BS-EN-50412-2-1-2005.pdf
《BS-EN-50412-2-1-2005.pdf》由会员分享,可在线阅读,更多相关《BS-EN-50412-2-1-2005.pdf(22页珍藏版)》请在三一文库上搜索。
1、BRITISH STANDARD BS EN 50412-2-1:2005 Power line communication apparatus and systems used in low-voltage installations in the frequency range 1,6 MHz to 30 MHz Part 2-1: Residential, commercial and industrial environment Immunity requirements The European Standard EN 50412-2-1:2005 has the status of
2、 a British Standard ICS 33.120.20; 97.120 ? Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 06 08:39:37 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS EN 50412-2-1:2005 This British Standard was published under the authority of the Standards Policy and Strategy Committee on 12 December 2005 BSI 1
3、2 December 2005 ISBN 0 580 46927 1 National foreword This British Standard is the official English language version of EN 50412-2-1:2005. The UK participation in its preparation was entrusted to Technical Committee PEL/205, Mains signalling, which has the responsibility to: A list of organizations r
4、epresented on this committee can be obtained on request to its secretary. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence In
5、dex”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself co
6、nfer immunity from legal obligations. aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep UK interests informed; monitor related international and European developments and promulgate
7、 them in the UK. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 18, an inside back cover and a back cover. The BSI copyright notice displayed in this document indicates when the document was last issued. Amendments issued since publicatio
8、n Amd. No. DateComments Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 06 08:39:37 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EUROPEAN STANDARD EN 50412-2-1 NORME EUROPENNE EUROPISCHE NORM September 2005 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisat
9、ion Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2005 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 50412-2-1:2005 E ICS 33.120.20; 97.120 English v
10、ersion Power line communication apparatus and systems used in low-voltage installations in the frequency range 1,6 MHz to 30 MHz Part 2-1: Residential, commercial and industrial environment Immunity requirements Equipements et systmes de communication par courants porteurs utiliss dans les installat
11、ions basse tension dans la gamme de frquences de 1,6 MHz 20 MHz Partie 2-1: Environnement rsidentiel, commercial et de lindustrie lgre Exigences dimmunit Kommunikationsgerte und -systeme auf elektrischen Niederspannungsnetzen im Frequenzbereich 1,6 MHz bis 30 MHz Teil 2-1: Fr den Gebrauch in Wohnber
12、eichen, Geschfts- und Gewerbebereichen sowie in Kleinbetrieben und in industriellen Rumlichkeiten Strfestigkeitsanforderungen This European Standard was approved by CENELEC on 2005-04-12. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for
13、 giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three offic
14、ial versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical commi
15、ttees of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. Licensed Copy: shef
16、fieldun sheffieldun, na, Mon Nov 06 08:39:37 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 50412-2-1:2005 2 Contents Page Foreword .3 1 Scope .4 2 Normative references.4 3 Definitions and abbreviations.5 3.1 Definitions 5 3.2 Abbreviations .6 4 Objective 7 5 Description of locations7 6 Conditions du
17、ring testing7 7 Performance criteria.8 8 Narrow band responses retail outlets, e.g. shops and supermarkets; business premises, e.g. offices and banks; areas of public entertainment e.g. cinemas, public bars and dance halls; outdoors locations e.g. petrol locations, car parks, amusements and sports c
18、entres; light-industrial locations e.g. workshops, laboratories and service centres. Class 2 locations are characterised by the existence of one or more of the following conditions: a power network exists powered by a high or medium voltage power transformer dedicated for the supply of an installati
19、on feeding manufacturing or similar plant; industrial, scientific and medical (ISM) apparatus are present; heavy inductive or capacitive loads are frequently switched; currents and associated magnetic fields are high. 6 Conditions during testing A minimum test configuration consists of two pieces of
20、 powerline communications equipment interconnected with manufacturer specified physical cable. Associated equipment necessary to the function of the powerline network shall be included in the test configuration. The system shall be capable of transmitting and receiving data at the nominal transmissi
21、on rate specified by the manufacturer. The powerline equipment shall execute a programme that exercises all the functions available to the end user. As a minimum the functions described in Clause 7 of this standard “Performance criteria” shall be tested. Licensed Copy: sheffieldun sheffieldun, na, M
22、on Nov 06 08:39:37 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 50412-2-1:2005 8 7 Performance criteria Performance criterion A During and after the test, the EUT shall operate without protocol failure, loss of link, any other loss of functions relevant to the user, reduction in performance below t
23、hat declared by the manufacturer. The manufacturer shall choose the most appropriate performance measurement criteria for their apparatus or system e.g. bit error rate, block error rate, throughput, re-transmissions etc. Performance criterion B Degradation of the performance beyond that as described
24、 in criterion A is permitted during the application of the test provided that the normal operation of the EUT is self-recoverable to the condition immediately before the application of the test. Performance criterion C Degradation of the performance beyond that as described in criterion A is permitt