BS-EN-61076-3-103-2004.pdf
《BS-EN-61076-3-103-2004.pdf》由会员分享,可在线阅读,更多相关《BS-EN-61076-3-103-2004.pdf(62页珍藏版)》请在三一文库上搜索。
1、BRITISH STANDARD BS EN 61076-3-103:2004 Connectors for electronic equipment Part 3-103: Rectangular connectors Detail specification for single row connectors with non-removable ribbon cable contacts on 1,25 mm pitch used for high speed serial data (HSSDC) The European Standard EN 61076-3-103:2004 ha
2、s the status of a British Standard ICS 31.220.10 ? BS EN 61076-3-103:2004 This British Standard was published under the authority of the Standards Policy and Strategy Committee on 26 February 2004 BSI 26 February 2004 ISBN 0 580 43487 7 National foreword This British Standard is the official English
3、 language version of EN 61076-3-103:2004. It is identical with IEC 61076-3-103:2003. The UK participation in its preparation was entrusted by Technical Committee EPL/48, Electromechanical components and mechanical structures for electronic equipment, to Subcommittee EPL/48/2, Connectors for electron
4、ic equipment, which has the responsibility to: A list of organizations represented on this subcommittee can be obtained on request to its secretary. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Cata
5、logue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its co
6、rrect application. Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests i
7、nformed; monitor related international and European developments and promulgate them in the UK. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 59 and a back cover. The BSI copyright notice displayed in this document indicates when the doc
8、ument was last issued. Amendments issued since publication Amd. No. DateComments EUROPEAN STANDARD EN 61076-3-103 NORME EUROPENNE EUROPISCHE NORM February 2004 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elekt
9、rotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2004 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 61076-3-103:2004 E ICS 31.220.10 English version Connectors for electronic equipment Part 3-103:
10、Rectangular connectors Detail specification for single row connectors with non-removable ribbon cable contacts on 1,25 mm pitch used for high speed serial data (HSSDC) (IEC 61076-3-103:2003) Connecteurs pour quipements lectroniques Partie 3-103: Connecteurs rectangulaires - Spcification particulire
11、pour les connecteurs rectangulaires avec des contacts de cbles rubans non amovibles sur une range simple de pas 1,25 mm utiliss avec des connecteurs de donnes srie grande vitesse (HSSDC) (CEI 61076-3-103:2003) Steckverbinder fr elektronische Einrichtungen Teil 3-103: Rechteckige Steckverbinder - Bau
12、artspezifikation fr einreihige Steckverbinder mit nicht auswechselbaren Kontakten mit 1,25 mm Teilung fr den Anschluss von Flachleitungen und Anwendungen in schnellen Datenbermittlungen (HSSDC) (IEC 61076-3-103:2003) This European Standard was approved by CENELEC on 2004-02-01. CENELEC members are b
13、ound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the
14、 Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the sa
15、me status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portu
16、gal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EN 67016-3-01:30024 - - 2 Foreword The text of document 48B/1373/FDIS, future edition 1 of IEC 61076-3-103, prepared by SC 48B, Connectors, of IEC TC 48, Electromechanical components and mechanical structures for electronic equi
17、pment, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 61076-3-103 on 2004-02-01. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2004-11-01 l
18、atest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2007-02-01 Annex ZA has been added by CENELEC. _ Endorsement notice The text of the International Standard IEC 61076-3-103:2003 was approved by CENELEC as a European Standard without any modification. _ Pag
19、e 2 EN 610763103:2004 CONTENTS 1 General 7 1.1 Scope7 1.2 Recommended method of mounting.7 1.3 Ratings and characteristics7 1.4 Reference documents8 1.5 Marking .8 1.6 IEC type designation9 1.7 Ordering information10 2 Technical information10 2.1 Terminology.10 2.2 Survey of styles and variants for
20、fixed board connectors (XB).10 2.3 Survey of styles and variants for free cable connectors (EC) 10 2.4 Information on fixed board connector application10 3 Dimensional information .11 3.1 General .11 3.2 Isometric view and common features for fixed board connector (XB) 11 3.3 Isometric view and comm
21、on features for free cable connector (EC)19 3.4 Mating Information.23 3.5 Fixed board connector connectors interface dimensions.24 3.6 Free cable connectors interface dimensions.25 3.7 Mounting information for fixed board (XB) connectors 26 3.8 Panel mount information34 3.9 Mounting bracket.37 4 Cha
22、racteristics43 4.1 Climatic category.43 4.2 Electrical .43 4.3 Mechanical45 5 Test schedule.46 5.1 General .46 5.2 Test sequences .46 6 Quality assessment procedures 51 6.1 Qualification approval testing.51 6.2 Reinspection51 Annex A (normative) Eye pattern53 Annex B (normative) Characteristic imped
23、ance.57 Annex ZA (normative) Normative references to international publications with their corresponding European publications 59 Page 3 EN 610763103:2004 Figure 1 Isometric view fixed board connector (XB) right angle (version 1) (RR)11 Figure 2 Front view fixed board connector (XB) right angle (ver
24、sion 1) (RR)12 Figure 3 Top view fixed board connector (XB) right angle (version 1) (RR)12 Figure 4 Side view fixed board connector (XB) right angle (version 1) (RR).13 Figure 5 Isometric view fixed board connector (XB) right angle (version 2) bulkhead mount (RE) .13 Figure 6 Front view fixed board