BS-EN-60310-2004.pdf
《BS-EN-60310-2004.pdf》由会员分享,可在线阅读,更多相关《BS-EN-60310-2004.pdf(32页珍藏版)》请在三一文库上搜索。
1、BRITISH STANDARD BS EN 60310:2004 Railway applications Traction transformers and inductors on board rolling stock The European Standard EN 60310:2004 has the status of a British Standard ICS 45.060 ? BS EN 60310:2004 This British Standard was published under the authority of the Standards Policy and
2、 Strategy Committee on 30 April 2004 BSI 30 April 2004 ISBN 0 580 43722 1 National foreword This British Standard is the official English language version of EN 60310:2004. It is identical with IEC 60310:2004. It supersedes BS EN 60310:1997 which is withdrawn. The UK participation in its preparation
3、 was entrusted by Technical Committee GEL/9, Railway electrotechnical applications, to Subcommittee GEL/9/2, Rolling stock, which has the responsibility to: A list of organizations represented on this subcommittee can be obtained on request to its secretary. Cross-references The British Standards wh
4、ich implement international or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online. This public
5、ation does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the text; present to the responsible internationa
6、l/European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. Summary of pages This document comprises a front cover, an inside front cover, the EN title pa
7、ge, pages 2 to 28, an inside back cover and a back cover. The BSI copyright notice displayed in this document indicates when the document was last issued. Amendments issued since publication Amd. No. DateComments EUROPEAN STANDARD EN 60310 NORME EUROPENNE EUROPISCHE NORM April 2004 CENELEC European
8、Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2004 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CEN
9、ELEC members. Ref. No. EN 60310:2004 E ICS 45.060 Supersedes EN 60310:1996 English version Railway applications Traction transformers and inductors on board rolling stock (IEC 60310:2004) Applications ferroviaires - Transformateurs de traction et bobines dinductance bord du matriel roulant (CEI 6031
10、0:2004) Bahnanwendungen Transformatoren und Drosselspulen auf Bahnfahrzeugen (IEC 60310:2004) This European Standard was approved by CENELEC on 2004-03-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard t
11、he status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, G
12、erman). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Cypru
13、s, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. Foreword The text of document 9/780/FDIS, future ed
14、ition 3 of IEC 60310, prepared by IEC TC 9, Electrical equipment and systems for railways, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 60310 on 2004-03-01. This European Standard supersedes EN 60310:1996. This European Standard includes the following significant
15、technical changes from EN 60310:1996: it takes into account the new generic railway standards, more specifically general service conditions and shock and vibration considerations, referring to EN 60077-1 and EN 61373. The following dates were fixed: latest date by which the EN has to be implemented
16、at national level by publication of an identical national standard or by endorsement (dop) 2004-12-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2007-03-01 Annex ZA has been added by CENELEC. _ Endorsement notice The text of the International Stand
17、ard IEC 60310:2004 was approved by CENELEC as a European Standard without any modification. _ Page 2 EN 60310:2004 CONTENTS 1 Scope.4 2 Normative references .4 3 Terms and definitions .5 3.1 Definitions for transformers .5 3.2 Definitions for inductors.5 3.3 Definitions for inductance 6 4 Tappings 7
18、 4.1 Principal tapping .7 5 Rated voltages of transformer windings7 5.1 Rated line-side voltage7 5.2 Rated secondary voltage.8 6 Rated power.8 7 Cooling.8 7.1 Identification of transformers and inductors according to cooling method.8 8 Limits of temperature rise.9 8.1 Classification of insulating ma
19、terials9 8.2 Limits of temperature-rise10 9 Rating plates 11 9.1 Transformer rating plate 11 9.2 Inductor rating plate 11 10 Tests12 10.1 Categories of tests 12 10.2 Tests on transformers .12 10.3 Tests on inductors.21 Annex A (informative) List of items for which an agreement between user and manuf
20、acturer is needed or for which further information or specifications shall be given by the user or by the manufacturer .26 Annex ZA (normative) Normative references to international publications with their corresponding European publications 28 Table 1 Letter symbols.8 Table 2 Order of symbols.9 Tab
21、le 3 Limits of temperature-rise (K)10 Table 4 List of checks and tests to be made on traction transformers.13 Table 5 Tolerances 13 Table 6 Reference temperatures17 Table 7 Dielectric test voltages for windings directly connected to the contact line.18 Table 8 Dielectric test voltage U in volts (ind
22、uced voltage or separate source voltage withstand test) for other windings (r.m.s.) .19 Table 9 List of checks and tests to be made on inductors.21 Table 10 Tolerances 21 Page 3 EN 60310:2004 INTERNATIONAL ELECTROTECHNICAL COMMISSION _ RAILWAY APPLICATIONS TRACTION TRANSFORMERS AND INDUCTORS ON BOAR
23、D ROLLING STOCK 1 Scope This International Standard applies to traction transformers installed on board rolling stock and to the various types of inductors inserted in the power and auxiliary circuits of electric vehicles. NOTE 1 The term “inductor” is used in this standard with the same meaning as
24、the term “reactor” mentioned in IEC 60050(421), IEC 60050(811) and IEC 60289. The inductors mentioned in the first paragraph may be: filter inductors; smoothing inductors; commutation inductors; protection inductors in static power convertors; inductive shunts for traction motors; inductors used for