《BS-EN-130300-1998.pdf》由会员分享,可在线阅读,更多相关《BS-EN-130300-1998.pdf(36页珍藏版)》请在三一文库上搜索。
1、BRITISH STANDARD BS EN 130300:1998 Harmonized system of quality assessment for electronic components Sectional specification: Aluminium electrolytic capacitors with solid and non-solid electrolyte The European Standard EN 130300:1998 has the status of a British Standard ICS 31.060.50 Licensed Copy:
2、sheffieldun sheffieldun, na, Sun Oct 29 10:18:23 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS EN 130300:1998 This British Standard, having been prepared under the direction of the Electrotechnical Sector Board, was published under the authority of the Standards Board and comes into effect on 15 Jul
3、y 1998 BSI 11-1999 ISBN 0 580 30036 6 National foreword This British Standard is the English language version of EN 130300:1998 published by the European Electronic Components Committee (CECC) of the European Committee for Electrotechnical Standardization (CENELEC). It supersedes BS CECC 30300:1992
4、which will be withdrawn on 1998-10-01. The UK participation in its preparation was entrusted by Technical Committee EPL/40, Capacitors and resistors for electronic equipment, to Subcommittee EPL/40/1, Capacitors and EMI suppression components for electronic equipment, which has the responsibility to
5、: aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep UK interests informed; monitor related international and European developments and promulgate them in the UK. A list of organizat
6、ions represented on this subcommittee can be obtained on request to its secretary. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Standards Catalogue under the section entitled “International Standard
7、s Correspondence Index”, or by using the “Find” facility of the BSI Standards Electronic Catalogue. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard
8、does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, the EN title page, pages 2 to 31 and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. T
9、his will be indicated in the amendment table on the inside front cover. Amendments issued since publication Amd. No.DateComments Licensed Copy: sheffieldun sheffieldun, na, Sun Oct 29 10:18:23 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS EN 130300:1998 BSI 11-1999i Contents Page National forewordIn
10、side front cover Foreword2 Text of EN 1303005 Licensed Copy: sheffieldun sheffieldun, na, Sun Oct 29 10:18:23 GMT+00:00 2006, Uncontrolled Copy, (c) BSI ii blank Licensed Copy: sheffieldun sheffieldun, na, Sun Oct 29 10:18:23 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EUROPEAN STANDARD NORME EUROPEN
11、NE EUROPISCHE NORM EN 130300 March 1998 Supersedes CECC 30300:1988 and its amendments English version Sectional Specification: Aluminium electrolytic capacitors with solid and non-solid electrolyte Spcification intermdiaire: Condensateurs lectrolytiques laluminium lectrolyte solide et non solide Rah
12、menspezifikation: Aluminium-Elektrolyt-Kondensatoren mit festem und flssigem Elektrolyten This European Standard was approved by CENELEC on 1996-07-02. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the s
13、tatus of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, Germa
14、n). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Rep
15、ublic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom. CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr
16、Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B-1050 Brussels 1998 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 130300:1998 E Licensed Copy: sheffieldun sheffieldun, na, Sun Oct 29 10:18:23 GMT+00:00 2006, Un
17、controlled Copy, (c) BSI EN 130300:1998 BSI 11-1999 2 Foreword At the request of CLC/TC CECC/SC 40XA (former WG 3), the text of CECC 30300:1988, Issue 2, with its amendments A1 through A4 and documents CECC(Secretariat)3061 and 3062, was submitted to the formal vote for conversion into a European St
18、andard. The text of the draft, together with the voting report, circulated as document CECC(Secretariat)3205, was approved as EN 130300 on 1992-10-14. The text of document CECC(Secretariat)3451 was submitted to the formal vote and, together with the voting report, circulated as document CECC(Secreta
19、riat)3551, was approved as an amendment to EN 130300 on 1994-05-15. The texts of documents CECC(Secretariat)3499 and 3501 were submitted to the formal vote; together with the voting reports, circulated as documents CECC(Secretariat)3599 and 3600, they were approved as amendments to EN 130300 on 1994
20、-08-22. Two draft amendments were submitted to the formal vote in November 1995 and were approved by CENELEC as amendments to EN 130300 on 1996-07-02. All the above amendments have been incorporated in this European Standard. The following dates were fixed: Contents Page Foreword2 1General5 1.1Scope
21、5 1.2Related documents5 1.3Information to be given in a detail specification5 1.4Terminology6 1.5Marking6 2Preferred ratings and characteristics6 2.1Preferred climatic categories6 2.2Preferred values of ratings6 3Quality assessment procedures7 3.1Primary stage of manufacture7 3.2Structurally similar
22、 components7 3.3Certified test records of released lots7 3.4Qualification approval7 3.5Quality conformance inspection8 4Test and measurement procedures8 4.1Preconditioning8 4.2Visual examination and check of dimensions9 4.3Electrical tests9 4.4Robustness of terminations11 4.5Resistance to soldering
23、heat11 4.6Solderability11 4.7Rapid change of temperature11 4.8Vibration11 4.9Bump12 4.10 Shock12 4.11 Climatic sequence12 4.12 Damp heat, steady state13 4.13 Endurance13 4.14 Surge13 4.15 Reverse voltage13 4.16 Pressure relief14 4.17 Storage at high temperature14 4.18 Storage at low temperature14 4.
24、19 Characteristics at high and low temperatures14 4.20 Charge and discharge or inrush current14 4.21 Component solvent resistance15 4.22 Solvent resistance of the marking15 4.23 High surge current test15 4.24 Voltage transient overload15 latest date by which the EN has to be implemented at national
25、level by publication of an identical national standard or by endorsement(dop) 1998-10-01 latest date by which the national standards conflicting with the EN have to be withdrawn(dow) 1998-10-01 Licensed Copy: sheffieldun sheffieldun, na, Sun Oct 29 10:18:23 GMT+00:00 2006, Uncontrolled Copy, (c) BSI
26、 EN 130300:1998 BSI 11-19993 Page Annex A1 List of tests and sampling plan for qualification approval, assessment level E16 Annex A2 List of tests conformance (lot-by-lot) inspection, assessment level E17 Annex A3 List of tests conformance (periodic) inspection, assessment level E18 Annex B1 List of
27、 tests and sampling plan for qualification approval, assessment level EZ19 Annex B2 List of tests conformance (lot-by-lot) inspection, assessment level EZ20 Annex B3 List of tests conformance (periodic) inspection, assessment level EZ21 Annex C Test schedule for qualification approval, assessment le
28、vels E and EZ22 Table 19 Table 211 Table 312 Table 412 Licensed Copy: sheffieldun sheffieldun, na, Sun Oct 29 10:18:23 GMT+00:00 2006, Uncontrolled Copy, (c) BSI 4 blank Licensed Copy: sheffieldun sheffieldun, na, Sun Oct 29 10:18:23 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 130300:1998 BSI 11-1
29、9995 1 General 1.1 Scope This specification applies to aluminium electrolytic capacitors with solid or non-solid electrolyte primarlily intended for d.c. applications for use in electronic equipment. SMD capacitors are not covered. The object of this specification is to prescribe preferred ratings a
30、nd characteristics and to select from the generic specification EN 130000 the appropriate quality assessment procedures, tests and measuring methods and to give general performance requirements for this type of capacitor. 1.2 Related documents ISO 3, Preferred numbers Series of preferred numbers. IE
31、C 62, Marking codes for resistors and capacitors. IEC 63, Preferred number series for resistors and capacitors. Amendment 1 (1967) Amendment 2 (1977) IEC 68, Basic environmental testing procedures. IEC 384-4, Sectional specification: Aluminium electrolytic capacitors with solid or non-solid electrol
32、yte. IEC 410, Sampling plans and procedures for inspection by attributes. EN 130000, Generic specification: Fixed capacitors. NOTEThe above references apply to the current editions, except for IEC 68, for which the referenced edition must be used. 1.3 Information to be given in a detail specificatio
33、n Detail specifications shall be derived from the relevant blank detail specification. Detail specifications shall not specify requirements inferior to those of the generic, sectional or blank detail specification. When more severe requirements are included, they shall be listed in 1.9 of the detail
34、 specification and indicated in the test schedules, for example by an asterisk. The following information shall be given in each detail specification and the values quoted shall preferably be selected from those given in the appropriate clause of this sectional specification. 1.3.1 Dimensions and ou
35、tline drawing The detail specification shall give an illustration of the capacitor as an aid to easy recognition and for comparison of the capacitor with others. Dimensions and their associated tolerances, which affect interchangeability and mounting, shall be given. All dimensions shall be stated i
36、n mm. NOTEThe information may be presented in tabular form. Normally the numerical values shall be given for the length, the width and height of the body and the wire spacing or for cylindrical types the body diameter, and the length and diameter of the terminations. When necessary, for example when
37、 a number of case sizes are covered by a detail specification, the dimensions and their associated tolerances shall be placed in a table below the drawing. When the configuration is other than described above, the detail specification shall state such dimensional information as will adequately descr
38、ibe the capacitor. When the capacitor is not designed for use on printed boards, this shall be clearly stated in the detail specification. 1.3.2 Mounting The detail specification shall specify the method of mounting to be applied for the application of the vibration and the bump or shock tests. The
39、design of the capacitor may be such that special mounting fixtures are required in its use. In this case the detail specification shall describe the mounting fixtures and they shall be used in the application of the vibration and bump or shock tests. NOTEIf recommendations for mounting for “normal”
40、use are made, they shall be included in the detail specification under 1.8 “Additional information (not for inspection purposes)”. If they are included, a warning can be given that the full vibration, bump and shock performance may not be available if mounting methods other than those specified in 1
41、.1 of the detail specification are used. 1.3.3 Ratings and characteristics The ratings and characteristics shall be in accordance with the relevant clauses of this specification, together with the following: 1.3.3.1 Rated capacitance range See 2.2.1. NOTEWhen products approved to the detail specific
42、ation have different ranges, the following statement should be added: “The range of capacitance values available in each voltage range is given in the Qualified Products List (QPL)”. 1.3.3.2 Particular characteristics Additional characteristics may be listed, when they are considered necessary to sp
43、ecify adequately the component for design and application purposes. Licensed Copy: sheffieldun sheffieldun, na, Sun Oct 29 10:18:23 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 130300:1998 6 BSI 11-1999 1.3.3.3 Soldering The detail specification shall prescribe the test methods, severities and requ
44、irements applicable for the solderability test and the resistance to soldering heat test. 1.3.4 Marking The detail specification shall specify the content of the marking on the capacitor and on the package. Deviations from 1.5 of this sectional specification shall be specifically stated. 1.4 Termino
45、logy In addition to the applicable terms and definitions of EN 130000 the following definitions apply: 1.4.1 capacitance of an electrolytic capacitor the capacitance of an equivalent circuit having capacitance and resistance in series measured with alternating current of approximately sinusoidal wav
46、e form of the specified frequency 1.4.2 rated voltage (UR) the maximum d.c. voltage which may be applied continuously to the terminations of a capacitor at the rated temperature NOTEThe sum of the d.c. voltage and the peak alternating voltage applied to the capacitor shall not exceed the rated volta
47、ge. 1.4.4 reverse voltage (for polar capacitors only) see 2.2.22 of EN 130000 1.5 Marking See 2.4 of EN 130000 with the following details: 1.5.1 The information given in the marking is normally selected from the following list; the relative importance of each item is indicated by its position in the
48、 list: 1) Rated capacitance 2) Rated voltage; (d.c. voltage may be indicated by the symbol or ) 3) Polarity of the terminations: For multi-section capacitors, the rated capacitance and rated voltage of the sections connected to each terminations shall be shown in an unambiguous way. The termination
49、of a capacitor section which is intended for direct connection to the rectifier (so called reservoir section) shall be marked with the number 1 or with the colour red. Bipolar capacitors shall be marked positive at both ends and, if space permits, in addition with the letters “BP”. 4) Tolerance on rated capacitance 5) Year and month (or week) of manufacture 6) Manufacturers name or trade mark 7) Indication of the sub-family (for example 1, 2 or 3) 8) Climatic category 9) Manufacturers type designation 10) Reference to the detail specification. 11
链接地址:https://www.31doc.com/p-3739488.html