BS-EN-60068-3-5-2002 IEC-60068-3-5-2001.pdf
《BS-EN-60068-3-5-2002 IEC-60068-3-5-2001.pdf》由会员分享,可在线阅读,更多相关《BS-EN-60068-3-5-2002 IEC-60068-3-5-2001.pdf(16页珍藏版)》请在三一文库上搜索。
1、BRITISH STANDARD BS EN 60068-3-5:2002 IEC 60068-3-5:2001 Environmental testing Part 3-5: Supporting documentation and guidance Confirmation of the performance of temperature chambers The European Standard EN 60068-3-5:2002 has the status of a British Standard ICS 19.040; 19.080 NO COPYING WITHOUT BS
2、I PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW BS EN 60068-3-5:2002 This British Standard, having been prepared under the direction of the Electrotechnical Sector Policy and Strategy Committee, was published under the authority of the Standards Policy and Strategy Committee on 5 March 2002 BSI 5
3、March 2002 ISBN 0 580 39049 7 National foreword This British Standard is the official English language version of EN 60068-3-5:2002. It is identical with IEC 60068-3-5:2001. The UK participation in its preparation was entrusted to Technical Committee GEL/104, Environmental conditions, classification
4、 and testing, which has the responsibility to: A list of organizations represented on this committee can be obtained on request to its secretary. From 1 January 1997, all IEC publications have the number 60000 added to the old number. For instance, IEC 27 has been renumbered as IEC 60027-1. For a pe
5、riod of time during the change over from one numbering system to the other, publications may contain identifiers from both systems. Cross-references The British Standards which implement these international or European publications may be found in the BSI Standards Catalogue under the section entitl
6、ed “International Standards Correspondence Index”, or by using the “Find” facility of the BSI Standards Electronic Catalogue. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Complianc
7、e with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the text; present to the responsible European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and
8、 European developments and promulgate them in the UK. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 12, an inside back cover and a back cover. The BSI copyright date displayed in this document indicates when the document was last issued.
9、 Amendments issued since publication Amd. No. DateComments EUROPEAN STANDARDEN 60068-3-5 NORME EUROPENNE EUROPISCHE NORMJanuary 2002 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Centra
10、l Secretariat: rue de Stassart 35, B - 1050 Brussels 2002 CENELEC -All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 60068-3-5:2002 E ICS 19.040; 29.020 English version Environmental testing Part 3-5: Supporting documentation and guidance Con
11、firmation of the performance of temperature chambers (IEC 60068-3-5:2001) Essais denvironnement Partie 3-5: Documentation daccompagnement et guide - Confirmation des performances des chambres dessai en temprature (CEI 60068-3-5:2001) Umweltprfungen Teil 3-5: Untersttzende Dokumentation und Leitfaden
12、 Besttigung des Leistungvermgens von Temperaturprfkammern (IEC 60068-3-5:2001) This European Standard was approved by CENELEC on 2001-12-04. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a
13、national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A versi
14、on in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Republic, Denm
15、ark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom. EN 60068-3-5:2002- 2 - Foreword The text of document 104/209/FDIS, future edition 1 of IEC 60068-3-5, prepared by IEC TC 104, Environmental
16、 conditions, classification and methods of test, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 60068-3-5 on 2001-12-04. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national stand
17、ard or by endorsement(dop) 2002-09-01 latest date by which the national standards conflicting with the EN have to be withdrawn(dow) 2004-12-01 This European Standard should be read in conjunction with EN 60068-3-6 and EN 60068-3-7. Annexes designated “normative“ are part of the body of the standard.
18、 In this standard, annex ZA is normative Annex ZA has been added by CENELEC. _ Endorsement notice The text of the International Standard IEC 60068-3-5:2001 was approved by CENELEC as a European Standard without any modification. _ Page 2 EN 6006835:2002 BSI 5 March 2002 60068-3-5 IEC:2001 3 CONTENTS
19、 INTRODUCTION 4 1Scope 5 2Normative references. 5 3Definitions 5 4Measuring chamber performances . 8 4.1Test area environment 8 4.2Temperature measurement system . 8 4.3Temperature chamber test load. 8 4.4Installation of temperature sensors 8 4.5Determination of temperature performance . 9 5Standard
20、 temperature sequence10 6Evaluation criteria .11 7Information to be given in the performance test report .11 Figure 1 Working space. 6 Figure 2 Example of temperature differences. 7 Figure 3 Location of air temperature sensors for temperature chambers up to 2000 l. 9 Figure 4 Location of minimal add
21、itional air temperature sensors for temperature chambers over 2000 l. 9 Figure 5 Temperature rate of change for heating and cooling of a test chamber 10 Annex ZA (normative) Normative references to international publications with their corresponding European Publications 12 Page 3 EN 6006835:2002 BS
22、I 5 March 2002 60068-3-5 IEC:2001 4 INTRODUCTION IEC 60068 contains fundamental information on environmental testing procedures and severities. The expression “environmental conditioning“ or “environmental testing“ covers the natural and artificial environments to which components or equipment may b
23、e exposed so that an assessment can be made of their performance under conditions of use, transport and storage to which they may be exposed in practice. Temperature chambers used for “environmental conditioning“ or “environmental testing“ are not described in any publication, although the method of
24、 maintaining and measuring temperature and/or humidity has a great influence on test results. The physical characteristics of temperature chambers can also influence test results. Page 4 EN 6006835:2002 BSI 5 March 2002 60068-3-5 IEC:2001 5 ENVIRONMENTAL TESTING Part 3-5: Supporting documentation an
- 配套讲稿: