1、BRITISH STANDARD BS EN 13502:2002 Chimneys Requirements and test methods for clay/ceramic flue terminals The European Standard EN 13502:2002 has the status of a British Standard ICS 91.060.40 ? Licensed Copy: sheffieldun sheffieldun, na, Mon Oct 30 06:22:55 GMT+00:00 2006, Uncontrolled Copy, (c) BSI
2、 BS EN 13502:2002 This British Standard, having been prepared under the direction of the Building and Civil Engineering Sector Policy and Strategy Committee, was published under the authority of the Standards Policy and Strategy Committee on 31 October 2002 BSI 31 October 2002 ISBN 0 580 40681 4 Nat
3、ional foreword This British Standard is the official English language version of EN 13502:2002. EN 13502:2002 is a candidate “harmonized” European Standard and fully takes into account the requirements of the European Commission mandate M105, Chimneys, given under the EU Construction Products Direct
4、ive (89/106/EEC), and is intended to lead to CE marking. The date of applicability of EN 13502:2002 as a “harmonized” European Standard, i.e. the date after which this standard may be used for CE marking purposes, is subject to an announcement in the Official Journal of the European Communities. EN
5、13502:2002 is the subject of transitional arrangements agreed under the European Commission mandate. The Member States have agreed a nominal transition period for the co-existence of EN 13502:2002 and their corresponding national standard(s). It is intended that this period will comprise a nominal n
6、ine month period during which any required changes to national regulations are to be made, followed by a further nominal twelve month period for the implementation of CE marking. At the end of this co-existence period, the national standard(s) will be withdrawn. In the UK, the corresponding national
7、 standard is: BS 1181:1999, Specification for clay flue terminals; and based on this transition period of twenty-one months, BS 1181:1999 would be withdrawn in July 2004 NOTE This date is approximate. Users of this standard should contact BSI Customer Services for confirmation of withdrawal. The UK
8、participation in its preparation was entrusted by Technical Committee B/506, Chimneys, to Subcommittee B/506/3, Chimneys and their components having inner linings of clay/ceramic, which has the responsibility to: A list of organizations represented on this subcommittee can be obtained on request to
9、its secretary. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electron
10、ic Catalogue or of British Standards Online. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to unde
11、rstand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. Summary of pages This document compris
12、es a front cover, an inside front cover, the EN title page, pages 2 to 25 and a back cover. The BSI copyright date displayed in this document indicates when the document was last issued. Amendments issued since publication Amd. No. DateComments Licensed Copy: sheffieldun sheffieldun, na, Mon Oct 30
13、06:22:55 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 13502 October 2002 ICS 91.060.40 English version Chimneys - Requirements and test methods for clay/ceramic flue terminals Conduits de fume - Terminaux en terre cuite/cramique - Prescriptions et m
14、thodes dessai Abgasanlagen - Anforderungen und Prfverfahren fr Keramik-Aufstze This European Standard was approved by CEN on 31 August 2002. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a nati
15、onal standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any
16、other language made by translation under the responsibility of a CEN member into its own language and notified to the Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany,
17、Greece, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: rue de Stassart, 36 B-1050 Brussels 2002 CENAll ri
18、ghts of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 13502:2002 E Licensed Copy: sheffieldun sheffieldun, na, Mon Oct 30 06:22:55 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 13502:2002 (E) 2 Contents page Foreword 3 1Scope 4 2Normative referenc
19、es 4 3Terms and Definitions. 4 4Product shape 6 5Materials . 6 6Tolerances on dimensions . 6 6.1Size 6 6.2Height 6 6.3Squareness of base end of parallel sided flue terminals 6 7Acid resistance 6 8Freeze/ thaw resistance 6 9Flow resistance 7 10Aerodynamic behaviour 7 10.1General 7 10.2Ridge terminals
20、 7 10.3Type 0 restricted flue terminals 7 10.4Type 1 restricted flue terminals 7 10.4Type 2 restricted flue terminals 7 11Evaluation of conformity. 7 11.1Initial type testing 7 11.2Further type tests 7 11.3Factory production control. 8 12Test methods . 8 12.1Internal transverse dimensions 8 12.2Heig
21、ht 8 12.3Squareness of base end of parallel sided flue terminals 9 12.4Acid resistance 9 12.5Freeze/thaw 11 12.6Flow resistance 12 12.7Aerodynamic behaviour for Type 1 restricted flue terminals . 13 12.8Aerodynamic behaviour for Type 2 restricted flue and ridge terminals 13 13Designation 16 14Markin
22、g. 17 Annex A (normative) Sampling procedures for an AQL of 10 % and Inspection Level S2 . 18 Annex ZA (informative) Clauses of this European standard addressing the provisions of the EU Construction Products Directive. 22 Licensed Copy: sheffieldun sheffieldun, na, Mon Oct 30 06:22:55 GMT+00:00 200
23、6, Uncontrolled Copy, (c) BSI EN 13502:2002 (E) 3 Foreword This document EN 13502:2002 has been prepared by Technical Committee CEN/TC 166 “Chimneys”, the secretariat of which is held by UNI. This European Standard shall be given the status of a national standard, either by publication of an identic
24、al text or by endorsement, at the latest by April 2003, and conflicting national standards shall be withdrawn at the latest by July 2004. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association and supports essential requirement
25、s of EU Directive(s). For relationship with EU directives, see informative annex ZA which is an integral part of this document. Annex A is normative. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this Europea
26、n Standard: Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and the United Kingdom. Licensed Copy: sheffieldun sheffieldun, na, Mon Oct 30 06:22:55 GMT+00:00 2006, Uncon
27、trolled Copy, (c) BSI EN 13502:2002 (E) 4 1 Scope This European Standard specifies requirements and test methods for clay/ceramic flue terminals with solid walls, which serve to convey the products of combustion from the flue to the atmosphere by negative pressure. It includes terminals used on dome
28、stic and industrial chimneys which are not structurally independent (free standing). This standard specifies the performance requirements for factory made terminals. Marking and inspection are also covered by this standard. 2 Normative references This European Standard incorporates by dated or undat
29、ed reference, provisions from other publications. These normative references are cited at the appropriate places in the text, and the publications are listed hereafter. For dated references, subsequent amendments to or revisions of any of these publications apply to this European Standard only when
30、incorporated in it by amendment or revision. For undated references the latest edition of the publication referred to applies (including amendments). EN 1443, Chimneys General requirements. ISO 2859-1, Sampling procedures for inspection by attributes - Part 1: Sampling schemes indexed by acceptance
31、quality limit (AQL) for lot-by-lot inspection. 3 Terms and Definitions For the purposes of this European Standard, the terms and definitions given in EN 1443 and the following apply. 3.1 nominal size (DN) numerical designation of size of the base of flue terminals which is a convenient round number
32、equal to or approximately equal to either: a) the internal diameter in millimetres of circular flue terminals; b) the internal width in millimetres of square or octagonal flue terminals when measured between opposite parallel sides; c) the internal width and breadth in millimetres of the cross secti
33、on of rectangular flue terminals. 3.2 nominal height numerical designation of the height in millimetres of a flue terminal which is a convenient round number approximately equal to the overall height of the flue terminal including any decoration 3.3 open-topped terminal terminal designed for fitting
34、 directly to the outlet of an open flue system (see Figure 1) or covered terminal with outlets twice the cross-sectional area of the outlet flue. The hydraulic diameter remains constant throughout the height of the terminal Licensed Copy: sheffieldun sheffieldun, na, Mon Oct 30 06:22:55 GMT+00:00 20
35、06, Uncontrolled Copy, (c) BSI EN 13502:2002 (E) 5 Figure 1 Examples of open-topped flue terminals 3.4 ridge terminal restricted terminal designed for fitting at the ridge of a building (see Figure 2). NOTERidge terminals are used only with gas appliances. Figure 2 Example of ridge terminal 3.5 rest
36、ricted flue terminal terminal designed with outlets having a total opening area less than twice the cross-sectional area of the outlet flue (see Figure 3) Figure 3 Examples of restricted flue terminals Licensed Copy: sheffieldun sheffieldun, na, Mon Oct 30 06:22:55 GMT+00:00 2006, Uncontrolled Copy,
37、 (c) BSI EN 13502:2002 (E) 6 4 Product shape Flue terminals shall be parallel sided or tapered with outlets not specified but adequate to disperse products of combustion and have a base end which shall be either: a)circular in cross-section with or without parallel ends; or b)square, rectangular or
38、octagonal in cross-section with rounded internal and external corners and with or without parallel ends. 5 Materials Flue terminals shall be manufactured from suitable clay/ceramic material which when fired meet the performance requirements given in this standard. Flue terminals shall be unglazed or
39、 glazed on the interior and/or exterior. When glazed, they need not be glazed on the jointing surfaces. 6 Tolerances on dimensions 6.1 Size When tested in accordance with 12.1, the internal diameter of circular flue terminals measured on any diameter shall not deviate by more than 5 % of the manufac
40、turers stated nominal internal diameter. The internal length of a side of square, rectangular or octagonal section flue terminals shall not deviate by more than 5 % of the manufacturers stated nominal internal length of the side. 6.2 Height When tested in accordance with 12.2, the height of flue ter
41、minals shall not deviate more than -2 % +5 % of the manufacturers stated nominal height. 6.3 Squareness of base end of parallel sided flue terminals When tested in accordance with 12.3, the permissible deviation from square of the base end of flue terminals shall be not greater than an angle of slop
42、e 30 mm/m. 7 Acid resistance When tested in accordance with 12.4, the mass loss from any test piece shall not exceed 5,0 %. 8 Freeze/ thaw resistance The manufacturer shall declare the freeze-thaw resistance of his product expressed in terms of lamination, cracking or flaking. When tested in accorda
43、nce with 12.5.2 (Spray test), a terminal shall pass the test if significant lamination, cracking or flaking has not occurred. Licensed Copy: sheffieldun sheffieldun, na, Mon Oct 30 06:22:55 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 13502:2002 (E) 7 9 Flow resistance The manufacturer shall declar
44、e the flow resistance of his product expressed as flow resistance factor. When tested in accordance with 12.6, a flue terminal shall have a flow resistance factor not greater than the manufacturers declared flow resistance factor value. 10 Aerodynamic behaviour 10.1 General The smallest dimension of
45、 any opening in a restricted flue terminal shall be greater than 10 mm. 10.2 Ridge terminals When tested in accordance with 12.8 ridge terminals shall have a resistance factor, K, not greater than 15. 10.3 Type 0 restricted flue terminals Type 0 restricted flue terminals shall not be tested for aero
46、dynamic behaviour. 10.4 Type 1 restricted flue terminals When tested in accordance with 12.7 with a wind pressure angles between +90 and 45, Type 1 restricted flue terminals shall have a static pressure not greater than: - PR = 0,2 x Vw2 x Pa where PRis the manufacturers declared pressure difference
47、 in Pascals (Pa) between flue terminal and the test room at an internal flow velocity of 2 m/s Vwis the wind speed in metres per second (m/s) For negative pressure chimneys the maximum value of ?PR shall be 2 Pa. 10.5 Type 2 restricted flue terminals When tested in accordance with 12.8, Type 2 restr
48、icted flue terminals shall have a resistance factor, K, not greater than 5. 11 Evaluation of conformity 11.1 Initial type testing Type tests for the required characteristics given in Table 1 shall be performed at the beginning of the production. One test shall be carried for each requirement. 11.2 F
49、urther type tests Type tests shall be performed also when a change is made either in material composition, processing technique or to the design or method of manufacture of the flue terminal (see Table 1). Licensed Copy: sheffieldun sheffieldun, na, Mon Oct 30 06:22:55 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 13502:2002 (E) 8 NOTE These tests can be performed more frequently by incorporation into a plan for monitoring the consistency of manufacture. Table 1 Factory produ