BS-EN-55016-1-3-2006.pdf
《BS-EN-55016-1-3-2006.pdf》由会员分享,可在线阅读,更多相关《BS-EN-55016-1-3-2006.pdf(36页珍藏版)》请在三一文库上搜索。
1、BRITISH STANDARD BS EN 55016-1-3:2006 Specification for radio disturbance and immunity measuring apparatus and methods Part 1-3: Radio disturbance and immunity measuring apparatus Ancillary equipment Disturbance power The European Standard EN 55016-1-3:2006 has the status of a British Standard ICS 3
2、3.100.10; 33.100.20 ? Licensed Copy: London South Bank University, London South Bank University, Thu Jan 18 01:09:03 GMT+00:00 2007, Uncontrolled Copy, (c) BSI BS EN 55016-1-3:2006 This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 January 20
3、07 BSI 2007 ISBN 978-0-580-50002-2 National foreword This British Standard was published by BSI. It is the UK implementation of EN 55016-1-3:2006. It is identical with CISPR 16-1-3:2004. It supersedes BS EN 55016-1-3:2004, which will be withdrawn on 1 July 2009. The UK participation in its preparati
4、on was entrusted by Technical Committee GEL/210, EMC Policy committee, to Subcommittee GEL/210/12, EMC Basic and generic standards. A list of organizations represented on GEL/210/12 can be obtained on request to its secretary. This publication does not purport to include all the necessary provisions
5、 of a contract. Users are responsible for its correct application. Compliance with a British Standard cannot confer immunity from legal obligations. Amendments issued since publication Amd. No. DateComments Licensed Copy: London South Bank University, London South Bank University, Thu Jan 18 01:09:0
6、3 GMT+00:00 2007, Uncontrolled Copy, (c) BSI EUROPEAN STANDARD EN 55016-1-3 NORME EUROPENNE EUROPISCHE NORM November 2006 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretari
7、at: rue de Stassart 35, B - 1050 Brussels 2006 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 55016-1-3:2006 E ICS 33.100.10;33.100.20 Supersedes EN 55016-1-3:2004 English version Specification for radio disturbance and immunity
8、measuring apparatus and methods Part 1-3: Radio disturbance and immunity measuring apparatus - Ancillary equipment - Disturbance power (CISPR 16-1-3:2004) Spcifications des mthodes et des appareils de mesure des perturbations radiolectriques et de limmunit aux perturbations radiolectriques Partie 1-
9、3: Appareils de mesure des perturbations radiolectriques et de limmunit aux perturbations radiolectriques - Matriels auxiliaires - Puissance perturbatrice (CISPR 16-1-3:2004) Anforderungen an Gerte und Einrichtungen sowie Festlegung der Verfahren zur Messung der hochfrequenten Straussendung (Funkstr
10、ungen) und Strfestigkeit Teil 1-3: Gerte und Einrichtungen zur Messung der hochfrequenten Straussendung (Funkstrungen) und Strfestigkeit - Zusatz-/Hilfseinrichtungen - Strleistungsmessung (CISPR 16-1-3:2004) This European Standard was approved by CENELEC on 2006-07-01. CENELEC members are bound to c
11、omply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central
12、Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status
13、 as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portug
14、al, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. Licensed Copy: London South Bank University, London South Bank University, Thu Jan 18 01:09:03 GMT+00:00 2007, Uncontrolled Copy, (c) BSI Foreword The text of the International Standard CISPR 16-1-3:2004, prepared by
15、 CISPR SC A, Radio-interference measurements and statistical methods, was submitted to the CENELEC Unique Acceptance Procedure and was approved by CENELEC as EN 55016-1-3 on 2006-07-01. This European Standard supersedes EN 55016-1-3:2004. In this EN 55016-1-3:2006, a more detailed calibration method
16、 for the absorbing clamp is specified. Furthermore, new alternative calibration methods are introduced which are more practicable than the one that was specified previously. Additional parameters to describe the absorbing clamp are defined, like the decoupling factor for the broadband absorber (DF)
17、and the decoupling factor for the current transformer (DR), along with their validation methods. A procedure for the validation of the absorbing clamp test site (ACTS) is also included in the document. The following dates were fixed: ? latest date by which the EN has to be implemented at national le
18、vel by publication of an identical national standard or by endorsement (dop) 2007-07-01 ? latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2009-07-01 Annex ZA has been added by CENELEC. _ Endorsement notice The text of the International Standard CISPR 16
19、-1-3:2004, including the corrigendum February 2006, was approved by CENELEC as a European Standard without any modification. _ 2 EN 55016-1-3:2006 Licensed Copy: London South Bank University, London South Bank University, Thu Jan 18 01:09:03 GMT+00:00 2007, Uncontrolled Copy, (c) BSI CONTENTS 3 Anne
20、x B (normative) Calibration and validation methods for the absorbing clamp and Figure 1 Overview of the absorbing clamp measurement method and the associated Figure C.1 Test set-ups for the site attenuation measurement for clamp site Table 1 Overview of the characteristics of the three-clamp calibra
21、tion methods and 3 EN 55016-1-3:2006 1 Scope.4 2 Normative references .4 Terms, definitions and abbreviations 4 4 Absorbing clamp instrumentation5 Annex A (informative) Construction of the absorbing clamp (Subclause 4.2) 17 calibration and validation procedures13 Figure 2 Schematic overview of the a
22、bsorbing clamp test method15 Figure 3 Schematic overview of the clamp calibration methods16 Figure A.1 The absorbing clamp assembly and its parts.17 Figure A.2 Example of the construction of an absorbing clamp.18 Figure B.1 The original calibration site.25 Figure B.2 Position of guide for centering
23、the lead under test 25 Figure B.3 Side view of the calibration jig .26 Figure B.4 Top view of the jig 26 Figure B.5 View of the jigs vertical flange 26 Figure B.6 Test set-up for the reference device calibration method 27 Figure B.7 Specification of the reference device 27 Figure B.8 Measurement set
24、-up of the decoupling factor DF 28 Figure B.9 Measurement set-up of the decoupling factor DR28 validation using the reference device 31 their relation .14 the secondary absorbing device (Clause 4).19 Annex C (normative) Validation of the absorbing clamp test site (Clause 4).29 Annex ZA (normative) N
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS EN 55016 2006
链接地址:https://www.31doc.com/p-3748942.html