BS-EN-62395-1-2006.pdf
《BS-EN-62395-1-2006.pdf》由会员分享,可在线阅读,更多相关《BS-EN-62395-1-2006.pdf(34页珍藏版)》请在三一文库上搜索。
1、BRITISH STANDARD BS EN 62395-1:2006 Electrical resistance trace heating systems for industrial and commercial applications Part 1: General and testing requirements The European Standard EN 62395-1:2006 has the status of a British Standard ICS 25.180.10 ? BS EN 62395-1:2006 This British Standard was
2、published under the authority of the Standards Policy and Strategy Committee on 31 October 2006 BSI 2006 ISBN 0 580 49341 5 National foreword This British Standard was published by BSI. It is the UK implementation of EN 62395-1:2006. It is identical with IEC 62395-1:2006. The UK participation in its
3、 preparation was entrusted to Technical Committee PEL/27, Electroheating. A list of organizations represented on PEL/27 can be obtained on request to its secretary. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct applicat
4、ion. Compliance with a British Standard cannot confer immunity from legal obligations. Amendments issued since publication Amd. No. DateComments EUROPEAN STANDARD EN 62395-1 NORME EUROPENNE EUROPISCHE NORM September 2006 CENELEC European Committee for Electrotechnical Standardization Comit Europen d
5、e Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2006 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 62395-1:2006 E ICS 25.180.10 English
6、 version Electrical resistance trace heating systems for industrial and commercial applications Part 1: General and testing requirements (IEC 62395-1:2006) Systmes de traage par rsistance lectrique pour applications industrielles et commerciales Partie 1: Exigences gnrales et dessai (CEI 62395-1:200
7、6) Elektrische Begleitheizungen Trace-Widerstandsheizungen fr industrielle und gewerbliche Zwecke Teil 1: Allgemeine Anforderungen und Prfanforderungen (IEC 62395-1:2006) This European Standard was approved by CENELEC on 2006-09-01. CENELEC members are bound to comply with the CEN/CENELEC Internal R
8、egulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member.
9、 This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC me
10、mbers are the national electrotechnical committees of Austria, Belgium, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spai
11、n, Sweden, Switzerland and the United Kingdom. EN 62395-1:2006 2 Foreword The text of document 27/533/FDIS, future edition 1 of IEC 62395-1, prepared by IEC TC 27, Industrial electroheating equipment, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 62395-1 on 2006-09
12、-01. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2007-06-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2009-09-01 Annex
13、 ZA has been added by CENELEC. _ Endorsement notice The text of the International Standard IEC 62395-1:2006 was approved by CENELEC as a European Standard without any modification. _ 3 EN 62395-1:2006 CONTENTS INTRODUCTION.4 1 Scope and object5 2 Normative references .6 3 Terms and definitions .6 4
14、General requirements .11 4.1 General.11 4.2 Metallic braids or sheaths 11 4.3 Electrical circuit protection requirements for branch circuits11 4.4 Control and temperature requirements .12 5 Testing.12 5.1 Type tests General .12 5.2 Type tests .12 5.3 Type tests Additional tests for outdoor exposed a
15、rea installations without thermal insulation 25 5.4 Type tests Additional tests for installations with embedded trace heater.27 5.5 Type tests Additional tests for installations with trace heater inside conduit or piping27 5.6 Routine tests .28 6 Marking28 6.1 General.28 6.2 Product markings.28 6.3
16、Markings for field-assembled components29 7 Installation instructions .29 Annex ZA (normative) Normative references to international publications with their corresponding European publications31 Bibliography .30 Figure 1 Flammability test 15 Figure 2 Impact test .16 Figure 3 Cold bend test18 Figure
17、4 Moisture resistance test19 Figure 5 Verification of rated output21 Figure 6 Verification of sheath temperature using system approach 23 Figure 7 Maximum sheath temperature using the product classification approach24 Figure 8 Abrasion test27 Table 1 Test voltages for the dielectric test.13 EN 62395
18、-1:2006 4 INTRODUCTION IEC 62395-1 provides the essential requirements and testing appropriate to electrical resistance trace heating equipment used in industrial and commercial applications. While some of this work already exists in national or international standards, this standard has collated mu
19、ch of this existing work and added considerably to it. IEC/TS 62395-2 provides detailed recommendations for the system design, installation and maintenance of electric trace heating systems in industrial and commercial applications. It is the objective of IEC 62395 that, when in normal use, electric
20、al trace heating systems should operate safely under their defined conditions of use, by a) employing heaters of the appropriate construction and meeting the test criteria detailed in Part 1. The construction should include a metallic sheath, braid, screen or equivalent electrically conductive cover
21、ing; b) operating at safe temperatures when designed, installed, and maintained in accordance with Part 2; c) having at least the minimum levels of overcurrent and ground fault protection recommended in Part 2. Some tests of Part 1 differ from similar tests developed by TC 20 and are to be reviewed
22、in the future. These and other tests are almost identical to the tests given in IEC 62086-1:20011 and are duplicated in Part 1 for completeness (see notes in the text). 1 Permission to reproduce the text of several tests from IEC 62086-1:2001 that are not specific to explosive gas atmospheres has be
23、en granted by TC 31. 5 EN 62395-1:2006 ELECTRICAL RESISTANCE TRACE HEATING SYSTEMS FOR INDUSTRIAL AND COMMERCIAL APPLICATIONS Part 1: General and testing requirements 1 Scope and object This part of IEC 62395 specifies requirements for electrical resistance trace heating systems and includes general
24、 test requirements. This standard pertains to trace heating systems that may comprise either factory-fabricated or field-assembled (work-site) units, and which may be series heater cables, parallel heater cables, heater pads or heater panels that have been assembled and/or terminated in accordance w