examined. If any item is damaged, or is not as specified, the supplier shall be cont
21、acted immediately. 5.1.2 Before installation The following shall be checked before commencing work; the manufacturers instructions are available on site; the appliance, materials and components are clean, undamaged and dry; sufficient quantities of all components required to complete the installatio
22、n are available, including those not supplied by the appliance manufacturer. Hearths and fireplace recesses shall be checked to ensure that they are finished to the correct dimensions for the insertion of the appliance, special regard being paid to any minimum/maximum sizes quoted in BS 8303 : Part
23、1. NOTE. Some appliances require a special fireplace surround, hearth or both. 5.2 Handling on site The appliance and components shall be handled in a manner such as to prevent breakage and deterioration. Special care shall be taken before, during and after installation to ensure that equipment is n
24、ot damaged. NOTE 1. This is particularly important with fittings that are vitreous enamelled, plated or fitted with glass. Any components removed during transit or storage shall be handled so that they can be identified and refitted correctly to the original equipment. NOTE 2. This is especially imp
25、ortant where several different appliances are stored together as some parts are individually fitted to each appliance by the manufacturer and are not interchangeable. 5.3 Site storage Suitable accomodation offering safe, dry and frost free storage shall be provided for all components, e.g. appliance
26、s, pipes, ducting, fireplace surrounds, firebacks and refractory air-setting cement. All components shall be stored on a firm level base in the original packaging and in accordance with the manufacturers instructions. Where storage is on a solid floor, components shall be stacked on a sheet of polyt
27、hene, pallets or timber to prevent any rising damp affecting them. The appliance instructions and any operating, stoking and cleaning tools shall be kept safely in store until they can be handed directly to the user on completion of the installation. 6 Coordination of work and installation preparati
28、on In preparing for the installation of an appliance liasion shall be established with the contractor, builder or householder to ensure that site access is available, cooperation between trades is arranged and sufficient time is allowed for completing each phase of the installation. Care shall be ta
29、ken to ensure that: a) all accessories and materials for construction are avilable on site; Licensed Copy: London South Bank University, London South Bank University, Fri Dec 08 06:10:40 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 8303 : Part 2 : 1994 4 b) chases are formed true to size and correc
30、tly positioned; c) the fireplace recess, chimney, lintels and flue-connecting blocks are installed in accordance with the design specification in their true relation to the appliance, and hearth; d) the pipework is ready for connection to the boiler as soon as the appliance has been fixed in place;
31、e) any ducts or vents required to be formed in builders work have been laid or constructed; f) the fitters and finishing tradesmens work is coordinated and protection is provided for vulnerable surface finishes, e.g. hearths, floors. NOTE. The final connections between appliance and flue should be c
32、ompleted when the structural and appliance installation work is finished. 7 Installation work on site 7.1 General requirements The instructions of the appliance manufacturer shall be followed in conjunction with the design specification in accordance with of BS 8303 : Part 1. 7.2 Chimney and firepla
33、ce recess construction and preparation Any soot door required for cleaning the chimney shall be correctly located and fitted. (See clause 10 of BS 8303 : Part 1 : 1994). With both new and old chimneys, and before proceeding with appliance installation, a check shall be made to ensure that the flue i
34、s clean, clear of any obstruction, in a sound condition and of adequate size to suit the appliance being installed. 7.3 Appliances with a boiler The boiler shall be coupled to the hot water system by means of unions. Easy access shall be provided for removal. If flow and return pipes are taken throu
35、gh a fireplace recess wall they shall be sleeved for easy removal or replacement. A drain cock shall be fitted at the lowest point in the system for draining down when required. For insert appliances fitted with a boiler it is important that connection of pipework to the boiler and leak testing shal
36、l take place before the space around the appliance is in-filled with insulating material. 7.4 Composition of insulating in-fill Inset open fires and inset roomheaters shall be installed using in-fill material behind firebacks or boilers, and around roomheater casings (see BS 8303 : Part 1 : 1993, fi
37、gures 1, 2, 3, 13 and 15). NOTE. Further information is given in clause 14 of BS 8303 : Part 3 : 1994. 7.5 Gas supply If a gas point is required for connecting to an ignition burner or independent gas poker it shall be installed close to the appliance. NOTE. Attention is drawn to the Gas Safety (Ins
38、tallation and Use) Regulations 3. 7.6 Electric supply If a supply of electricity is necessary to operate the control equipment or initiate ignition in an appliance, the electrical supply shall be installed in accordance with BS 7671 : 1992. The electrical installation shall be in accordance with BS
39、7671. 7.7 Making good Following installation all building works etc. shall be made good. 8 Commissioning of the installation 8.1 Inspection Preferably not less than 48 h after the appliance has been installed, it shall be examined to ensure that all fittings (in particular dampers, boiler flue pipe,
40、 flue adaptor and boiler pipes) are firmly fixed in the correct position and that no gaps allowing possible air or water leakage have appeared. Similarily, air supply intakes and ducts shall be checked for size and position. After installation the appliance shall not be used for burning builders rub
41、bish. 8.2 Testing 8.2.1 Before lighting a fire, any water system connected to the appliance shall be filled. The installation shall be dried out under slow fire conditions preferably for about 2 days using the type and size of fuel recommended in the appliance manufacturers instructions. 8.2.2 The i
42、nstaller shall confirm that the fire responds to the operation of the controls and that there is no visible emission of combustion products to the room. 8.2.3 Appliances incorporating a boiler shall be tested to ensure that the water is circulating throughout the system. NOTE. For further informatio
43、n see clause 15 of BS 8303 : Part 3 : 1994. 9 Handover On completion of installing and commissioning the system, the installer shall hand over the manufacturers operating instructions to the user in order to provide full information regarding the operation and maintenance of the appliance. Licensed
44、Copy: London South Bank University, London South Bank University, Fri Dec 08 06:10:40 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 8303 : Part 2 : 1994 1) Referred to in foreword only. List of references(see clause 2) Normative references BSI publications BRITISH STANDARDS INSTITUTION, London BS 18
45、46 :Glossary of terms relating to solid-fuel burning equipment BS 1846 : Part 1 : 1994Domestic appliances BS 7671 : 1992Requirements for electrical installations BS 8303 :Installationsof domestic heating and cooking appliances burning solid mineral fuels BS 8303 : Part 1 : 1994Specification for the
46、design of installations Informative references BSI publications BRITISH STANDARDS INSTITUTION, London BS 5449 : 1990Specification for circulation hot water central systems for domestic premises1) BS 8303 :Installation of domestic heating and cooking appliances burning solid mineral fuels BS 8303 : P
47、art 3 : 1994Recommendations for design and on-site installation Other references 1GREAT BRITAIN. Building Regulations. London: HMSO1) 2GREAT BRITAIN. Clean Air Act. London: HMSO1) 3GREAT BRITAIN. Gas Safety (Installation and Use) Regulations. London: HMSO Licensed Copy: London South Bank University,
48、 London South Bank University, Fri Dec 08 06:10:40 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BSI 389 Chiswick High Road London W4 4AL | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
49、 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | BSI British Standards Institution BSI is the independent national body responsible for preparing British Standards. It presents the UK view on standards in Europe and at the international level. It is incorporated by Royal Charter. Revisions British Standards are updated by amendment or revision. Users of British Standards should make sure that they possess the latest amendments or editions. It is the constant aim of BSI to improve the quality of our products and service