《BS-EN-60335-2-63-1993.pdf》由会员分享,可在线阅读,更多相关《BS-EN-60335-2-63-1993.pdf(20页珍藏版)》请在三一文库上搜索。
1、BRITISH STANDARD BS EN 60335-2-63: 1993 Incorporating Amendment No. 1 Specification for Safety of household and similar electrical appliances Part 2: Particular requirements Section 2.63 Commercial electric water boilers and liquid heaters The European Standard EN 60335-2-63:1993 has the status of a
2、 British Standard UDC 64.06-83:641.542.1:620.1:614.8 Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 13 17:11:01 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS EN 60335-2-63:1993 This British Standard, having been prepared under the direction of the Light Electrical Engineering Standards Policy C
3、ommittee, was published under the authority of the Standards Board and comes into effect on 15 July 1993 BSI 02-2000 The following BSI references relate to the work on this standard: Committee reference LEL/61/7 Special announcement in BSI News July 1993 ISBN 0 580 22436 8 Cooperating organizations
4、The European Committee for Electrotechnical Standardization (CENELEC), under whose supervision this European Standard was prepared, comprises the national committees of the following countries: AustriaItaly BelgiumLuxembourg DenmarkNetherlands FinlandNorway FrancePortugal GermanySpain GreeceSweden I
5、celandSwitzerland IrelandUnited Kingdom Amendments issued since publication Amd. No.DateComments 8780September 1995 Indicated by a sideline in the margin Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 13 17:11:01 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS EN 60335-2-63:1993 BSI 02-2000i Cont
6、ents Page Cooperating organizationsInside front cover National forewordii Foreword2 Text of EN 60335-2-633 National annex NA (informative) Original IEC text amended by CENELEC common modifications12 National annex NB (informative) Committees responsible13 National annex NC (informative) Cross-refere
7、nces14 Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 13 17:11:01 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS EN 60335-2-63:1993 ii BSI 02-2000 National foreword This British Standard has been prepared under the direction of the Light Electrical Engineering Standards Policy Committee and is t
8、he English language version of EN 60335-2-63:1993, Safety of household and similar electrical appliances Part 2: Particular requirements for commercial electric water boilers and liquid heaters including corrigendum January 1995, published by the European Committee for Electrotechnical Standardizati
9、on (CENELEC). It was derived by CENELEC from IEC 335-2-63:1990 published by the International Electrotechnical Commission (IEC). The CENELEC common modifications have been implemented at the appropriate places in the text and are indicated by a side line in the margin. Parts of the original IEC text
10、 that have been modified by CENELEC have been quoted in National annex NA. This British Standard is to be read in conjunction with BS 3456-201:1990 General requirements, including the Amendments shown in the following table which supplement and modify BS 3456-201. The interrelationships of the Amend
11、ments to IEC 335-1:1976, EN 60335-1:1988 and BS 3456-201:1990 are also shown in the table. The many references to Part 1 should be read as references to BS 3456-201, which is the English language version of EN 60335-1, which was derived from the 1983 reprint of IEC 335-1:1976 including Amendments 1,
12、 2 and 3 to IEC 335-1:1976. British Standards BS 4167-6:1969 and BS 4167-7:1969 will be withdrawn on 1 December 1995. For products conforming to BS 4167-6:1969 and BS 4167-7:1969 before 1 December 1995, these standards may continue to apply for production until 1 December 2000. A British Standard do
13、es not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Amendment to BS 3456-201:1990 Amendment to EN 60335-1:1988 Ame
14、ndment to IEC 335-1:1976 Amendment No. 1:1990Amendment 2:1988aAmendment No. 4:1984 Amendment No. 2:1990Amendment 5:1989aAmendment No. 5:1986 Amendment No. 3:1990Amendment 6:1989aAmendment No. 6:1988 Amendment No. 4:1992Amendment A51:1991 Amendment No. 5:1992Amendment A52:1992 Amendment No. 6:1992Ame
15、ndment A53:1992 Amendment No. 7:1993Amendment A54:1992 a These Amendments to EN 60335-1 implement, with additions and modifications, the corresponding Amendments to IEC 335-1. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, the EN title page, pages 2 to
16、 14 and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover. Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 13 17:11:01 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EURO
17、PEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 60335-2-63 April 1993 UDC 64.06-83:641.542.1:620.1:614.8 Descriptors: Household electrical appliances, liquid heaters, water boilers, appliance for commercial use, safety requirements, protection against electric shock, fire protection, protection aga
18、inst mechanical hazard English version Safety of household and similar electrical appliances Part 2: Particular requirements for commercial electric water boilers and liquid heaters (IEC 335-2-63:1990, modified) Scurit des appareils lectrodomestiques et analogues Deuxime partie: Rgles particulires p
19、our les appareil lectriques eau bouillante et les appareils lectriques de chauffage des liquides usage collectif (CEI 335-2-63:1990, modifie) Sicherheit elektrischer Gerte fr den Hausgebrauch und hnliche Zwecke Teil 2: Besondere Anforderungen fr gewerbliche elektrische Wassererwrmer und Flssigkeitse
20、rwrmer (IEC 335-2-63:1990, modifiziert) This European Standard was approved by CENELEC on 9 March 1993. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alterat
21、ion. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by tran
22、slation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Denmark, Finland, France, Germany, Greece, Iceland, Irela
23、nd, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom. CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 3
24、5, B-1050 Brussels 1993 Copyright reserved to CENELEC members Ref. No. EN 60335-2-63:1993 E Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 13 17:11:01 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 60335-2-63:1993 BSI 02-2000 2 Foreword The proposal to endorse the first edition of IEC 335-2-63,
25、document CLC/TC 61 (SEC) 755, was circulated under the enquiry procedure in November 1990. This proposal was discussed during the Baden meeting in May 1991 and during the Brussels meeting in November 1991, when it was decided to submit a draft for EN 60335-2-63 to the voting procedure. This draft wa
26、s circulated in September 1992 and was ratified by CENELEC on 9 March 1993. This European Standard has been prepared by the secretariat of CENELEC Technical Committee TC 61. The following dates are applicable: For products which have complied with the relevant national standard before 1995-12-01, as
27、 shown by the manufacturer or by a certification body, this previous standard may continue to apply for production until 2000-12-01. This standard has to be used in conjunction with EN 60335-1:1988, Safety of household and similar electrical appliances, Part 1: General requirements, including its am
28、endments A2:1988, A5:1989, A6:1989, A51:1991, A52:1992, A53:1992, A54:1992 and A55:1993. Where a particular subclause of Part 1 is not mentioned in this Part 2, that subclause applies as far as is reasonable. Where this standard states “addition”, “modification” or “replacement”, the relevant text o
29、f Part 1 is to be adapted accordingly. Subclauses which are in addition to those in Part 1 are numbered starting with 101. There are no special national conditions (snc) causing a deviation from this European Standard, other than those listed in Annex ZX of EN 60335-1. National deviations from this
30、European Standard are listed in Annex ZY and are in addition to those in EN 60335-1. Other publications quoted in this standard: EN 60529:1991. Degrees of protection provided by enclosures (IP code). The following print types are used: requirements: in roman type; test specifications: in italic type
31、; explanations: in small roman type. Contents Page Foreword2 1Scope3 2Definitions3 3General requirement4 4General notes on tests4 5Rating4 6Classification4 7Marking5 8Protection against electric shock5 9Starting of motor-operated appliances5 10Input and current5 11Heating5 12Operation under overload
32、 conditions of appliances with heating elements6 13Electrical insulation and leakage current at operating temperature6 14Radio and television interference suppression6 15Moisture resistance6 16Insulation resistance and electric strength7 17Overload protection7 18Endurance7 19Abnormal operation7 20St
33、ability and mechanical hazards8 21Mechanical strength8 22Construction8 23Internal wiring9 24Components9 25Supply connections and external flexible cables and cords9 26Terminals for external conductors9 27Provision for earthing10 28Screws and connections10 29Creepage distances, clearances and distanc
34、es through insulation10 30Resistance to heat, fire and tracking10 31Resistance to rusting10 32Radiation, toxicity and similar hazards10 Appendices11 Annex ZA (normative) Switches11 Annex ZY (informative) National deviations11 latest date of publication of an identical national standard(dop) 1993-12-
35、01 date of withdrawal of conflicting national standards(dow) 1995-12-01 Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 13 17:11:01 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 60335-2-63:1993 BSI 02-20003 1 Scope This clause of Part 1 is applicable except as follows: 1.1 Replacement: This stan
36、dard applies to electrically operated commercial water boilers and liquid heaters for the boiling or heating of liquids to be used in the preparation of beverages and not intended for household use. The electrical part of appliances making use of other forms of energy is also within the scope of thi
37、s standard. This standard does not apply to: appliances designed exclusively for industrial purposes; appliances with electrode heaters; appliances intended to be used in locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere (dust, vapour or gas). Fo
38、r appliances intended to be used in vehicles or on board ships or aircraft, additional requirements may be necessary. For appliances intended to be used in tropical countries, special requirements may be necessary. Attention is drawn to the fact that in many countries additional requirements are spe
39、cified by the national authorities responsible for health, for water supplies and for the protection of labour. In many countries additional requirements for pressure vessels are specified. 2 Definitions This clause of Part 1 is applicable except as follows: 2.2.4 Addition: The rated input is the su
40、m of the rated inputs of all the individual elements in the appliance which can be on at one time. Where there are several such combinations possible, that giving the highest input is used in determining the rated input. 2.2.19 Addition: Wherever Class II is used in this standard it is understood to
41、 mean a part of Class II construction. 2.2.20 Addition: Wherever Class III is used in this standard it is understood to mean a part of Class III construction. 2.2.29 Replacement: Conditions of adequate heat discharge denote that the appliance is operated under the following conditions: Appliances ar
42、e operated in accordance with the manufacturers instructions with all the controls intended to be operated by the user adjusted to their maximum setting. Covers or lid, if any, are placed in their intended position. Appliances intended to be filled by hand or by a manually operated tap are filled to
43、 the indicated level. Where several levels are marked, that giving the most unfavourable conditions is used. Appliances intended to be filled automatically are connected to a water supply having the pressure designated by the manufacturer. Where the manufacturer specifies a range of pressures, this
44、is adjusted to that which gives the most unfavourable conditions. The temperature of the water supplied is 15 C 5 C. If adjustment of the water level during the test is necessary, this is carried out in accordance with the manufacturers instructions. Continuous flow appliances are operated with the
45、draw-off tap open. Storage type appliances and liquid heaters are operated with the draw-off tap closed. 2.2.30 Replacement: Normal load denotes the load obtained when the motors incorporated in the appliance are operated in the intended manner under the most severe conditions which can be expected
46、in normal use taking into account the manufacturers instructions, while the appliance is operated under conditions of adequate heat discharge. Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 13 17:11:01 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 60335-2-63:1993 4 BSI 02-2000 Additional defini
47、tions: 2.2.101 a water boiler denotes an appliance designed to give continuous service with delivery of boiling water at the turn of the draw-off tap 2.2.102 a liquid heater denotes an appliance which is intended to heat liquids to below boiling-point or maintain them at a temperature below boiling-
48、point and which delivers the liquid at the turn of the draw-off tap 2.2.103 a continuous flow water boiler or continuous flow liquid heater denotes an appliance which provides boiling water or heated liquid at a continuous rate proportional to the electric input 2.2.104 a storage type water boiler o
49、r storage type liquid heater denotes an appliance which permits the storage of boiling water or heated liquid when the draw-off tap is closed 2.2.105 indicated level denotes a mark on the appliance to indicate the maximum liquid level for correct operation 2.2.106 rated pressure denotes the maximum working pressure assigned by the manufacturer to the pressurized parts of the appliance 3 General requirement This clause of Part 1 is applicable. 4 General notes on tests This clause of Part 1 is applicable except as follows: