《BS-EN-12045-2000.pdf》由会员分享,可在线阅读,更多相关《BS-EN-12045-2000.pdf(12页珍藏版)》请在三一文库上搜索。
1、| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | BRITISH STANDARD BS EN 12045:2000 The Euro
2、pean Standard EN 12045:2000 has the status of a British Standard ICS 91.060.50 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW Shutters and blinds power operated Safety in use Measurement of the transmitted force Licensed Copy: sheffieldun sheffieldun, na, Sat Oct 28 16:30:34
3、GMT+00:00 2006, Uncontrolled Copy, (c) BSI This British Standard, having been prepared under the direction of the Sector Committee for Building and Civil Engineering, was published under the authority of the Standards Committee and comes into effect on 15 August 2000 BSI 08-2000 ISBN 0 580 34027 9 B
4、S EN 12045:2000 Amendments issued since publication Amd. No.DateComments National foreword This British Standard is the official English language version of EN 12045:2000. The UK participation in its preparation was entrusted by Technical Committee B/538, Doors, windows, shutters, hardware and curta
5、in walling, to Subcommittee B/538/3, Domestic shutters and blinds, which has the responsibility to: aid enquirers to understand the text; present to the responsible European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related in
6、ternational and European developments and promulgate them in the UK. A list of organizations represented on this subcommittee can be obtained on request to its secretary. Cross-references The British Standards which implement international or European publications referred to in this document may be
7、 found in the BSI Standards Catalogue under the section entitled International Standards Correspondence Index, or by using the Find facility of the BSI Standards Electronic Catalogue. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standard
8、s are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 8, an inside back cover and a back cover. The BS
9、I copyright notice displayed in this document indicates when the document was last issued. Licensed Copy: sheffieldun sheffieldun, na, Sat Oct 28 16:30:34 GMT+00:00 2006, Uncontrolled Copy, (c) BSI (8523($1?67$1$5 1250(?(8523e(11( (8523b,6 - the movement occurring in the course of travel can be cont
10、rolled by the user activating the control device (stopping, starting, reversing). Licensed Copy: sheffieldun sheffieldun, na, Sat Oct 28 16:30:34 GMT+00:00 2006, Uncontrolled Copy, (c) BSI Page 4 EN 12045:2000 %6,? 3.4 automatic operation powered operation when the control device is such that one of
11、 the movements is outside the control of the user (setting in motion extension or retraction, or stopping, starting or reversing) NOTE An automatic operation relating to extension, whereby, e.g., when setting in motion, the user cannot stop the movement during the travel. The operation can be automa
12、tic for the whole cycle. In this case, there is no possibility for the user to stop the movement in either direction, once the operation has been commenced. 3.5 transmitted force the static force (F) exercised by the edge of the curtain, the bottom rail or front profile on a fixed obstacle during ex
13、tension. Figures 1 to 4 illustrate directions of the transmitted forces 3.6 shutter with accumulating or retractable laths shutter for which the transmitted force against an obstacle results due to the progressive accumulation of the weight of the slats 3.7 accumulation condition the curtain being p
14、laced at 0,16 m from its fully extended position, a static force of 150 N applied to the bottom of the curtain in the direction of retraction shall cause a minimum displacement of 0,04 m 3.8 crushing area area likely to occur in the last 0,40 m travel of the curtain, when the transmitted force is ?
15、150 N. In the case of awnings which project, the crushing zone exists if, the awning being in the fully extended position, a fixed obstacle is located less than 0,40 m from the front profile, this being situated at less than 1,80 m head height (see Figures 1 to 4) ) ?P %RWWRP UDLO ?P ) ?P ) Figure 1
16、 Crushing area Direction of transmitted force Roller shutter Figure 2 Crushing area Direction of transmitted force Sliding panel shutter (1 or 2 leaves) Licensed Copy: sheffieldun sheffieldun, na, Sat Oct 28 16:30:34 GMT+00:00 2006, Uncontrolled Copy, (c) BSI Page 5 EN 12045:2000 %6,? ? ?P? ?P? Figu
17、re 3 Crushing area Direction of the transmitted force Wing shutter =?P G?P ) )?1 Figure 4 Crushing area Direction of transmitted force Folding arms awning 3.9 shearing area (Case of conservatory awning) area likely to occur over each fixed idling roller, by the passage of the front profile, assuming
18、 the following conditions exist simultaneously: ?The transmitted force of the front profile exceeds or is equal to 150 N; ?The front profile is lower than 1,80 m, head height; ?The distance between the front profile and the fixed roller or any associated fixed obstacle, is 0,07 m. See Figure 5. Figu
19、re 5 Conservatory awning Shearing area above each roller created by the passage of the front profile )URQW?SURILOH 5ROOHU H = =H?P DQG )?1 DQG =?P 6KHDULQJ?DUHD ) Licensed Copy: sheffieldun sheffieldun, na, Sat Oct 28 16:30:34 GMT+00:00 2006, Uncontrolled Copy, (c) BSI Page 6 EN 12045:2000 %6,? 4Mea
20、surement of transmitted force 4.1Shutters with accumulating or retractable laths Verification of the accumulation condition Test aim: to measure - the speed of extension of curtain, in the last 0,40 m; - the displacement of the bottom rail in the direction of retraction under the action of a static
21、force of 150 N. Dimensions: the test is carried out for a height and width of product given by the manufacturer. If the accumulating condition occurs, it will be satisfied for all greater heights and smaller widths. Test preparation: the product is provided for the test in a rigid frame and mounted
22、according to the installation instructions of the manufacturer. It is presented vertically and extended up to a distance of 0,16 m from the fully extended position. Test: a load of 150 N shall be applied to the middle of the bottom rail or at mid-height of the leading edge of the curtain in the dire
23、ction of retraction. The displacement obtained shall be recorded. The average speed of extension of the curtain shall be measured in the last 0,40 m. Figure 6 illustrates an example of a test device in the case of a roller shutter. ?P /? G?P ?1 ?1 Figure 6 Accumulating test for the laths Roller shut
24、ter 4.2Roller, sliding shutters, external venetian blinds, flat-closing concertina shutters Test aim: measurement of the transmitted force, when the accumulating condition is not satisfied. Dimensions: for a given motor, the test is carried out for the minimum dimensions specified by the manufacture