1、BRITISH STANDARD BS EN 1647:1999 Incorporating Amendment Nos. 1 and 2 Leisure accommodation vehicles Caravan holiday homes Habitation requirements relating to health and safety The European Standard EN 1647:1998, with the incorporation of amendments A1:2001 and A2:2001, has the status of a British S
2、tandard ICS 43.100 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW Licensed Copy: sheffieldun sheffieldun, na, Fri Nov 17 08:38:18 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS EN 1647:1999 This British Standard, having been prepared under the direction of the Sector Committee
3、 for Building and Civil Engineering, was published under the authority of the Standards Committee and comes into effect on 15 February 1999 BSI 08 May 2002 ISBN 0 580 30295 4 National foreword This British Standard is the English language version of EN 1647:1998, including amendments A1:2001 and A2:
4、2001. It supersedes BS 6764:1991 which is declared obsolescent. The UK participation in its preparation was entrusted to Technical Committee B/511, Buildings Mobile and temporary, which has the responsibility to: A list of organizations represented on this committee can be obtained on request to its
5、 secretary. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Standards Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Find” facility of the BSI Sta
6、ndards Electronic Catalogue. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirer
7、s to understand the text; present to the responsible European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. Summary of pages This document comprises a
8、front cover, an inside front cover, the EN title page, pages 2 to 27 and a back cover. The BSI copyright notice displayed in this document indicates when the document was last issued. Sidelining in this document indicates the most recent changes by amendment. Amendments issued since publication Amd.
9、 No. Date Comments 1324927 November 2001 Amendment to 6.5.2 1370208 May 2002 Indicated by a sideline Licensed Copy: sheffieldun sheffieldun, na, Fri Nov 17 08:38:18 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 1647 July 1998 + A1 April 2001 + A2 Dec
10、ember 2001 ICS 43.100 Descriptors: mobile homes, safety requirements, accident prevention, specifications, tests, design, equipment specification, appointments, protection, water supply, electrical installation, gas installation, ventilation, fire protection, emergency exits, technical notices Engli
11、sh version Leisure accommodation vehicles Caravan holiday homes Habitation requirements relating to health and safety (includes amendments A1:2001 and A2:2001) Vhicules habitables de loisirs Rsidences mobiles Exigences dhabitation relatives la sant et la scurit (inclut les amendements A1:2001 et A2:
12、2001) Bewohnbare Freizeitfahrzeuge Mobilheime Anforderungen an den Wohnbereich hinsichtlich Gesundheit und Sicherheit (enthlt nderungen A1:2001 und A2:2001) This European Standard was approved by CEN on 1 July 1998. Amendment A1:2001 was approved by CEN on 20 January 2001 and amendment A2:2001 was a
13、pproved by CEN on 16 November 2001. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nat
14、ional standards may be obtained on application to the Central Secretariat or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and n
15、otified to the Central Secretariat has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerlan
16、d and United Kingdom. CEN European Committee for Standardization Comit Europen de Normalisation Europisches Komitee fr Normung Central Secretariat: rue de Stassart 36, B-1050 Brussels 1998 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. N
17、o. EN 1647:1998 + A1:2001 + A2:2001 E Licensed Copy: sheffieldun sheffieldun, na, Fri Nov 17 08:38:18 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 1647:1998 BSI 08 May 2002 2 Foreword This European Standard has been prepared by Technical Committee CEN/TC 245, Leisure accommodation vehicles, the Sec
18、retariat of which is held by BSI. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by January 1999, and conflicting national standards shall be withdrawn at the latest by January 1999. According to th
19、e CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, S
20、weden, Switzerland and the United Kingdom. This Standard is one of a series covering the habitation aspects of leisure accommodation vehicles. The Standard includes nine normative annexes. Licensed Copy: sheffieldun sheffieldun, na, Fri Nov 17 08:38:18 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 1
21、647:1998 BSI 08 May 2002 3 Foreword to amendment A1 This amendment EN 1647:1998/A1:2001 to EN 1647:1998 has been prepared by Technical Committee CEN/TC 245, Leisure accommodation vehicles, the Secretariat of which is held by BSI. This amendment to the European Standard EN 1647:1998 shall be given th
22、e status of a national standard, either by publication of an identical text or by endorsement, at the latest by October 2001, and conflicting national standards shall be withdrawn at the latest by October 2001. According to the CEN/CENELEC Internal Regulations, the national standards organizations o
23、f the following countries are bound to implement this European Standard: Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and the United Kingdom Foreword to amendment A2 This am
24、endment EN 1647:1998/A2:2001 to EN 1647:1998 has been prepared by Technical Committee CEN/TC 245, Leisure accommodation vehicles, the Secretariat of which is held by BSI. This amendment to the European Standard EN 1647:1998 shall be given the status of a national standard, either by publication of a
25、n identical text or by endorsement, at the latest by June 2002, and conflicting national standards shall be withdrawn at the latest by June 2002. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European St
26、andard: Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and the United Kingdom Contents Page Foreword2 1Scope5 2References5 3Definitions5 4Testing5 5Design and construction5 6I
27、nternal equipment7 7Drinking water supply and drainage systems9 8Installations9 9Ventilation10 10Fire precautions10 11Warning notice12 12Users handbook13 Annex A (normative) Thermal insulation Method of calculation (see 5.7)14 Annex B (informative) Examples of acceptabe provisions for chassis holdin
28、g down points (see 5.11)19 Annex C (normative) Clear height over bunks (see 6.1.2)20 Annex D (normative) Strength of curtains or nets designed to prevent occupants from falling out of bunks (see 6.1.3.3)21 Annex E (normative) Mechanical strength of bunks (see 6.1.4)22 Annex F (normative) Security of
29、 folding bunks (see 6.1.5)23 Annex G (normative) Safety of access to upper bunks (see 6.1.6)24 Annex H (normative) Measurement of gaps (see 6.1.7)26 Annex K (normative) Test equipment27 Table A.1 Typical surface resistance values14 Table A.2 Typical thermal conductivity values ?15 Table A.3 Typical
30、air space thermal resistances16 Table A.4 Typical thermal transmittance values for windows, Uz16 Table A.5 Recording of thermal insulation calculations18 Figure G.1 Ladder attachment and deflection 25 Figure H.1 Cone measuring device26 Figure K.1 Typical flexible load spreading device27 Licensed Cop
31、y: sheffieldun sheffieldun, na, Fri Nov 17 08:38:18 GMT+00:00 2006, Uncontrolled Copy, (c) BSI 4 blank Licensed Copy: sheffieldun sheffieldun, na, Fri Nov 17 08:38:18 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 1647:1998 BSI 08 May 2002 5 1 Scope This European Standard specifies requirements inten
32、ded to ensure safety and health of persons using caravan holiday homes as defined in clause 3, as temporary or seasonal accommodation. It specifies grades of resistance to snow loads and the stability of the structure of caravan holiday homes as well as the minimum information to be included in a us
33、ers handbook. It also specifies the corresponding test methods. 2 References 2.1 Normative references This European Standard incorporates, by dated or by undated reference, provisions from other publications. These normative references are cited at the appropriate places in the text and the publicat
34、ions are listed hereafter. For dated references, subsequent amendments to or revisions of any of these publications apply to this European Standard only when incorporated in it by amendment or revision. For undated references, the latest edition of the publication referred to applies. EN 27418, Leis
35、ure accommodation vehicles Vocabulary. (ISO 7418:1989) prEN 624, LPG space heating equipment in vehicles and boats. EN 721, Leisure accommodation vehicles Safety ventilation requirements. EN 722-1, Leisure accommodation vehicles Liquid fuel fired heating systems Part 1: Caravans and mobile homes (ca
36、ravan holiday homes). EN 1949, Specification for the installation of LPG-systems for habitation purposes in leisure accommodation vehicles and other vehicles. HD 384.7.708 S1, Electrical installations of buildings Part 7: Requirements for special installations or locations Section 708: electrical in
37、stallations in caravan parks and caravans. 3 Definitions For the purposes of this standard the definitions given in EN 27418 apply and the following definition: 3.1 caravan holiday home transportable leisure accommodation vehicle that does not meet requirements for construction and use of road vehic
38、les, that retains means for mobility and that is for temporary or seasonal occupation 4 Testing The tests described in annexes A to J, are intended to verify that a caravan holiday home representative of a given model including its fixtures and fittings, meets the requirements of this standard. Thes
39、e tests are intended to simulate the most onerous conditions, for the relevant characteristics. 5 Design and construction 5.1 Occupancy The manufacturer shall designate the occupancy as the number of berths provided, both standard and additional berths, provided by the manufacturer and shall include
40、 it in the users handbook and his brochures. The occupancy is also necessary to determine the ventilation requirements (see EN 721). 5.2 Ceiling height The ceiling height, measured internally from finished floor level to underside of finished ceiling, shall be not less than 1 980 mm. Licensed Copy:
41、sheffieldun sheffieldun, na, Fri Nov 17 08:38:18 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 1647:1998 6 BSI 08 May 2002 5.3 Windows The living area, the area for meals, the kitchen and the sleeping accommodation shall each be provided with windows, the total glazed areas of which shall be equival
42、ent to not less than 10 % of their respective floor areas. Windows to the living area, the area for meals and the kitchen shall have an openable area equivalent to 5 % of each respective floor area (see also 10.1.6). 5.4 Doors At least one exterior door which opens outwards shall be provided. 5.5 Gl
43、azing Glass in windows, panels and doors that is less than 800 mm above finished floor level shall be safety glazing. 5.6 Kitchen location When a separate kitchen compartment is provided, that can be closed off from other parts of the caravan holiday home by fully closing doors, there shall be two d
44、oors, separated by a space, ventilated to the exterior, between the kitchen and the toilet compartment. 5.7 Classification of thermal insulation and heating The thermal insulation and heating levels for specific climatic conditions shall be classified as follows: a) Grade 1: A caravan holiday home,
45、including windows, doors and roof-lights in which the average thermal transmittance (U) of the elements of construction shall not exceed 1,7 W/(m2?K). There is no heating requirement for this grade. b) Grade 2: A caravan holiday home, including windows, doors and roof-lights in which the average the
46、rmal transmittance (U) of the elements of construction shall not exceed 1,7 W/(m2?K). An average temperature difference of at least 20 K between inside and outside temperatures shall be achieved in lounge, dining room and kitchen, when the outside temperature is 0?C. c) Grade 3: A caravan holiday ho
47、me, including windows, doors and roof-lights in which the average thermal transmittance (U) of the elements of construction shall not exceed 1,2 W/(m2?K). An average temperature difference of at least 35 K between inside and outside temperatures shall be achieved in all rooms, except the toilet comp
48、artment, when the outside temperature is?15?C. Precautions shall be taken to ensure that all services still operate when the outside temperature is?15?C. For grade 1 the average thermal transmittance (U) shall be calculated in accordance with the relevant parts of Annex A. For grades 2 and 3, the av
49、erage thermal transmittance (U value) and heating requirements shall be calculated in accordance with Annex A. 5.8 Roof space ventilation Where there is an air gap between the external roof skin and the insulation material this air gap shall be ventilated to the external air at both ends of the roof. If space allows, one high level and one low level ventilator shall be provided at both ends. 5.9 Floor Underfloor insulation, if provided, shall be protected to reduce the possibility of degradation by birds or