《BS-EN-15287-2-2008.pdf》由会员分享,可在线阅读,更多相关《BS-EN-15287-2-2008.pdf(91页珍藏版)》请在三一文库上搜索。
1、BS EN 15287-2:2008 Incorporating corrigendum November 2008 Licensed Copy: London South Bank University, South Bank University, 31/01/2009 04:19, Uncontrolled Copy, (c) BSI National foreword This British Standard is the UK implementation of EN 15287-2:2008. The UK participation in its preparation was
2、 entrusted to Technical Committee B/506, Chimneys. National Annex NA (informative) identifi es the provisions currently required to meet the UK devolved administrations Building Regulations for chimneys. A list of organizations represented on this committee can be obtained on request to its secretar
3、y. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard cannot confer immunity from legal obligations. Amendments/corrigenda issued since publication DateComments 0 November 2008
4、Correction to National Foreword, and addition of National Annex NA This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 September 2008 #BSI 2008 ISBN 978 0 580 65257 8 BS EN 15287-2:2008 3 Licensed Copy: London South Bank University, South Bank
5、 University, 31/01/2009 04:19, Uncontrolled Copy, (c) BSI BS EN 15287-2:2008 EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 15287-2 March 2008 ICS 91.060.40 English Version Chimneys - Design, installation and commissioning of chimneys - Part 2: Chimneys for roomsealed appliances Chemines - Con
6、ception, installation et mise en service des conduits de fume - Partie 2 : Conduits de fume pour chaudires tanches Abgasanlagen - Planung, Montage und Abnahme von Abgasanlagen - Teil 2: Abgasanlagen fr raumluftunabhngige Feuersttten This European Standard was approved by CEN on 10 February 2008. CEN
7、 members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on appl
8、ication to the CEN Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre
9、has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland,
10、Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: rue de Stassart, 36 B-1050 Brussels 2008 CENAll rights of exploitation in any form and by any
11、means reserved worldwide for CEN national Members. Ref. No. EN 15287-2:2008: E Licensed Copy: London South Bank University, South Bank University, 31/01/2009 04:19, Uncontrolled Copy, (c) BSI BS EN 15287-2:2008 EN 15287-2:2008 (E) 2 Contents Page Foreword5 1 Scope 6 2 Normative references6 3 Terms a
12、nd definitions .7 4 Design.9 4.1 General9 4.2 Data requirements .9 4.2.1 Sources of data and information9 4.2.2 Heating appliance information.9 4.2.3 Chimney system product specification.10 4.2.4 Building construction and chimney system route information10 4.2.5 Local conditions 13 4.3 Design requir
13、ements.14 4.3.1 General14 4.3.2 Chimney system designation.14 4.3.3 Properties of construction of the chimney.16 4.3.4 Chimney system sizing and characteristics for roomsealed applications19 4.3.5 Chimney system route 19 4.3.6 Connecting flue pipe and connection air supply pipe route.19 4.3.7 Resist
14、ance to fire (external to external) 20 4.3.8 Distance to combustible material (Resistance to fire internal to external) .20 4.3.9 Accidental human contact21 4.3.10 Accidental ignition of extraneous loose material.21 4.3.11 Supports.21 4.3.12 Joints 22 4.3.13 Chimney offset.22 4.3.14 Access for inspe
15、ction, cleaning and measuring22 4.3.15 Distance between openings in the chimney system22 4.3.16 Back ventilation .23 4.3.17 Location of chimney outlet.23 4.3.18 External parts.24 4.3.19 Weatherproofing24 4.3.20 Lightning protection25 4.3.21 Earthing of chimney systems.25 4.3.22 Silencer.25 4.3.23 Co
16、ndensate drainage system.25 4.3.24 Rain cap25 4.3.25 Rainwater disposal26 4.3.26 Terminals26 4.4 Chimney plate and additional information26 5 Installation27 5.1 General27 5.2 Construction of relined or converted chimney systems.27 5.3 Chimney plate 27 6 Commissioning/handover.28 Annex A (normative)
17、Determination of the chimney and connecting flue pipe system designation and essential additional information for custom built, relined and converted chimney systems, for concentric flue/air supply duct configuration29 Licensed Copy: London South Bank University, South Bank University, 31/01/2009 04
18、:19, Uncontrolled Copy, (c) BSI BS EN 15287-2:2008 EN 15287-2:2008 (E) 3 A.1 General .29 A.2 Temperature class.29 A.3 Pressure class .40 A.4 Resistance to condensate class40 A.5 Corrosion resistance class.40 A.6 Sootfire resistance class40 A.7 Distance to combustible material41 A.8 Thermal resistanc
19、e of the flue duct.41 A.9 Coefficient of flow resistance of the flue duct41 A.10 Thermal resistance of the air supply duct41 A.11 Coefficient of flow resistance of the air supply duct.41 Annex B (informative) Information for the heating appliance(s)42 Annex C (informative) Example of system chimney
20、product designation44 Annex D (informative) Correlation between designation parameters for clay/ceramic flue liners and clay/ceramic flue blocks and concrete flue blocks 45 Annex E (informative) Designation of metal system chimneys and correlation between metal liner material designation and corrosi
21、on load in Member States (MS) .47 Annex F (informative) Example of chimney system designation for roomsealed applications .53 Annex G (informative) Example for chimney system plate.54 G.1 Example of a concentric chimney system configuration plate 54 G.2 Example of a separate chimney system configura
22、tion plate54 Annex H (normative) Determination of the chimney designation for a completed metal system chimney55 H.1 General .55 H.2 Corrosion resistance class.55 Annex I (informative) Example of the determination of the designation of a converted/relined chimney system.56 I.1 Input data for a typic
23、al converted/relined chimney .56 I.1.1 Existing chimney.56 I.1.2 Liner56 I.1.3 Insulation56 I.2 Temperature class designation .57 I.2.1 General .57 I.2.2 Material characteristic.57 I.2.3 Fire protection .58 I.2.4 Human contact.59 I.2.5 Determination of temperature class59 I.2.6 Check of mean tempera
24、tures.59 I.3 Pressure class designation61 I.4 Resistance to condensate class designation.61 I.5 Corrosion resistance class designation.61 I.6 Sootfire resistance class61 I.7 Distance to combustible material61 I.8 Designation of the converted/relined chimney 62 I.9 Chimney plate of the converted/reli
25、ned chimney in this annex.62 Annex J (informative) Example for the determination of the designation of a custom built chimney system.63 J.1 Input data for a custom-built chimney system.63 J.1.1 Liner63 J.1.2 Insulation63 J.1.3 Air supply duct 63 J.1.4 Combustible wall.63 J.2 Temperature class design
26、ation .64 J.2.1 General .64 J.2.2 Material characteristic.64 Licensed Copy: London South Bank University, South Bank University, 31/01/2009 04:19, Uncontrolled Copy, (c) BSI BS EN 15287-2:2008 EN 15287-2:2008 (E) 4 J.2.3 Resistance to fire.64 J.2.4 Human contact.66 J.2.5 Determination of temperature
27、 class 66 J.2.6 Check of mean temperatures .66 J.3 Pressure class designation68 J.4 Resistance to condensate class designation.68 J.5 Corrosion resistance class designation .68 J.6 Sootfire resistance class 68 J.7 Distance to combustible material 68 J.8 Designation of the custom-built chimney.69 J.9
28、 Chimney plate for the custom-built chimney in this annex 69 Annex K (informative) Location of outlets of chimney systems 70 Annex L (informative) Method for calculating the temperature of adjacent materials.74 L.1 Method for the calculation of the temperature of adjacent materials74 L.2 Example for
29、 calculation of the temperature of adjacent materials.76 Annex M (informative) Checking, handling and site storage of materials and components 78 M.1 General78 M.2 Checking, handling and site storage of materials and components78 M.2.1 Checking on delivery of materials .78 M.2.2 Checking before inst
30、allation.78 M.2.3 Check of existing chimney .78 M.2.4 Site handling and storage.78 M.2.5 Coordination of work.79 Annex N (informative) Chimney commissioning80 N.1 General80 N.2 Physical checks.80 N.3 Operational checks81 N.3.1 Flue flow test81 N.3.2 Smoke test81 N.3.3 Gas tightness test82 Method B:
31、O2 measurement in concentric air supply ducts for gas .82 Annex O (informative) Recommendations for inspection, cleaning and maintenance84 O.1 General84 O.2 Inspection and cleaning84 O.3 Maintenance.84 Bibliography85 Licensed Copy: London South Bank University, South Bank University, 31/01/2009 04:1
32、9, Uncontrolled Copy, (c) BSI BS EN 15287-2:2008 EN 15287-2:2008 (E) 5 Foreword This document (EN 15287-2:2008) has been prepared by Technical Committee CEN/TC 166 “Chimneys”, the secretariat of which is held by UNI. This European Standard shall be given the status of a national standard, either by
33、publication of an identical text or by endorsement, at the latest by September 2008, and conflicting national standards shall be withdrawn at the latest by September 2008. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or
34、 CENELEC shall not be held responsible for identifying any or all such patent rights. This European Standard is one of a series of specifications as listed below. Chimneys Design, installation and commissioning of chimneys Part 1: Chimneys for non-roomsealed heating appliances. Chimneys Design, inst
35、allation and commissioning of chimneys Part 2: Chimneys systems for roomsealed appliances. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Repub
36、lic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. Licensed Copy: London South Bank University, South Bank
37、University, 31/01/2009 04:19, Uncontrolled Copy, (c) BSI BS EN 15287-2:2008 EN 15287-2:2008 (E) 6 1 Scope This European Standard describes the method of specifying the design, installation and labelling criteria for chimney systems, connecting flue pipes and air supply pipes for roomsealed heating a
38、pplications. It also gives information on commissioning of an installed chimney. This standard does not cover: chimneys designated H (high positive pressure chimneys), and chimneys designated P (normal positive pressure chimneys) serving more than one appliance, chimneys which serve a mixture of fan
39、 assisted or forced draught burners or natural draught appliances, installations having a configuration of the type C2. This European Standard does not apply to freestanding chimneys covered by EN 13084-1. This standard also specifies limitations for supporting a chimney, and the maximum unsupported
40、 chimney height for system chimneys and custom built chimneys. NOTE Roomsealed gas appliances are classified as type C according to CEN/TR 1749. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition ci
41、ted applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 771-1, Specification for masonry units - Part 1: Clay masonry units EN 771-2, Specification for masonry units - Part 2: Calcium silicate masonry units EN 1443: 2003, Chimneys Gen
42、eral requirements EN 1457, Chimneys Clay/ceramic flue liners Requirements and test methods EN 1806, Chimneys Clay/ceramic flue blocks for single wall chimneys - Requirements and test methods EN 1856-1, Chimneys Requirements for metal chimneys Part 1: System chimney products EN 1856-2, Chimneys Requi
43、rements for metal chimneys Part 2: Metal liners and connecting flue pipes EN 1857, Chimneys Components Concrete flue liners EN 1858, Chimneys Components Concrete flue blocks EN 1993-3-2, Eurocode 3: Design of steel structures Part 3-2: Towers, masts and chimneys Chimneys EN 12446, Chimneys Component
44、s Concrete outer wall elements EN 13063, Chimneys System chimneys with clay/ceramic flue liners Part 1: Requirements and test methods for sootfire resistance EN 13063-2, Chimneys System chimneys with clay/ceramic flue liners Part 2: Requirements and test methods under wet conditions Licensed Copy: L
45、ondon South Bank University, South Bank University, 31/01/2009 04:19, Uncontrolled Copy, (c) BSI BS EN 15287-2:2008 EN 15287-2:2008 (E) 7 EN 13063-3, Chimneys - System chimneys with clay/ceramic flue liners - Part 3: Requirements and test methods for air flue system chimneys EN 13069, Chimneys Clay/
46、ceramic outer walls for system chimneys Requirements and test methods EN 13084-1, Free-standing chimneys Part 1: General requirements EN 13384-1: 2002, Chimneys Thermal and fluid dynamic calculation methods Part 1: Chimneys serving one appliance EN 13384-2, Chimneys Thermal and fluid dynamic calcula
47、tion methods Part 2: Chimneys serving more than one heating appliance EN 13502, Chimneys - Requirements and test methods for clay/ceramic flue terminals EN 14471, Chimneys - System chimneys with plastic flue liners - Requirements and test methods EN 14989-1, Chimneys - Requirements and test methods
48、for metal chimneys and material independent air supply ducts for roomsealed heating applications - Part 1: Vertical air/flue terminals for C6-type appliances EN 14989-2, Chimneys - Requirements and test methods for metal chimneys and material independent air supply ducts for roomsealed heating appli
49、cations - Part 2: Flue and air supply ducts for room sealed appliances EN 15287-1:2007, Chimneys - Design, installation and commissioning of chimneys - Part 1: Chimneys for non-roomsealed heating appliances 3 Terms and definitions For the purposes of this document, the terms and definitions given in EN 1443:2003, EN 15287-1:2007 and the following apply. NOTE 1 Examples of balanced air/flue configurations for roomsealed applications are given in Figures 1 and 2. The configurations of Figure 1 and Figure 2 m
链接地址:https://www.31doc.com/p-3738785.html