BS-EN-61168-1994 BS-5724-3.129-1994 IEC-61168-1993.pdf
《BS-EN-61168-1994 BS-5724-3.129-1994 IEC-61168-1993.pdf》由会员分享,可在线阅读,更多相关《BS-EN-61168-1994 BS-5724-3.129-1994 IEC-61168-1993.pdf(26页珍藏版)》请在三一文库上搜索。
1、BRITISH STANDARD BS EN 61168:1994 BS 5724-3.129: 1994 IEC 1168:1993 Medical electrical equipment Part 3: Particular requirements for performance Section 3.129 Methods of declaring functional performance characteristics of radiotherapy simulators The European Standard EN 61168:1994 has the status of
2、a British Standard UDC 615.849:616-073.75:621.3:620.1 Licensed Copy: sheffieldun sheffieldun, na, Wed Nov 08 02:24:34 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS EN 61168:1994 This British Standard, having been prepared under the direction of the Health Care Standards Policy Committee, was publish
3、ed under the authority of the Standards Board and comes into effect on 15 June 1994 BSI 01-2000 The following BSI references relate to the work on this standard: Committee reference HCC 81 Draft for comment 92/52057 DC ISBN 0 580 23394 4 Cooperating organizations The European Committee for Standardi
4、zation (CEN), under whose supervision this European Standard was prepared, comprises the national standards organizations of the following countries: AustriaOesterreichisches Normungsinstitut BelgiumInstitut belge de normalisation DenmarkDansk Standardiseringsraad FinlandSuomen Standardisoimisliito,
5、 r.y. FranceAssociation franaise de normalisation GermanyDeutsches Institut fr Normung e.V. GreeceHellenic Organization for Standardization IcelandTechnological Institute of Iceland IrelandNational Standards Authority of Ireland ItalyEnte Nazionale Italiano di Unificazione LuxembourgInspection du Tr
6、avail et des Mines NetherlandsNederlands Normalisatie-instituut NorwayNorges Standardiseringsforbund PortugalInstituto Portugus da Qualidade SpainAsociacin Espaola de Normalizacin y Certificacin SwedenStandardiseringskommissionen i Sverige SwitzerlandAssociation suisse de normalisation United Kingdo
7、mBritish Standards Institution Amendments issued since publication Amd. No.DateComments Licensed Copy: sheffieldun sheffieldun, na, Wed Nov 08 02:24:34 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS EN 61168:1994 BSI 01-2000i Contents Page Cooperating organizationsInside front cover National foreword
8、ii Foreword2 Text of EN 611683 National annex NA (informative) Committees responsibleInside back cover National annex NB (informative) Cross-referencesInside back cover Licensed Copy: sheffieldun sheffieldun, na, Wed Nov 08 02:24:34 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS EN 61168:1994 ii BSI
9、01-2000 National foreword This British Standard has been prepared under the direction of the Health Care Standards Policy Committee and is the English language version of EN 61168:1994 Radiotherapy simulators Functional performance characteristics, published by the European Committee for Electrotech
10、nical Standardization (CENELEC). It is identical with IEC 1168:1993 Radiotherapy simulators Functional performance characteristics, published by the International Electrotechnical Commission (IEC). It is simultaneously published as BS 5724 Medical electrical equipment Section 3.129:1994 Methods of d
11、eclaring functional performance characteristics of radiotherapy simulators. This Particular Standard thus forms part of the group of standards directed specifically at electrical equipment used in health care. This Particular Standard details procedures by which the functional performance characteri
12、stics of radiotherapy simulators which use diagnostic X-ray equipment may be determined and specified. Guidance in the application of this standard is given in BS 5724-3.129:Supplement 1, which is published simultaneously. Annex A to this Particular Standard is for information only. Attention is dra
13、wn to BS 5724-2.129 which specifies the particular requirements for the safety of radiotherapy simulators. Additional information. The following print types are used in this standard. Requirements, compliance with which can be tested, and definitions: in roman type. Explanations, advice and general
14、statements: in small roman type. Terms defined in clause 2 of BS 5724-1, in clause 2 of BS 5724-2.129, in 3.2 of this Particular Standard and in BS 6641: SMALL CAPITALS. For the purposes of this British Standard, any references to IEC page numbers in the text should be ignored. Textual errors. When
15、adopting the text of the International Standard, the textual errors listed below were discovered. They have been marked in the text and have been reported to IEC in a proposal to amend the text of the International Standard. In Table 9, after “ISOCENTRE” in the last column heading, should be inserte
16、d: “when the table top rotation is set to 0”. The sentence immediately after Table 9 should be replaced by the following: “Half the difference of the instrument readings is equal to the angle of tilt of the table top rotation axis (5) relative to the ISOCENTRIC rotation axis (6) in the direction of
17、the line joining these two axes. Half the sum of the instrument readings is equal to the angle of tilt of the table top rotation axis (5) in the direction perpendicular to the line joining axes (5) and (6).” A British Standard does not purport to include all the necessary provisions of a contract. U
18、sers of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, the EN title page, pages 2 to 20, an i
19、nside back cover and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover. Licensed Copy: sheffieldun sheffieldun, na, Wed Nov 08 02:24:34 GMT+00:00 2006, Uncontrolled Copy,
20、 (c) BSI EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 61168 February 1994 UDC 615.849:616-073.75:621.3:620.1 Descriptors: Electromedical equipment, simulator, radiotherapy, functional performance values English version Radiotherapy simulators Functional performance characteristics (IEC 1168:
21、1993) Simulateurs de radiothrapie Caractristiques fonctionnelles (CEI 1168:1993) Strahlentherapie-Simulatoren Apparative Funktionsmerkmale (IEC 1168:1993) This European Standard was approved by CENELEC on 1992-12-09. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which
22、 stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European S
23、tandard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the na
24、tional electrotechnical committees of Austria, Belgium, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom. CENELEC European Committee for Electrotechnical Standardization Comit Europen de Norma
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS-EN-61168-1994 BS-5724-3.129-1994 IEC-61168-1993 BS EN 61168 1994 5724 3.129 IEC 1993