1、BRITISH STANDARD BS EN 60870-5-1:1994 IEC 870-5-1: 1990 Incorporating Amendment No. 1 Telecontrol equipment and systems Part 5: Transmission protocols Section 5.1 Transmission frame formats The European Standard EN 60870-5-1:1993 has the status of a British Standard UDC 621.398:621.316.1:681.3.04 Li
2、censed Copy: sheffieldun sheffieldun, na, Thu Nov 09 08:37:32 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS EN 60870-5-1:1994 This British Standard, having been prepared under the direction of the Power Electrical Engineering Standards Policy Committee, was published under the authority of the Stand
3、ards Board and comes into effect on 31 October 1991 BSI 06-1999 The following BSI references relate to the work on this standard: Committee reference PEL/89 Draft for comment 89/33064 DC ISBN 0 580 20111 2 Committees responsible for this British Standard The preparation of this British Standard was
4、entrusted by the Power Electrical Engineering Standards Policy Committee (PEL/-) to Technical Committee PEL/89, upon which the following bodies were represented: Association of Consulting Engineers BAMEMA (BEAMA) BEAMA Ltd. EEA (the Association of Electronics, Telecommunications and Business Equipme
5、nt Industries) Electricity Supply Industry in United Kingdom GAMBICA (BEAMA Ltd.) North of Scotland Hydro-Electric Board Telecommunication Engineering and Manufacturing Association Transmission and Distribution Association (BEAMA Ltd.) Amendments issued since publication Amd. No.DateComments 8113Mar
6、ch 1994Indicated by a sideline in the margin Licensed Copy: sheffieldun sheffieldun, na, Thu Nov 09 08:37:32 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS EN 60870-5-1:1994 BSI 06-1999i Contents Page Committees responsibleInside front cover National forewordii Foreword2 Introduction3 1Scope5 2Object
7、5 3Requirements for data transmission in telecontrol systems5 3.1High data integrity and data consistency5 3.2Short telecontrol transfer time5 3.3Support of bit oriented (code transparent) data transmission5 4Quantified rating of data integrity5 4.1Quantitative requirements for data integrity in tel
8、econtrol systems6 5Quantified rating of transmission efficiency8 6Transmission protocol specifications8 6.1Physical layer8 6.2Link layer9 6.2.1 Link service classes provided9 6.2.2 Dialogue procedures10 6.2.3 Standard frame synchronization10 6.2.4 Standard frame formats10 6.2.5 Synchronization in tr
9、ansmission channels using switched carrier frequency18 6.2.6 Main application fields of the defined format classes18 6.2.7 Use of HDLC (High level data link control)-protocols19 Appendix A Effect of signal quality supervision on transmission efficiency and data integrity20 Appendix B Quantitative ra
10、tings of data integrity and transmission efficiency24 Annex ZA (normative) Other international publications quoted in this standard with the references of the relevant European publications30 Figure 1 Data integrity classes7 Figure A.1 Bit signal detection:22 a) without and b) with signal quality su
11、pervision Figure A.2 Influence of signal quality supervision on frame transmission efficiency and on data integrity23 Figure B.1 Residual errors of format classes FT1.1, FT1.2, FT2 and FT328 Figure B.2 Frame transmission efficiency of format classes FT1.1, FT1.2, FT2 and FT329 Table 1 Standard frame
12、 formats and code specifications12 Publication(s) referred toInside back cover Licensed Copy: sheffieldun sheffieldun, na, Thu Nov 09 08:37:32 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS EN 60870-5-1:1994 ii BSI 06-1999 National foreword This Section of BS 7404 has been prepared under the directio
13、n of the Power Electrical Engineering Standards Policy Committee and is identical with IEC Publication 870-5-1:1989 “Telecontrol equipment and systems Part 5: Transmission protocols Section 1 Transmission frame formats”, published by the international Electrotechnical Commission (IEC). In 1993 the E
14、uropean Committee for Electrotechnical Standardization (CENELEC) accepted IEC 870-5-1:1990 as European Standard EN 60870-5-1:1993. As a consequence of implementing the European Standard this British Standard is renumbered as BS EN 60870-5-1 and any reference to BS 7404-5.1 should be read as a refere
15、nce to BS EN 60870-5-1. The international standard does not give the up-to-date relation between this Part of the IEC standard and the other published and envisaged Parts and Sections. Other Parts and Sections of this British Standard are as follows. Part 1: General considerations; Section 1.1: Gene
16、ral principles; Section 1.2: Guide for specifications; Section 1.3: Glossary; Section 1.4: Basic aspects of telecontrol data transmission1); Part 2: Operating conditions; Section 2.1: Specification for classes of environmental conditions and power supplies; Section 2.2: Specification for electromagn
17、etic compatibility and erosive and corrosive influences2); Part 3: Specification for interfaces (electrical characteristics); Part 4: Specification for performance; Part 5: Transmission protocols; Section 5.1: Specification for transmission frame formats; Section 5.2: Specification for transmission
18、procedures; Section 5.3: Specification for structure of application data; Section 5.4: Specification for coding specifications of application data; Part 6: Specification for telecontrol protocols compatible with ISO and CCITT standards2). Cross-references 1) Will be published after IEC 870-1-4 has b
19、een published. 2) Not yet published, envisaged as future work by IEC. International standardCorresponding British Standard BS 7404 Telecontrol equipment and systems IEC 870-1-1:1988Section 1.1:1991 General principles (Identical) IEC 870-5-2Section 5.2 Specification for transmission procedures (Ident
20、ical) Licensed Copy: sheffieldun sheffieldun, na, Thu Nov 09 08:37:32 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS EN 60870-5-1:1994 BSI 06-1999iii A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct
21、 application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i to iv, the EN title page, pages 2 to 30, an inside back cover and a back cover. This standard has been up
22、dated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover. Licensed Copy: sheffieldun sheffieldun, na, Thu Nov 09 08:37:32 GMT+00:00 2006, Uncontrolled Copy, (c) BSI iv blank Licensed Copy: sheffieldun sheffieldun, na
23、, Thu Nov 09 08:37:32 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 60870-5-1 September 1993 UDC 621.398:621.316.1:681.3.04 Descriptors: Telecontrol, data transmission, open system interconnection, protocol, data structure, frame, format English vers
24、ion Telecontrol equipment and systems Part 5: Transmission protocols Section 1: Transmission frame formats (IEC 870-5-1:1990) Matriels et systmes de tlconduite Partie 5: Protocoles de transmission Section un: Formats de trames de transmission (CEI 870-5-1:1990) Fernwirkeinrichtungen und Fernwirksyst