BS-EN-60060-3-2006.pdf
《BS-EN-60060-3-2006.pdf》由会员分享,可在线阅读,更多相关《BS-EN-60060-3-2006.pdf(36页珍藏版)》请在三一文库上搜索。
1、BRITISH STANDARD BS EN 60060-3:2006 Incorporating corrigendum no. 1 High voltage test techniques Part 3: Definitions and requirements for on-site tests The European Standard EN 60060-3:2006 has the status of a British Standard ICS 17.220.20; 19.080 ? Licensed Copy: London South Bank University, Lond
2、on South Bank University, Thu Jan 18 00:54:08 GMT+00:00 2007, Uncontrolled Copy, (c) BSI BS EN 60060-3:2006 This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 March 2006 BSI 2006 ISBN 0 580 48084 4 National foreword This British Standard was
3、published by BSI. It is the UK implementation of EN 60060-3:2006, incorporating Corrigendum October 2006. It is identical with IEC 60060-3:2006. The UK participation in its preparation was entrusted to Technical Committee PEL/42, Testing techniques for high voltages and currents. A list of organizat
4、ions represented on PEL/42 can be obtained on request to its secretary. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard cannot confer immunity from legal obligations. Amendm
5、ents issued since publication Amd. No. DateComments 16784 Corrigendum No. 1 29 December 2006Change to EN foreword and addition of Annex ZA Licensed Copy: London South Bank University, London South Bank University, Thu Jan 18 00:54:08 GMT+00:00 2007, Uncontrolled Copy, (c) BSI EUROPEAN STANDARD EN 60
6、060-3 NORME EUROPENNE EUROPISCHE NORM March 2006 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2006 CENELEC - All rights of ex
7、ploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 60060-3:2006 E ICS 17.220.20; 19.080 English version High voltage test techniques Part 3: Definitions and requirements for on-site tests (IEC 60060-3:2006) Techniques des essais haute tension Partie 3: Dfinit
8、ions et prescriptions pour des essais sur site (CEI 60060-3:2006) Hochspannungs-Prftechnik Teil 3: Begriffe und Anforderungen fr Vor-Ort-Prfungen (IEC 60060-3:2006) This European Standard was approved by CENELEC on 2006-02-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulat
9、ions which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This
10、European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members
11、are the national electrotechnical committees of Austria, Belgium, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Swe
12、den, Switzerland and the United Kingdom. Incorporating Corrigendum October 2006 Licensed Copy: London South Bank University, London South Bank University, Thu Jan 18 00:54:08 GMT+00:00 2007, Uncontrolled Copy, (c) BSI Foreword The text of document 42/203/FDIS, future edition 1 of IEC 60060-3, prepar
13、ed by IEC TC 42, High-voltage testing techniques, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 60060-3 on 2006-02-01. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standa
14、rd or by endorsement (dop) 2006-11-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2009-02-01 _ Endorsement notice The text of the International Standard IEC 60060-3:2006 was approved by CENELEC as a European Standard without any modification. _ 2 EN
15、 60060-3:2006 Annex ZA has been added by CENELEC. Licensed Copy: London South Bank University, London South Bank University, Thu Jan 18 00:54:08 GMT+00:00 2007, Uncontrolled Copy, (c) BSI 3 CONTENTS INTRODUCTION.5 1 Scope 6 2 Normative references .6 3 Terms and definitions .6 4 Common tests and chec
16、ks on a measuring system11 4.1 Acceptance test.11 4.2 Performance test .11 4.3 Performance check11 4.4 Record of performance 12 5 Tests with direct voltage .12 5.1 General.12 5.2 Definitions for direct voltage tests 12 5.3 Test voltage 13 5.4 Measurement of the test voltage 13 5.5 Tests and checks o
17、n measuring systems14 5.6 Withstand voltage test procedure .14 6 Tests with alternating voltage .14 6.1 General.14 6.2 Definitions for alternating voltage tests.14 6.3 Test voltage 15 6.4 Measurement of the test voltage 16 6.5 Tests and checks on measuring systems17 6.6 Withstand voltage test proced
18、ure .17 7 Tests with lightning impulse voltage17 7.1 General.17 7.2 Definitions for lightning impulse voltage tests .17 7.3 Test voltage 20 7.4 Measurement of the test voltage and determination of the impulse voltage shape21 7.5 Tests and checks on measuring systems21 7.6 Withstand voltage test proc
19、edures .22 8 Tests with switching impulse voltage.22 8.1 General.22 8.2 Definitions for switching impulse voltage tests22 8.3 Test voltage 25 8.4 Measurement of the test voltage and determination of the impulse shape .25 8.5 Tests and checks on measuring systems26 8.6 Withstand voltage test procedur
20、es .26 9 Tests with very low frequency voltages .27 9.1 General.27 9.2 Definitions for very low frequency voltage tests 27 9.3 Test voltage 28 9.4 Measurement of the test voltage 28 9.5 Tests and checks on measuring systems29 9.6 Test procedure 29 10 Tests with damped alternating voltages.29 EN 6006
21、0-3:2006 Licensed Copy: London South Bank University, London South Bank University, Thu Jan 18 00:54:08 GMT+00:00 2007, Uncontrolled Copy, (c) BSI 4 10.1 General.29 10.2 Definitions for damped alternating voltage tests .29 10.3 Test voltage 30 10.4 Measurement of the test voltage 31 10.5 Tests and c
22、hecks on measuring systems31 10.6 Test procedure 32 Figure 1 Aperiodic lightning impulse.18 Figure 2 Oscillating lightning impulse .19 Figure 3 Aperiodic switching impulse23 Figure 4 Oscillating switching impulse 24 Figure 5 Damped alternating voltage (fr = 1 kHz, Df = 0,2) .30 EN 60060-3:2006 Annex
23、 ZA (normative) Normative references to international publications with their corresponding European publications 33 Licensed Copy: London South Bank University, London South Bank University, Thu Jan 18 00:54:08 GMT+00:00 2007, Uncontrolled Copy, (c) BSI 5 INTRODUCTION The requirements specified in
24、IEC 60060-1 and IEC 60060-2 cannot always be achieved during on-site tests, due to a variety of external factors not present in factory and laboratory tests such as external electric and magnetic fields, weather conditions, etc. On-site high-voltage tests are required: as withstand tests as part of