ETSI EN-300-019-1-6-2003.pdf
《ETSI EN-300-019-1-6-2003.pdf》由会员分享,可在线阅读,更多相关《ETSI EN-300-019-1-6-2003.pdf(11页珍藏版)》请在三一文库上搜索。
1、 ETSI EN 300 019-1-6 V2.1.4 (2003-04) European Standard (Telecommunications series) Environmental Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 1-6: Classification of environmental conditions; Ship environments ETSI ETSI EN 300 019-1-6 V2.1
2、.4 (2003-04) 2 Reference REN/EE-01027-1-62 Keywords equipment practice, environment, maritime, mobility, testing ETSI 650 Route des Lucioles F-06921 Sophia Antipolis Cedex - FRANCE Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16 Siret N 348 623 562 00017 - NAF 742 C Association but non lucratif enreg
3、istre la Sous-Prfecture de Grasse (06) N 7803/88 Important notice Individual copies of the present document can be downloaded from: http:/www.etsi.org The present document may be made available in more than one electronic version or in print. In any case of existing or perceived difference in conten
4、ts between such versions, the reference version is the Portable Document Format (PDF). In case of dispute, the reference shall be the printing on ETSI printers of the PDF version kept on a specific network drive within ETSI Secretariat. Users of the present document should be aware that the document
5、 may be subject to revision or change of status. Information on the current status of this and other ETSI documents is available at http:/portal.etsi.org/tb/status/status.asp If you find errors in the present document, send your comment to: editoretsi.org Copyright Notification No part may be reprod
6、uced except as authorized by written permission. The copyright and the foregoing restriction extend to reproduction in all media. European Telecommunications Standards Institute 2003. All rights reserved. DECTTM, PLUGTESTSTM and UMTSTM are Trade Marks of ETSI registered for the benefit of its Member
7、s. TIPHONTM and the TIPHON logo are Trade Marks currently being registered by ETSI for the benefit of its Members. 3GPPTM is a Trade Mark of ETSI registered for the benefit of its Members and of the 3GPP Organizational Partners. ETSI ETSI EN 300 019-1-6 V2.1.4 (2003-04) 3 Contents Intellectual Prope
8、rty Rights4 Foreword.4 1 Scope5 2 References5 3 Definitions5 4 Environmental classes6 4.1 Class 6.1: totally weatherprotected locations .6 4.2 Class 6.2: partly weatherprotected locations6 4.3 Class 6.3: non-weatherprotected locations.7 5 Environmental conditions.8 5.1 Climatic conditions.8 5.2 Biol
9、ogical conditions8 5.3 Chemically active substances.9 5.4 Mechanically active substances9 5.5 Mechanical conditions10 History11 ETSI ETSI EN 300 019-1-6 V2.1.4 (2003-04) 4 Intellectual Property Rights IPRs essential or potentially essential to the present document may have been declared to ETSI. The
10、 information pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found in ETSI SR 000 314: “Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in respect of ETSI standards“, which is available fro
11、m the ETSI Secretariat. Latest updates are available on the ETSI Web server (http:/webapp.etsi.org/IPR/home.asp). All published ETSI deliverables shall include information which directs the reader to the above source of information. Foreword This European Standard (Telecommunications series) has bee
12、n produced by ETSI Technical Committee Environmental Engineering (EE). The present document is part 1, sub-part 6 of a multi-part deliverable covering the classification of environmental conditions and environmental tests for telecommunications equipment, as identified below: Part 1: “Classification
13、 of environmental conditions“; Sub-part 0: “Introduction“; Sub-part 1: “Storage“; Sub-part 2: “Transportation“; Sub-part 3: “Stationary use at weatherprotected locations“; Sub-part 4: “Stationary use at non-weatherprotected locations“; Sub-part 5: “Ground vehicle installations“; Sub-part 6: “Ship en
14、vironments“; Sub-part 7: “Portable and non-stationary use“; Sub-part 8: “Stationary use at underground locations“; Part 2: “Specification of environmental tests“. Part 1 specifies different standardized environmental classes covering climatic and biological conditions, chemically and mechanically ac
15、tive substances and mechanical conditions during storage, transportation and in use. Part 1-0 forms a general overview of part 1. Part 2 specifies the recommended test severities and test methods for the different environmental classes. National transposition dates Date of latest announcement of thi
16、s EN (doa): 31 July 2003 Date of latest publication of new National Standard or endorsement of this EN (dop/e): 31 January 2004 Date of withdrawal of any conflicting National Standard (dow): 31 January 2004 ETSI ETSI EN 300 019-1-6 V2.1.4 (2003-04) 5 1 Scope The present document defines classes of e
17、nvironmental conditions and their severities to which telecommunication equipment may be exposed. The severities specified are those which will have a low probability of being exceeded; generally less than 1 %. The present document applies to equipment designed principally for maritime use. Conditio
18、ns of use vary significantly in relation to the size of the vessel and the function for which it was designed. The reader should ensure that the relevant classes are chosen to suit this particular application. The present document covers the following types of vessel: - vessel propelled by mechanica
19、l means, including offshore units; - vessel not propelled by mechanical means, including sailing boats and life rafts. The classes defined apply to all sizes of vessel from pleasure craft to trawlers, ferry boats, icebreakers and cargo ships including tankers. 2 References The following documents co
20、ntain provisions which, through reference in this text, constitute provisions of the present document. References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For a specific reference, subsequent revisions do not apply. For a non-sp
21、ecific reference, the latest version applies. Referenced documents which are not found to be publicly available in the expected location might be found at http:/docbox.etsi.org/Reference. 1 ETSI ETR 035: “Equipment Engineering (EE); Environmental engineering Guidance and terminology“. 2 IEC 60721-3-
22、6: “Classification of environmental conditions. Part 3: Classification of groups of environmental parameters and their severities. Ship environment“. 3 IEC 60721-2-1: “Classification of environmental conditions. Part 2: Environmental conditions appearing in nature. Temperature and humidity“. 4 IEC 6
23、0068-2-27: “Environmental testing. Part 2: Tests. Test Ea and guidance: Shock“. 5 IEC 60092-502: “Electrical installations in ships - Part 502: Tankers - Special features“. 6 ISO 2041: “Vibration and shock - Vocabulary“. 3 Definitions For the purposes of the present document, the following terms and
24、 definitions apply: absolute humidity: mass of water vapour in grammes which is associated with one cubic metre of dry air in an air/water vapour mixture non-weatherprotected location: location at which the equipment is not protected from direct weather influences relative humidity: ratio of the par