BS-EN-12424-2000.pdf
《BS-EN-12424-2000.pdf》由会员分享,可在线阅读,更多相关《BS-EN-12424-2000.pdf(8页珍藏版)》请在三一文库上搜索。
1、| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | BRITISH STANDARD BS EN 12424:2000 The Euro
2、pean Standard EN 12424:2000 has the status of a British Standard ICS 91.060.50 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW Industrial,commercial and garage doors and gates Resistance to wind load Classification Licensed Copy: sheffieldun sheffieldun, na, Sat Oct 28 09:17:5
3、3 GMT+00:00 2006, Uncontrolled Copy, (c) BSI This British Standard, having been prepared under the direction of the Sector Committee for Building and Civil Engineering, was published under the authority of the Standards Committee and comes into effect on 15 October 2000 BSI 10-2000 ISBN 0 580 36539
4、5 BS EN 12424:2000 Amendments issued since publication Amd. No.DateComments National foreword This British Standard is the official English language version of EN 12424:2000. The UK participation in its preparation was entrusted by Technical Committee B/538, Doors, windows, shutters, hardware and cu
5、rtain walling, to Subcommittee B/538/5, Industrial, commercial and garage doors and gates, which has the responsibility to: aid enquirers to understand the text; present to the responsible European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests info
6、rmed; monitor related international and European developments and promulgate them in the UK. A list of organizations represented on this subcommittee can be obtained on request to its secretary. Cross-references The British Standards which implement international or European publications referred to
7、 in this document may be found in the BSI Standards Catalogue under the section entitled International Standards Correspondence Index, or by using the Find facility of the BSI Standards Electronic Catalogue. A British Standard does not purport to include all the necessary provisions of a contract. U
8、sers of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 5 and a back cover. The
9、BSI copyright notice displayed in this document indicates when the document was last issued. Licensed Copy: sheffieldun sheffieldun, na, Sat Oct 28 09:17:53 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 12424 July 2000 ICS 91.060.50 English version I
10、ndustrial, commercial and garage doors and gates - Resistance to wind load - Classification Portes quipant les locaux industriels, commerciaux et les garages - Rsistance la charge de vent - Classification Tore - Widerstand gegen Windlast - Klassifizierung This European Standard was approved by CEN o
11、n 19 July 2000. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may
12、be obtained on application to the Central Secretariat or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the Centr
13、al Secretariat has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom
14、. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Central Secretariat: rue de Stassart, 36 B-1050 Brussels 2000 CENAll rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 12424:2000 E Licens
15、ed Copy: sheffieldun sheffieldun, na, Sat Oct 28 09:17:53 GMT+00:00 2006, Uncontrolled Copy, (c) BSI Page 2 EN 12424:2000 Contents Page Foreword2 1Scope2 2Normative References3 3Terms and definitions3 4Classification3 5Marking4 Bibliography5 Foreword This European Standard has been prepared by Techn
16、ical Committee CEN/TC 33 “ Doors, windows, shutters, building hardware and curtain walling“, the secretariat of which is held by AFNOR. This European Standard shall be given the status of a national standard, either by publica- tion of an identical text or by endorsement, at the latest by January 20
17、01, and conflicting national standards shall be withdrawn at the latest by January 2001. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Czech Republic, Denmark, Finlan
18、d, France, Germany, Greece, Iceland, Ireland, Italy, Lux- embourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and the United King- dom. No existing EN standard is superseded. This standard is one of a series of performance standards identified within the product stan- dard prEN 13421:
19、1998. European Standards as well as relevant national regulations and standards will enable the actual exposure levels to be determined for the individual locations of the products. 1 Scope 1.1 General This European Standard specifies the classification for wind load for doors in a closed posi- tion
20、. The doors are intended for installation in areas in the reach of people, for which the main intended uses are giving safe access for goods, vehicles and persons in industrial, commer- cial or residential premises. Licensed Copy: sheffieldun sheffieldun, na, Sat Oct 28 09:17:53 GMT+00:00 2006, Unco
21、ntrolled Copy, (c) BSI Page 3 EN 12424:2000 The doors may be manually or power operated. NOTE In case of wind load it is not necessary that the door can be opened or closed. This document applies to all doors provided in accordance with prEN 13241:1998. 1.2 Exclusions It does not apply to: - lock ga
22、tes and dock gates; - doors on lifts; - doors on vehicles; - armoured doors; - doors mainly for the retention of animals; - theatre textile curtains; - horizontally moving doors less than 2,5 m wide and 6,25 m 2 area, designed principally for pedestrian use; - revolving doors of any size; - doors ou