BS-ISO-17713-1-2007.pdf
《BS-ISO-17713-1-2007.pdf》由会员分享,可在线阅读,更多相关《BS-ISO-17713-1-2007.pdf(26页珍藏版)》请在三一文库上搜索。
1、BRITISH STANDARD BS ISO 17713-1:2007 Meteorology Wind measurements Part 1: Wind tunnel test methods for rotating anemometer performance ICS 07.060; 17.080 ? Licensed Copy: London South Bank University, London South Bank University, Fri Jun 01 01:33:07 GMT+00:00 2007, Uncontrolled Copy, (c) BSI BS IS
2、O 17713-1:2007 This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 May 2007 BSI 2007 ISBN 978 0 580 50835 6 National foreword This British Standard was published by BSI. It is the UK implementation of ISO 17713-1:2007. The UK participation in
3、its preparation was entrusted to Technical Committee EH/2, Air quality. A list of organizations represented on this committee can be obtained on request to its secretary. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct ap
4、plication. Compliance with a British Standard cannot confer immunity from legal obligations. Amendments issued since publication Amd. No. DateComments Licensed Copy: London South Bank University, London South Bank University, Fri Jun 01 01:33:07 GMT+00:00 2007, Uncontrolled Copy, (c) BSI Reference n
5、umber ISO 17713-1:2007(E) INTERNATIONAL STANDARD ISO 17713-1 First edition 2007-05-01 Meteorology Wind measurements Part 1: Wind tunnel test methods for rotating anemometer performance Mtorologie Mesurages du vent Partie 1: Mthodes dessai en soufflerie pour dterminer les caractristiques dun anmomtre
6、 tournant BS ISO 17713-1:2007 Licensed Copy: London South Bank University, London South Bank University, Fri Jun 01 01:33:07 GMT+00:00 2007, Uncontrolled Copy, (c) BSI ii Licensed Copy: London South Bank University, London South Bank University, Fri Jun 01 01:33:07 GMT+00:00 2007, Uncontrolled Copy,
7、 (c) BSI iii Contents Foreword iv Introduction v 1 Scope 1 2 Normative references1 3 Terms and definitions .1 4 Symbols and abbreviated terms 2 5 Summary of test method.3 6 Documentation.6 7 Apparatus .6 7.1 Measuring system6 7.2 Recording techniques.7 8 Test procedures.7 8.1 Starting threshold (U0)
8、 7 8.2 Transfer function ( = a + bR + )8 8.3 Distance constant (LU) 8 8.4 Off-axis response ratio (QU) Cup anemometers 9 8.5 Off-axis response ratio (QU) Vane-mounted propeller anemometers9 8.6 Off-axis response ratio (QU) Fixed-axis propeller anemometers.9 8.7 Acceptance testing10 9 Quality of the
9、test method 10 9.1 General10 9.2 Wind tunnel 10 9.3 Repeatability.10 9.4 Uncertainty.11 Annex A (normative) Wind tunnel standard test conditions 12 Annex B (informative) Examples of formats for recording run data14 Bibliography17 BS ISO 17713-1:2007 Licensed Copy: London South Bank University, Londo
10、n South Bank University, Fri Jun 01 01:33:07 GMT+00:00 2007, Uncontrolled Copy, (c) BSI iv Foreword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried o
11、ut through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO c
12、ollaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2. The main task of technical committees is to prepare International
13、 Standards. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote. Attention is drawn to the possibility that some of the elemen
14、ts of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. ISO 17713-1 was prepared by Technical Committee ISO/TC 146, Air quality, Subcommittee SC 5, Meteorology. ISO 17713 consists of the following parts, under the gene
15、ral title Meteorology Wind measurements: Part 1: Wind tunnel test methods for rotating anemometer performance The following part is planned: Part 2: Wind tunnel test methods for wind vanes BS ISO 17713-1:2007 Licensed Copy: London South Bank University, London South Bank University, Fri Jun 01 01:33
16、:07 GMT+00:00 2007, Uncontrolled Copy, (c) BSI v Introduction Cup and propeller anemometers are the most frequently used meteorological instruments for the measurement of mean wind speed in the near surface layer, that portion of the atmosphere which lies within a few tens of meters of the earths su
17、rface. Some types of cup and propeller anemometers are available for measuring wind speeds of a few tenths of a meter per second while other types can measure wind speeds approaching 100 ms1. These general purpose anemometers are used extensively for meteorology, aviation, air pollution, wind energy
18、 and numerous other applications. This part of ISO 17713 was developed in order to have a worldwide uniform set of test methods to define the characteristics of cup and propeller anemometers. This part of ISO 17713 will allow an end user to compare different manufacturers and different models of cup
19、 and propeller anemometers to determine the suitability for a particular application. BS ISO 17713-1:2007 Licensed Copy: London South Bank University, London South Bank University, Fri Jun 01 01:33:07 GMT+00:00 2007, Uncontrolled Copy, (c) BSI blank Licensed Copy: London South Bank University, Londo
20、n South Bank University, Fri Jun 01 01:33:07 GMT+00:00 2007, Uncontrolled Copy, (c) BSI 1 Meteorology Wind measurements Part 1: Wind tunnel test methods for rotating anemometer performance 1 Scope 1.1 This part of ISO 17713 describes wind tunnel test methods for determining performance characteristi
21、cs of rotating anemometers, specifically cup anemometers and propeller anemometers. 1.2 This part of ISO 17713 describes an acceptance test and unambiguous methods for measuring the starting threshold, distance constant, transfer function and off-axis response of a rotating anemometer in a wind tunn
22、el. Note that when transferring values determined by these methods to atmospheric flow, there is a difference between anemometer performance in the free atmosphere and in the wind tunnel. 2 Normative references The following referenced documents are indispensable for the application of this document
23、. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document applies. ISO 5725-1, Accuracy (trueness and precision) of measurement methods and results Part 1: General principles and definitions ISO 5725-2, Accuracy (trueness and precis
24、ion) of measurement methods and results Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. See also References 1, 2 and 3. 3.1 distance