BS-EN-50382-2-2008.pdf
《BS-EN-50382-2-2008.pdf》由会员分享,可在线阅读,更多相关《BS-EN-50382-2-2008.pdf(28页珍藏版)》请在三一文库上搜索。
1、BRITISH STANDARD BS EN 50382-2:2008 Railway applications Railway rolling stock high temperature power cables having special fire performance Part 2: Single core silicone rubber insulated cables for 120 C or 150 C ICS 13.220.40; 29.060.20; 45.060.01 ? BS EN 50382-2:2008 This British Standard was publ
2、ished under the authority of the Standards Policy and Strategy Committee on 30 May 2008 BSI 2008 ISBN 978 0 580 63043 9 National foreword This British Standard is the UK implementation of EN 50382-2:2008. The UK participation in its preparation was entrusted by Technical Committee GEL/20, Electric c
3、ables, to Subcommittee GEL/20/12, Railway cables. A list of organizations represented on this committee can be obtained on request to its secretary. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance
4、with a British Standard cannot confer immunity from legal obligations. Amendments/corrigenda issued since publication DateComments EUROPEAN STANDARD EN 50382-2 NORME EUROPENNE EUROPISCHE NORM March 2008 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation El
5、ectrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2008 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 50382-2:2008 E ICS 13.220.40; 29.060.20; 45.060.01 Eng
6、lish version Railway applications - Railway rolling stock high temperature power cables having special fire performance - Part 2: Single core silicone rubber insulated cables for 120 C or 150 C Applications ferroviaires - Cbles pour matriel roulant ferroviaire ayant des performances particulires de
7、comportement au feu - Partie 2: Cbles monoconducteurs isols au silicone pour 120 C ou 150 C Bahnanwendungen - Hochtemperaturkabel und -leitungen fr Schienenfahrzeuge mit verbessertem Verhalten im Brandfall - Teil 2: Einadrige silikonisolierte Leitungen fr 120 C oder 150 C This European Standard was
8、approved by CENELEC on 2008-02-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such
9、national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own lan
10、guage and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, La
11、tvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. EN 50382-2:2008 2 Foreword This European Standard was prepared for the Technical Committee CENELEC TC 20, Electric cables, by Working Group 1
12、2, Railway Cables, as part of the overall programme of work in the Technical Committee CENELEC TC 9X, Electrical and electronic applications for railways. The text of the draft was submitted to the formal vote and was approved by CENELEC as EN 50382-2 on 2008-02-01. The following dates were fixed: l
13、atest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2009-02-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2011-02-01 BS EN 50382-2:2008 3 EN 50382-2:2008 Conten
14、ts Introduction 4 1 Scope 5 2 Normative references . 5 3 Definitions 6 4 Rated voltage . 6 5 Marking and identification . 6 5.1 Marking of cable . 6 5.2 Colour identification 7 6 Construction of cables 7 6.1 General . 7 6.2 Conductor . 7 6.3 Conductor screening . 7 6.4 Separator 7 6.5 Insulation sys
15、tem 8 6.6 Sheath 8 6.7 Textile braid 8 6.8 Constructional components . 9 7 Tests . 15 7.1 Definitions relating to tests 15 7.2 Conductor resistance 15 7.3 Voltage test 15 7.4 Insulation resistance . 15 7.5 Dielectric strength . 16 7.6 Spark test . 16 7.7 D.C. stability . 16 7.8 Surface resistance 16
16、 7.9 Ageing test . 17 7.10 Long term ageing test . 17 7.11 Hot set test . 17 7.12 Compatibility . 17 7.13 Water absorption test 17 7.14 Ozone resistance 18 7.15 Mineral oil resistance 18 7.16 Acid Part 2: Single core silicone rubber insulated cables for 120 C or 150 C. Special test methods referred
17、to in EN 50382 are given in EN 50305. A Guide to Use is given in EN 50355. Information regarding selection and installation of cables, including current ratings can be found in EN 50355 and EN 50343. The procedure for selection of conductor cross-sectional area, including reduction factors for ambie
18、nt temperature and installation type, is described in EN 50343. NOTE Current ratings for inclusion in EN 50355 are under development for the next amendment. Part 1, General requirements, contains a more extensive introduction to EN 50382, and should be read in conjunction with this Part 2. BS EN 503
19、82-2:2008 5 EN 50382-2:2008 1 Scope Part 2 of EN 50382 specifies requirements for, and constructions and dimensions of, single core cables of the following types and voltage ratings: 1,8/3 kV unscreened, unsheathed with or without textile braid (1,5 mm to 400 mm); 1,8/3 kV unscreened, sheathed (1,5
20、mm to 400 mm); 3,6/6 kV unscreened, unsheathed with or without textile braid (2,5 mm to 400 mm); 3,6/6 kV unscreened, sheathed (2,5 mm to 400 mm). All cables have class 5 or class 6 tinned or plain copper conductors to EN 60228, halogen-free insulation and where applicable halogen-free sheath. They
21、are for use in railway rolling stock as fixed wiring, or wiring where limited flexing in operation is encountered. The requirements provide for a continuous conductor temperature not exceeding 120 C or 150 C and a maximum temperature for short circuit conditions of either 250 C or 350 C based on a d
22、uration of 5 s. When the insulating compounds and sheath specified in this standard which are thermally capable of operating at 150 C are used with tinned conductors, the maximum operating temperature is limited to 120 C and, for the same technical reason, the maximum short circuit temperature is li
23、mited to 250 C. The choice of sheath may also limit the maximum operating temperature to 120 C. A textile braid may be included in the insulation or applied at its surface to unsheathed cables. Under fire conditions the cables exhibit special performance characteristics in respect of maximum permiss
24、ible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases. This Part 2 of EN 50382 should be used in conjunction with Part 1 “General requirements”. 2 Normative references The following referenced documents are indispensable for the application of this document.
- 配套讲稿: