CEA-2002-A-2009.pdf
《CEA-2002-A-2009.pdf》由会员分享,可在线阅读,更多相关《CEA-2002-A-2009.pdf(65页珍藏版)》请在三一文库上搜索。
1、 CEA Standard Test Procedure for Powerline Carrier Technology CEA-2002-A February 2009 Copyright Consumer Electronics Association Provided by IHS under license with CEA Licensee=HP Monitoring/1111111164 Not for Resale, 04/07/2009 03:48:05 MDTNo reproduction or networking permitted without license fr
2、om IHS -,-,- NOTICE Consumer Electronics Association (CEA) Standards, Bulletins and other technical publications are designed to serve the public interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assi
3、sting the purchaser in selecting and obtaining with minimum delay the proper product for his particular need. Existence of such Standards, Bulletins and other technical publications shall not in any respect preclude any member or nonmember of CEA from manufacturing or selling products not conforming
4、 to such Standards, Bulletins or other technical publications, nor shall the existence of such Standards, Bulletins and other technical publications preclude their voluntary use by those other than CEA members, whether the standard is to be used either domestically or internationally. Standards, Bul
5、letins and other technical publications are adopted by CEA in accordance with the American National Standards Institute (ANSI) patent policy. By such action, CEA does not assume any liability to any patent owner, nor does it assume any obligation whatever to parties adopting the Standard, Bulletin o
6、r other technical publication. This CEA Standard is considered to have International Standardization implication, but the International Electrotechnical Commission activity has not progressed to the point where a valid comparison between the CEA Standard and the IEC document can be made. This Standa
7、rd does not purport to address all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of the user of this Standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations before its use
8、. (Formulated under the cognizance of the CEAs R7 Home Network Committee.) Published by CONSUMER ELECTRONICS ASSOCIATION 2009 Technology second, operational data; and third, the method and ease with which a software/firmware field upgrade can be effected. 8.6.2 Test Procedure 8.6.2.1 Demonstration o
9、f Features Observed (Static Device Information) Demonstrate the following features: Serial number Manufacturer name Version information Network ID (MAC address) Record the overall manageability 8.6.2.2 Demonstration of Features Observed (Dynamic Device Interaction) Demonstrate the following features
10、: Operational status: Off-Online Link status Active node list (i.e., attached to the network, even if they are idle) Counters: Packet counter Record the overall manageability. 8.6.2.3 Demonstration of Features Observed (Device Specific) Demonstrate software/firmware upgrade method, i.e., show how te
11、chnology is field upgradeable. Record the overall manageability. Copyright Consumer Electronics Association Provided by IHS under license with CEA Licensee=HP Monitoring/1111111164 Not for Resale, 04/07/2009 03:48:05 MDTNo reproduction or networking permitted without license from IHS -,-,- CEA-2002-
12、A 35 8.7 In-House Compatibility 8.7.1 Description Existing low-speed powerline technologies should continue to operate in the presence of the PLT under test. Additionally, the existing powerline technologies should not impair the operation of the PLT under test. Specifically, the following three low
13、-speed powerline technology standards will be tested: EIA-709, X-10, and EIA-600. 8.7.2 Test Procedure 8.7.2.1 Coexistence With EIA-709, X-10, And EIA-600 Select four outlets that are close to each other (so that interference between the high- speed and low-speed powerline technologies is realistica
14、lly high). 8.7.2.2 Test procedure 8.7.2.2.1 High speed powerline baseline test Start a bi-directional FTP between the two high speed powerline nodes for 30 seconds, with the nodes connected in outlets 1 and 2 and with all the other nodes disconnected. Record performance, including FTP throughput and
15、 packet loss rate. 8.7.2.2.2 EIA-709 baseline test Start a bi-directional data transmission (type of transmission will be dependant on the capabilities of the nodes) between the two EIA-709 nodes for 30 seconds, with the nodes connected in outlets 3 and 4 and with all the other nodes disconnected. R
16、ecord performance, including throughput and packet loss rate. 8.7.2.2.3 X-10 baseline test Start a bi-directional data transmission (type of transmission will be dependant on the capabilities of the nodes) between the two X-10 nodes for 30 seconds, with the nodes connected in outlets 3 and 4 and wit
17、h all the other nodes disconnected. Record performance, including triggering, throughput and packet loss rate. 8.7.2.2.4 EIA-600 baseline test Start a bi-directional data transmission (type of transmission will be dependant on the capabilities of the nodes) between the two EIA-600 nodes for 30 secon
18、ds, with the nodes connected in outlets 3 and 4 and with all the other nodes disconnected. Record performance, including data throughput and packet loss rate. 8.7.2.2.5 Interference with EIA-709 test Connect the high speed powerline nodes in outlets 1 and 2. Connect EIA-709 nodes in outlets 3 and 4.
19、 Start a bi-directional FTP between outlets 1 and 2. Start data transmission between outlets 3 and 4. Record FTP throughput and packet loss rate. Record performance, including data throughput and packet loss rate for EIA-709 nodes. 8.7.2.2.6 Interference with X-10 test Connect the high speed powerli
20、ne nodes in outlets 1 and 2. Connect X-10 nodes in outlets 3 and 4. Start a bi-directional FTP between outlets 1 and 2. Start data transmission between outlets 3 and 4. Record FTP throughput and packet loss rate. Record performance, including triggering, false triggering, data throughput and packet
21、loss rate for X-10 nodes. 8.7.2.2.7 Interference with EIA-600 test Connect the high speed powerline nodes in outlets 1 and 2. Connect EIA-600 nodes in outlets 3 and 4. Start a bi-directional FTP between outlets 1 and 2. Start data transmission between outlets 3 and 4. Record FTP throughput and packe
22、t loss rate. Record data throughput and packet loss rate for EIA-600 nodes. Copyright Consumer Electronics Association Provided by IHS under license with CEA Licensee=HP Monitoring/1111111164 Not for Resale, 04/07/2009 03:48:05 MDTNo reproduction or networking permitted without license from IHS -,-,
23、- CEA-2002-A 36 8.8 Extensibility (Optional) 8.8.1 Description The purpose of this test is to evaluate that technology under consideration is extensible to data rates exceeding 20 Mbps in the next generation. Although many vendors will not have next generation prototypes available for testing (and t
24、heir extensibility will have to be evaluated based on the technologies documentation), vendors that have next generation prototypes have the option of demonstrating extensibility on lab tests. 8.8.2 Scalability To 20 Mbps Or Greater 8.8.2.1 Test setup Connect two next-generation nodes in a power str